Searcharxiv⌕ Search

arXiv subjects

L. F. G. Gonzalez

Publications and source records attributed to L. F. G. Gonzalez.

At least 19 recordsLinked to original sources

From Safeguards Application to Fundamental Physics: Advancements in Reactor Neutrino Detection with the ν-Angra Experiment

Operating on a surface with high noise rates and requiring susceptible, yet small-scale detectors, the Neutrinos-Angra detector is an excellent platform for technological development and expertise in new detection methods. This report details the primary features of the detector, the electronics involved, and preliminary physics results from the operational phase, particularly the ON-OFF analysis comparing the signals with the reactor in operation (ON) and during the maintenance shut-down (OFF), demonstrating the detector's capability to monitor reactor activity. Additionally, we will briefly discuss the prospects of using a cryogenic calorimeter to detect neutrinos via Coherent Elastic Neutrino-Nucleus Scattering (CEvNS), highlighting potential advancements in neutrino detection technology. Looking ahead, the project promises to play a crucial role in the integration of Latin American scientists and engineers into global scientific collaborations, significantly contributing to the LASF4RI and the broader HECAP strategic framework.

hep-ex↗

Results from ON-OFF analysis of the Neutrinos-Angra detector

The Neutrinos Angra Experiment, a water-based Cherenkov detector, is located at the Angra dos Reis nuclear power plant in Brazil. Designed to detect electron antineutrinos produced in the nuclear reactor, the primary objective of the experiment is to demonstrate the feasibility of monitoring reactor activity using an antineutrino detector. This effort aligns with the International Atomic Energy Agency (IAEA) program to identify potential and novel technologies applicable to nonproliferation safeguards. Operating on the surface presents challenges such as high noise rates, necessitating the development of very sensitive, yet small-scale detectors. These conditions make the Angra experiment an excellent platform for both developing the application and gaining expertise in new technologies and analysis methods. The detector employs a water-based target doped with gadolinium to enhance its sensitivity to antineutrinos. In this work, we describe the main features of the detector and the electronics chain, including front-end and data acquisition components. We detail the data acquisition strategies and the methodologies applied for signal processing and event selection. Preliminary physics results suggest that the detector can reliably monitor reactor operations by detecting the inverse beta decay induced by electron antineutrinos from the reactor.

hep-ex↗

The Double Chooz antineutrino detectors

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.

physics.ins-det↗

Search for Signatures of Sterile Neutrinos with Double Chooz

We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e.\ comparing the data to the model prediction of disappearance in a data-to-data comparison of the two respective detectors. The analysis is optimized for a model of three active and one sterile neutrino. It is sensitive in the typical mass range $5 \cdot 10^{-3} $ eV$^2 \lesssim Δm^2_{41} \lesssim 3\cdot 10^{-1} $ eV$^2$ for mixing angles down to $\sin^2 2θ_{14} \gtrsim 0.02$. No significant disappearance additionally to the conventional disappearance related to $θ_{13} $ is observed and correspondingly exclusion bounds on the sterile mixing parameter $θ_{14} $ as function of $ Δm^2_{41} $ are obtained.

hep-ex↗

Reactor Rate Modulation oscillation analysis with two detectors in Double Chooz

A $θ_{13}$ oscillation analysis based on the observed antineutrino rates at the Double Chooz far and near detectors for different reactor power conditions is presented. This approach provides a so far unique simultaneous determination of $θ_{13}$ and the total background rates without relying on any assumptions on the specific background contributions. The analysis comprises 865 days of data collected in both detectors with at least one reactor in operation. The oscillation results are enhanced by the use of 24.06 days (12.74 days) of reactor-off data in the far (near) detector. The analysis considers the \nue interactions up to a visible energy of 8.5 MeV, using the events at higher energies to build a cosmogenic background model considering fast-neutrons interactions and $^{9}$Li decays. The background-model-independent determination of the mixing angle yields sin$^2(2θ_{13})=0.094\pm0.017$, being the best-fit total background rates fully consistent with the cosmogenic background model. A second oscillation analysis is also performed constraining the total background rates to the cosmogenic background estimates. While the central value is not significantly modified due to the consistency between the reactor-off data and the background estimates, the addition of the background model reduces the uncertainty on $θ_{13}$ to 0.015. Along with the oscillation results, the normalization of the anti-neutrino rate is measured with a precision of 0.86\%, reducing the 1.43\% uncertainty associated to the expectation.

