Searcharxiv⌕ Search

arXiv subjects

L. Dumoulin

Publications and source records attributed to L. Dumoulin.

At least 73 records · Page 4Linked to original sources

Electron glass effects in amorphous NbSi films

We report on non equilibrium field effect in insulating amorphous NbSi thin films having different Nb contents and thicknesses. The hallmark of an electron glass, namely the logarithmic growth of a memory dip in conductance versus gate voltage curves, is observed in all the films after a cooling from room temperature to 4.2 K. A very rich phenomenology is demonstrated. While the memory dip width is found to strongly vary with the film parameters, as was also observed in amorphous indium oxide films, screening lengths and temperature dependence of the dynamics are closer to what is observed in granular Al films. Our results demonstrate that the differentiation between continuous and discontinuous systems is not relevant to understand the discrepancies reported between various systems in the electron glass features. We suggest instead that they are not of fundamental nature and stem from differences in the protocols used and in the electrical inhomogeneity length scales within each material.

cond-mat.dis-nn↗

The CROSS Experiment: Rejecting Surface Events by PSD Induced by Superconducting Films

Neutrinoless double beta ($0νββ$) decay is a hypothetical rare nuclear transition ($T_{1/2}>10^{26}$ y). Its observation would provide an important insight about the nature of neutrinos (Dirac or Majorana particle) demonstrating that the lepton number is not conserved. This decay can be investigated with bolometers embedding the double beta decay isotope ($^{76}$Ge, $^{82}$Se, $^{100}$Mo, $^{116}$Cd, $^{130}$Te...), which perform as low temperature calorimeters (10 mK) detecting particle interactions via a small temperature rise read out by a dedicated thermometer. CROSS (Cryogenic Rare-event Observatory with Surface Sensitivity) aims at the development of bolometric detectors (Li$_{2}$MoO$_{4}$ and TeO$_{2}$) capable of discriminating surface $α$ and $β$ interactions by exploiting superconducting properties of Al film deposited on the crystal surface. We report in this paper the results of tests on prototypes performed at CSNSM (Orsay, France) that showed the capability of a-few-$μ$m-thick superconducting Al film deposited on crystal surface to discriminate surface $α$ from bulk events, thus providing the detector with the required surface sensitivity capability. The CROSS technology would further improve the background suppression and simplify the detector construction with a view to future competitive double beta decay searches.

physics.ins-det↗

QUBIC: the Q & U Bolometric Interferometer for Cosmology

The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addresses these requirements using an innovative approach combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with the deep control of systematics characteristic of interferometers. This makes QUBIC unique with respect to others classical imagers experiments devoted to the CMB polarization. In this contribution we report a description of the QUBIC instrument including recent achievements and the demonstration of the bolometric interferometry performed in lab. QUBIC will be deployed at the observation site in Alto Chorrillos, in Argentina at the end of 2019.

astro-ph.IM↗

Precise measurement of $2νββ$ decay of $^{100}$Mo with the CUPID-Mo detection technology

We report the measurement of the two-neutrino double-beta ($2νββ$) decay of $^{100}$Mo to the ground state of $^{100}$Ru using lithium molybdate (\crystal) scintillating bolometers. The detectors were developed for the CUPID-Mo program and operated at the EDELWEISS-III low background facility in the Modane underground laboratory. From a total exposure of $42.235$ kg$\times$d, the half-life of $^{100}$Mo is determined to be $T_{1/2}^{2ν}=[7.12^{+0.18}_{-0.14}\,\mathrm{(stat.)}\pm0.10\,\mathrm{(syst.)}]\times10^{18}$ years. This is the most accurate determination of the $2νββ$ half-life of $^{100}$Mo to date. We also confirm, with the statistical significance of $>3σ$, that the single-state dominance model of the $2νββ$ decay of $^{100}$Mo is favored over the high-state dominance model.

nucl-ex↗

QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB

QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detectors. QUBIC will be deployed in Argentina, at the Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta province. The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors (TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at 1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K allowing to reach an unprecedented multiplexing (MUX) factor equal to 128. The QUBIC experiment is currently being characterized in the lab with a reduced number of detectors before upgrading to the full instrument. I will present the last results of this characterization phase with a focus on the detectors and readout system.

astro-ph.IM↗

First data from the CUPID-Mo neutrinoless double beta decay experiment

The CUPID-Mo experiment is searching for neutrinoless double beta decay in $^{100}$Mo, evaluating the technology of cryogenic scintillating Li$_{2}^{100}$MoO$_4$ detectors for CUPID (CUORE Upgrade with Particle ID). CUPID-Mo detectors feature background suppression using a dual-readout scheme with Li$_{2}$MoO$_4$ crystals complemented by Ge bolometers for light detection. The detection of both heat and scintillation light signals allows the efficient discrimination of $α$ from $γ$&$β$ events. In this proceedings, we discuss results from the first 2 months of data taking in spring 2019. In addition to an excellent bolometric performance of 6.7$\,$keV (FWHM) at 2615$\,$keV and an $α$ separation of better than 99.9\% for all detectors, we report on bulk radiopurity for Th and U. Finally, we interpret the accumulated physics data in terms of a limit of $T_{1/2}^{0ν}\,> 3\times10^{23}\,$yr for $^{100}$Mo and discuss the sensitivity of CUPID-Mo until the expected end of physics data taking in early 2020.

hep-ex↗

The $0\nu2β$-decay CROSS experiment: preliminary results and prospects

Neutrinoless double-beta decay is a key process in particle physics. Its experimental investigation is the only viable method that can establish the Majorana nature of neutrinos, providing at the same time a sensitive inclusive test of lepton number violation. CROSS (Cryogenic Rare-event Observatory with Surface Sensitivity) aims at developing and testing a new bolometric technology to be applied to future large-scale experiments searching for neutrinoless double-beta decay of the promising nuclei $^{100}$Mo and $^{130}$Te. The limiting factor in large-scale bolometric searches for this rare process is the background induced by surface radioactive contamination, as shown by the results of the CUORE experiment. The basic concept of CROSS consists of rejecting this challenging background component by pulse-shape discrimination, assisted by a proper coating of the faces of the crystal containing the isotope of interest and serving as energy absorber of the bolometric detector. In this paper, we demonstrate that ultra-pure superconductive Al films deposited on the crystal surfaces act successfully as pulse-shape modifiers, both with fast and slow phonon sensors. Rejection factors higher than 99.9% of $α$ surface radioactivity have been demonstrated in a series of prototypes based on crystals of Li$_2$MoO$_4$ and TeO$_2$. We have also shown that point-like energy depositions can be identified up to a distance of $\sim 1$ mm from the coated surface. The present program envisions an intermediate experiment to be installed underground in the Canfranc laboratory (Spain) in a CROSS-dedicated facility. This experiment, comprising $\sim 3\times 10^{25}$ nuclei of $^{100}$Mo, will be a general test of the CROSS technology as well as a worldwide competitive search for neutrinoless double-beta decay, with sensitivity to the effective Majorana mass down to 70 meV in the most favorable conditions.

nucl-ex↗

The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects

CUPID-Mo is a bolometric experiment to search for neutrinoless double-beta decay ($0νββ$) of $^{100}$Mo. In this article, we detail the CUPID-Mo detector concept, assembly, installation in the underground laboratory in Modane in 2018, and provide results from the first datasets. The demonstrator consists of an array of 20 scintillating bolometers comprised of $^{100}$Mo-enriched 0.2 kg Li$_2$MoO$_4$ crystals. The detectors are complemented by 20 thin cryogenic Ge bolometers acting as light detectors to distinguish $α$ from $γ$/$β$ events by the detection of both heat and scintillation light signals. We observe good detector uniformity, facilitating the operation of a large detector array as well as excellent energy resolution of 5.3 keV (6.5 keV) FWHM at 2615 keV, in calibration (physics) data. Based on the observed energy resolutions and light yields a separation of $α$ particles at much better than 99.9\% with equally high acceptance for $γ$/$β$ events is expected for events in the region of interest for $^{100}$Mo $0νββ$. We present limits on the crystals' radiopurity ($\leq$3 $μ$Bq/kg of $^{226}$Ra and $\leq$2 $μ$Bq/kg of $^{232}$Th). Based on these initial results we also discuss a sensitivity study for the science reach of the CUPID-Mo experiment, in particular, the ability to set the most stringent half-life limit on the $^{100}$Mo $0νββ$ decay after half a year of livetime. The achieved results show that CUPID-Mo is a successful demonstrator of the technology - developed in the framework of the LUMINEU project - selected for the CUPID experiment, a proposed follow-up of CUORE, the currently running first tonne-scale cryogenic $0νββ$ experiment.

physics.ins-det↗

First test of a $\mathrm{CdMoO_4}$ scintillating bolometer for neutrinoless double beta decay experiments with $\mathrm{{}^{116}Cd}$ and $\mathrm{{}^{100}Mo}$ nuclides