hep-ex↗

Brazilian Report on Safeguards Application of Reactor Neutrinos

The Neutrinos Angra Experiment is a water-based Cherenkov detector located in the Angra dos Reis nuclear power plant. The experiment has completed a major step by finishing the commissioning of the detector and the data acquisition system at the experimental site. The experiment was designed to detect the electron antineutrinos produced by the nuclear reactor with the main purpose to demonstrate the feasibility of monitoring the reactor activity using an antineutrino detector. This effort is within the context of the International Atomic Energy Agency (IAEA) program to identify potential and novel technologies that can be applied for non-proliferation safeguards. Challenges, such as operating at the surface, therefore with huge noise rates, and the need to build very sensitive but small-scale detectors, make the Angra experiment an excellent platform for developing the application itself, as well as acquiring expertise in new technologies and analysis methods. In this report, we describe the main detector features and the electronics chain (front-end and data acquisition). We also report preliminary physics results obtained from the commissioning phase data. Finally, we address conclusions regarding the future perspectives to keep this program active, due to its importance in the insertion of Latin-American scientists and engineers in a world-scale cutting edge scientific program.

physics.ins-det↗

Neutrinos Angra experiment: commissioning and first operational measurements

The Neutrinos Angra Experiment has completed a major step by finishing the comissioning of the detector and the data acquisition system at the experimental site located in the Angra dos Reis nuclear power plant. The experiment consists of a water-based detector and associated electronics, both designed with the goal of detecting the electron antineutrinos produced by the nuclear reactor. The detection is possible due to the Inverse Beta Decay, where the final products in the water are photons in the UV-to-visible range of the spectrum. The assembled detector comprises three active volumes filled with water: (i) a cubic target detector for electron antineutrinos, covered by 32 8-inches PMTs, (ii) a lateral layer surrounding the target (veto) equipped with 4 PMTs and (iii) a third volume covering the top of both, also equipped with 4~PMTs. In the present document the main features of the detector assembly as well as the integration of the readout electronics on-site are reported. Finally, some operational characteristics are shown based on straightforward analysis of the first measurements performed during the last months with the fully working detector.

physics.ins-det↗

Yields and production rates of cosmogenic $^9$Li and $^8$He measured with the Double Chooz near and far detectors

The yields and production rates of the radioisotopes $^9$Li and $^8$He created by cosmic muon spallation on $^{12}$C, have been measured by the two detectors of the Double Chooz experiment. The identical detectors are located at separate sites and depths, which means they are subject to different muon spectra. The near (far) detector has an overburden of $\sim$120 m.w.e. ($\sim$300 m.w.e.) corresponding to a mean muon energy of $32.1\pm2.0\,\mathrm{GeV}$ ($63.7\pm5.5\,\mathrm{GeV}$). Comparing the data to a detailed simulation of the $^9$Li and $^8$He decays, the contribution of the $^8$He radioisotope at both detectors is found to be compatible with zero. The observed $^9$Li yields in the near and far detectors are $5.51\pm0.51$ and $7.90\pm0.51$, respectively, in units of $10^{-8}μ^{-1} \mathrm{g^{-1} cm^{2} }$. The shallow overburdens of the near and far detectors give a unique insight when combined with measurements by KamLAND and Borexino to give the first multi--experiment, data driven relationship between the $^9$Li yield and the mean muon energy according to the power law $Y = Y_0( / 1\,\mathrm{GeV})^{\overlineα}$, giving $\overlineα=0.72\pm0.06$ and $Y_0=(0.43\pm0.11)\times 10^{-8}μ^{-1} \mathrm{g^{-1} cm^{2}}$. This relationship gives future liquid scintillator based experiments the ability to predict their cosmogenic $^9$Li background rates.

hep-ex↗

Novel event classification based on spectral analysis of scintillation waveforms in Double Chooz

Liquid scintillators are a common choice for neutrino physics experiments, but their capabilities to perform background rejection by scintillation pulse shape discrimination is generally limited in large detectors. This paper describes a novel approach for a pulse shape based event classification developed in the context of the Double Chooz reactor antineutrino experiment. Unlike previous implementations, this method uses the Fourier power spectra of the scintillation pulse shapes to obtain event-wise information. A classification variable built from spectral information was able to achieve an unprecedented performance, despite the lack of optimization at the detector design level. Several examples of event classification are provided, ranging from differentiation between the detector volumes and an efficient rejection of instrumental light noise, to some sensitivity to the particle type, such as stopping muons, ortho-positronium formation, alpha particles as well as electrons and positrons. In combination with other techniques the method is expected to allow for a versatile and more efficient background rejection in the future, especially if detector optimization is taken into account at the design level.

physics.ins-det↗

Cosmic-muon characterization and annual modulation measurement with Double Chooz detectors

A study on cosmic muons has been performed for the two identical near and far neutrino detectors of the Double Chooz experiment, placed at $\sim$120 and $\sim$300 m.w.e. underground respectively, including the corresponding simulations using the MUSIC simulation package. This characterization has allowed to measure the muon flux reaching both detectors to be (3.64 $\pm$ 0.04) $\times$ 10$^{-4}$ cm$^{-2}$s$^{-1}$ for the near detector and (7.00 $\pm$ 0.05) $\times$ 10$^{-5}$ cm$^{-2}$s$^{-1}$ for the far one. The seasonal modulation of the signal has also been studied observing a positive correlation with the atmospheric temperature, leading to an effective temperature coefficient of $α_{T}$ = 0.212 $\pm$ 0.024 and 0.355 $\pm$ 0.019 for the near and far detectors respectively. These measurements, in good agreement with expectations based on theoretical models, represent one of the first measurements of this coefficient in shallow depth installations.

hep-ex↗

Characterization of the Spontaneous Light Emission of the PMTs used in the Double Chooz Experiment

During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical volume has been observed. A specific study of the ensemble of phenomena called "Light Noise" has been carried out in-situ, and in an external laboratory, in order to characterize the signals and to identify the possible processes underlying the effect. Some mechanisms of instrumental noise originating from the PMTs were identified and it has been found that the leading one arises from the light emission localized on the photomultiplier base and produced by the combined effect of heat and high voltage across the transparent epoxy resin covering the electric components. The correlation of the rate and the amplitude of the signal with the temperature has been observed. For the first detector in operation the induced background has been mitigated using online and offline analysis selections based on timing and light pattern of the signals, while a modification of the photomultiplier assembly has been implemented for the second detector in order to blacken the PMT bases.

physics.ins-det↗

Muon capture on light isotopes in Double Chooz

Using the Double Chooz detector, designed to measure the neutrino mixing angle $θ_{13}$, the products of $μ^-$ capture on $^{12}$C, $^{13}$C, $^{14}$N and $^{16}$O have been measured. Over a period of 489.5 days, $2.3\times10^6$ stopping cosmic $μ^-$ have been collected, of which $1.8\times10^5$ captured on carbon, nitrogen, or oxygen nuclei in the inner detector scintillator or acrylic vessels. The resulting isotopes were tagged using prompt neutron emission (when applicable), the subsequent beta decays, and, in some cases, $β$-delayed neutrons. The most precise measurement of the rate of $^{12}\mathrm C(μ^-,ν)^{12}\mathrm B$ to date is reported: $6.57^{+0.11}_{-0.21}\times10^{3}\,\mathrm s^{-1}$, or $(17.35^{+0.35}_{-0.59})\%$ of nuclear captures. By tagging excited states emitting gammas, the ground state transition rate to $^{12}$B has been determined to be $5.68^{+0.14}_{-0.23}\times10^3\,\mathrm s^{-1}$. The heretofore unobserved reactions $^{12}\mathrm C(μ^-,να)^{8}\mathrm{Li}$, $^{13}\mathrm C(μ^-,ν\mathrm nα)^{8}\mathrm{Li}$, and $^{13}\mathrm C(μ^-,ν\mathrm n)^{12}\mathrm B$ are measured. Further, a population of $β$n decays following stopping muons is identified with $5.5σ$ significance. Statistics limit our ability to identify these decays definitively. Assuming negligible production of $^{8}$He, the reaction $^{13}\mathrm C(μ^-,να)^{9}\mathrm{Li}$ is found to be present at the $2.7σ$ level. Limits are set on a variety of other processes.

nucl-ex↗

Measurement of $θ_{13}$ in Double Chooz using neutron captures on hydrogen with novel background rejection techniques

The Double Chooz collaboration presents a measurement of the neutrino mixing angle $θ_{13}$ using reactor $\overlineν_{e}$ observed via the inverse beta decay reaction in which the neutron is captured on hydrogen. This measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050m from two reactor cores. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties. Accidental coincidences, the dominant background in this analysis, are suppressed by more than an order of magnitude with respect to our previous publication by a multi-variate analysis. These improvements demonstrate the capability of precise measurement of reactor $\overlineν_{e}$ without gadolinium loading. Spectral distortions from the $\overlineν_{e}$ reactor flux predictions previously reported with the neutron capture on gadolinium events are confirmed in the independent data sample presented here. A value of $\sin^{2}2θ_{13} = 0.095^{+0.038}_{-0.039}$(stat+syst) is obtained from a fit to the observed event rate as a function of the reactor power, a method insensitive to the energy spectrum shape. A simultaneous fit of the hydrogen capture events and of the gadolinium capture events yields a measurement of $\sin^{2}2θ_{13} = 0.088\pm0.033$(stat+syst).