A large cylindrical cadmium molybdate crystal with natural isotopic abundance has been used to fabricate a scintillating bolometer. The measurement was performed above ground at milli-Kelvin temperature, with simultaneous readout of the heat and the scintillation light. The energy resolution as FWHM has achieved from 5 keV (at 238 keV) to 13 keV (at 2615 keV). We present the results of the $α$ versus $β$/$γ$ events discrimination. The low internal trace contamination of the $\mathrm{CdMoO_4}$ crystal was evaluated as well. The detector performance with preliminary positive indications proves that cadmium molybdate crystal is a promising absorber for neutrinoless double beta decay scintillating bolometric experiments with $\mathrm{{}^{116}Cd}$ and $\mathrm{{}^{100}Mo}$ nuclides in the next-generation technique.

physics.ins-det↗

Sample-based calibration for cryogenic broadband microwave reflectometry measurements

The characteristic frequencies of a system provide important information on the phenomena that govern its physical properties. In this framework, there has recently been renewed interest in cryogenic microwave characterization for condensed matter systems since it allows to probe energy scales of the order of a few $μ$eV. However, broadband measurements of the absolute value of a sample response in this frequency range are extremely sensitive to its environment and require a careful calibration. In this paper, we present an \textit{in situ} calibration method for cryogenic broadband microwave reflectometry experiments that is both simple to implement and through which the effect of the sample electromagnetic environment can be minimized. The calibration references are here provided by the sample itself, at three reference temperatures where its impedance is assumed or measured, and not by external standards as is usual. We compare the frequency-dependent complex impedance (0.1--2 GHz) of an a-Nb$_{15}$Si$_{85}$ superconducting thin film obtained through this Sample-Based Calibration (SBC) and through an Open-Short-Load Standard Calibration (SC) when working at very low temperature (0.02--4 K) and show that the SBC allows us to obtain the absolute response of the sample. This method brings the calibration planes as close as possible to the sample, so that the environment electrodynamic response does not affect the measurement, provided it is temperature independent. This results in a heightened sensitivity, for a given experimental set--up.

cond-mat.supr-con↗

Charge-to-heat transducers exploiting the Neganov-Trofimov-Luke effect for light detection in rare-event searches

In this work we present how to fabricate large-area (15 cm2), ultra-low threshold germanium bolometric photo-detectors and how to operate them to detect few (optical) photons. These detectors work at temperatures as low as few tens of mK and exploit the Neganov-Trofimov-Luke (NTL) effect. They are operated as charge-to-heat transducers: the heat signal is linearly increased by simply changing a voltage bias applied to special metal electrodes, fabricated onto the germanium absorber, and read by a (NTD-Ge) thermal sensor. We fabricated a batch of five prototypes and ran them in different facilities with dilution refrigerators. We carefully studied how impinging spurious infrared radiation impacts the detector performances, by shining infrared photons via optical-fiber-guided LED signals, in a controlled manner, into the bolometers. We hence demonstrated how the radiation-tightness of the test environment tremendously enhances the detector performances, allowing to set electrode voltage bias up to 90 volts without any leakage current and signal-to-noise gain as large as a factor 12 (for visible photons). As consequence, for the first time we could operate large-area NTD-Ge-sensor-equipped NTL bolometric photo-detectors capable to reach sub 10-eV baseline noise (RMS). Such detectors open new frontiers for rare-event search experiments based on low light yield Ge-NTD equipped scintillating bolometers, such the CUPID neutrinoless double-beta decay experiment.

physics.ins-det↗

Searching for low-mass dark matter particles with a massive Ge bolometer operated above-ground

The EDELWEISS collaboration has performed a search for dark matter particles with masses below the GeV-scale with a 33.4-g germanium cryogenic detector operated in a surface lab. The energy deposits were measured using a neutron-transmutation-doped Ge thermal sensor with a 17.7~eV (RMS) baseline heat energy resolution leading to a 60~eV analysis energy threshold. Despite a moderate lead shielding and the high-background environment, the first sub-GeV spin-independent dark matter limit based on a germanium target has been achieved. The experiment provides the most stringent, nuclear recoil based, above-ground limit on spin-independent interactions above 600~MeV/c$^{2}$. The experiment also provides the most stringent limits on spin-dependent interactions with protons and neutrons below 1.3~GeV/c$^{2}$. Furthermore, the dark matter search results were studied in the context of Strongly Interacting Massive Particles, taking into account Earth-shielding effects, for which new regions of the available parameter space have been excluded. Finally, the dark matter search has also been extended to interactions via the Migdal effect, resulting for the first time in the exclusion of particles with masses between 45 and 150~MeV/c$^{2}$ with spin-independent cross sections ranging from $10^{-29}$ to $10^{-26}$~cm$^2$.