hep-ex↗

Improved measurements of the neutrino mixing angle $θ_{13}$ with the Double Chooz detector

The Double Chooz experiment presents improved measurements of the neutrino mixing angle $θ_{13}$ using the data collected in 467.90 live days from a detector positioned at an average distance of 1050 m from two reactor cores at the Chooz nuclear power plant. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties with respect to previous publications, whereas the efficiency of the $\barν_{e}$ signal has increased. The value of $θ_{13}$ is measured to be $\sin^{2}2θ_{13} = 0.090 ^{+0.032}_{-0.029}$ from a fit to the observed energy spectrum. Deviations from the reactor $\barν_{e}$ prediction observed above a prompt signal energy of 4 MeV and possible explanations are also reported. A consistent value of $θ_{13}$ is obtained from a fit to the observed rate as a function of the reactor power independently of the spectrum shape and background estimation, demonstrating the robustness of the $θ_{13}$ measurement despite the observed distortion.

hep-ex↗

Ortho-positronium observation in the Double Chooz Experiment

The Double Chooz experiment measures the neutrino mixing angle $θ_{13}$ by detecting reactor $\barν_e$ via inverse beta decay. The positron-neutron space and time coincidence allows for a sizable background rejection, nonetheless liquid scintillator detectors would profit from a positron/electron discrimination, if feasible in large detector, to suppress the remaining background. Standard particle identification, based on particle dependent time profile of photon emission in liquid scintillator, can not be used given the identical mass of the two particles. However, the positron annihilation is sometimes delayed by the ortho-positronium (o-Ps) metastable state formation, which induces a pulse shape distortion that could be used for positron identification. In this paper we report on the first observation of positronium formation in a large liquid scintillator detector based on pulse shape analysis of single events. The o-Ps formation fraction and its lifetime were measured, finding the values of 44$\%$ $\pm$ 12$\%$ (sys.) $\pm$ 5$\%$ (stat.) and $3.68$ns $\pm$ 0.17ns (sys.) $\pm$ 0.15ns (stat.) respectively, in agreement with the results obtained with a dedicated positron annihilation lifetime spectroscopy setup.

physics.ins-det↗

Precision Muon Reconstruction in Double Chooz

We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volumes. All muons are fit under the hypothesis that they are through-going and ultrarelativistic. If the energy depositions suggest that the muon may have stopped, the reconstruction fits also for this hypothesis and chooses between the two via the relative goodness-of-fit. In the ideal case of a through-going muon intersecting the center of the detector, the resolution is ~40 mm in each transverse dimension. High quality muon reconstruction is an important tool for reducing the impact of the cosmogenic isotope background in Double Chooz.

physics.ins-det↗

Background-independent measurement of $θ_{13}$ in Double Chooz

The oscillation results published by the Double Chooz collaboration in 2011 and 2012 rely on background models substantiated by reactor-on data. In this analysis, we present a background-model-independent measurement of the mixing angle $θ_{13}$ by including 7.53 days of reactor-off data. A global fit of the observed neutrino rates for different reactor power conditions is performed, yielding a measurement of both $θ_{13}$ and the total background rate. The results on the mixing angle are improved significantly by including the reactor-off data in the fit, as it provides a direct measurement of the total background rate. This reactor rate modulation analysis considers antineutrino candidates with neutron captures on both Gd and H, whose combination yields $\sin^2(2θ_{13})=$ 0.102 $\pm$ 0.028(stat.) $\pm$ 0.033(syst.). The results presented in this study are fully consistent with the ones already published by Double Chooz, achieving a competitive precision. They provide, for the first time, a determination of $θ_{13}$ that does not depend on a background model.

hep-ex↗

First Measurement of θ_13 from Delayed Neutron Capture on Hydrogen in the Double Chooz Experiment

The Double Chooz experiment has determined the value of the neutrino oscillation parameter $θ_{13}$ from an analysis of inverse beta decay interactions with neutron capture on hydrogen. This analysis uses a three times larger fiducial volume than the standard Double Chooz assessment, which is restricted to a region doped with gadolinium (Gd), yielding an exposure of 113.1 GW-ton-years. The data sample used in this analysis is distinct from that of the Gd analysis, and the systematic uncertainties are also largely independent, with some exceptions, such as the reactor neutrino flux prediction. A combined rate- and energy-dependent fit finds $\sin^2 2θ_{13}=0.097\pm 0.034(stat.) \pm 0.034 (syst.)$, excluding the no-oscillation hypothesis at 2.0 σ. This result is consistent with previous measurements of $\sin^2 2θ_{13}$.

hep-ex↗