astro-ph.GA↗

Thermal architecture for the QUBIC cryogenic receiver

QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.

astro-ph.IM↗

Searches for electron interactions induced by new physics in the EDELWEISS-III germanium bolometers

We make use of the EDELWEISS-III array of germanium bolometers to search for electron interactions at the keV scale induced by phenomena beyond the Standard Model. A 90% C.L. lower limit is set on the electron lifetime decaying to invisibles, $τ> 1.2\times 10^{24}$ years. We investigate the emission of axions or axionlike particles (ALPs) by the Sun, constraining the coupling parameters $g_{ae}<1.1\times 10^{-11}$ and $g_{ae}\times g_{aN}^{\rm eff} < 3.5\times 10^{-17}$ at 90% C.L. in the massless limit. We also directly search for the absorption of bosonic dark matter particles that would constitute our local galactic halo. Limits are placed on the couplings of ALPs or hidden photon dark matter in the mass range $0.8 - 500$ keV/c$^2$. Prospects for searching for dark matter particles with masses down to 150 eV/c$^2$ using improved detectors are presented.

hep-ex↗

Complete event-by-event $α$/$γ(β)$ separation in a full-size TeO$_2$ CUORE bolometer by Neganov-Luke-magnified light detection

In the present work, we describe the results obtained with a large ($\approx 133$ cm$^3$) TeO$_2$ bolometer, with a view to a search for neutrinoless double-beta decay ($0νββ$) of $^{130}$Te. We demonstrate an efficient $α$ particle discrimination (99.9\%) with a high acceptance of the $0νββ$ signal (about 96\%), expected at $\approx 2.5$ MeV. This unprecedented result was possible thanks to the superior performance (10 eV rms baseline noise) of a Neganov-Luke-assisted germanium bolometer used to detect a tiny (70 eV) light signal from the TeO$_2$ detector, dominated by $γ$($β$)-induced Cherenkov radiation but exhibiting also a clear scintillation component. The obtained results represent a major breakthrough towards the TeO$_2$-based version of CUORE Upgrade with Particle IDentification (CUPID), a ton-scale cryogenic $0νββ$ experiment proposed as a follow-up to the CUORE project with particle identification. The CUORE experiment began recently a search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 125-cm$^3$ TeO$_2$ bolometers. The lack of $α$ discrimination in CUORE makes $α$ decays at the detector surface the dominant background component, at the level of $\approx 0.01$ counts/(keV kg y) in the region of interest. We show here, for the first time with a CUORE-size bolometer and using the same technology as CUORE for the readout of both heat and light signals, that surface $α$ background can be fully rejected.

physics.ins-det↗

Growth and characterization of a Li2Mg2(MoO4)3 scintillating bolometer

Lithium magnesium molybdate (Li$_2$Mg$_2$(MoO$_4$)$_3$) crystals were grown by the low-thermal-gradient Czochralski method. Luminescence properties of the material (emission spectra, thermally stimulated luminescence, dependence of intensity on temperature, phosphorescence) have been studied under X-Ray excitation in the temperature interval from 8 K to 400 K, while at the same being operated as a scintillating bolometer at 20 mK for the first time. We demonstrated that Li$_2$Mg$_2$(MoO$_4)_3$ crystals are a potentially promising detector material to search for neutrinoless double beta decay of $^{100}$Mo.

physics.ins-det↗

QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to look at the polarized Cosmic Microwave Background

In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called "self-calibration" is a technique deeply rooted in the interferometric nature of the instrument and allows us to clean the measured data from instrumental effects. The first module of QUBIC is a dual band instrument (150 GHz and 220 GHz) that will be deployed in Argentina during the Fall 2018.

astro-ph.IM↗

Development of $^{100}$Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search

This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2--0.4~kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the $Q$-value of the double-beta transition of $^{100}$Mo (3034~keV) is 4--6~keV FWHM. The rejection of the $α$-induced dominant background above 2.6~MeV is better than 8$σ$. Less than 10~$μ$Bq/kg activity of $^{232}$Th ($^{228}$Th) and $^{226}$Ra in the crystals is ensured by boule recrystallization. The potential of $^{100}$Mo-enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10~kg$\times$d exposure: the two neutrino double-beta decay half-life of $^{100}$Mo has been measured with the up-to-date highest accuracy as $T_{1/2}$ = [6.90 $\pm$ 0.15(stat.) $\pm$ 0.37(syst.)] $\times$ 10$^{18}$~yr. Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of $^{100}$Mo.

physics.ins-det↗