SearcharxivSearch

arXiv subjects

L. H. Wu

Publications and source records attributed to L. H. Wu.

2 recordsLinked to original sources

Track-based alignment for the BESIII CGEM detector in the cosmic-ray test

The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector operating on the Beijing Electron Positron Collider II (BEPCII). After more than ten year's operation, the efficiency of the inner layers of the Main Drift Chamber (MDC) decreased significantly. To solve this issue, the BESIII collaboration is planning to replace the inner part of the MDC with three layers of Cylindrical triple Gas Electron Multipliers (CGEM). The transverse plane spatial resolution of CGEM is required to be 120 $μ$m or better. To meet this goal, a careful calibration of the detector is necessary to fully exploit the potential of the CGEM detector. In all the calibrations, the detector alignment plays an important role to improve the detector precision. The track-based alignment for the CGEM detector with the Millepede algorithm is implemented to reduce the uncertainties of the hit position measurement. Using the cosmic-ray data taken in 2020 with the two layers setup, the displacement and rotation of the outer layer with respect to the inner layer is determined by a simultaneous fit applied to more than 160000 tracks. A good alignment precision has been achieved that guarantees the design request could be satisfied in the future. A further alignment is going to be performed using the combined information of tracks from cosmic-ray and collisions after the CGEM is installed into the BESIII detector.

hep-ex

Aging effect in the BESIII drift chamber

As the main tracking detector of BESIII, the drift chamber works for accurate measurements of the tracking and the momentum of the charged particles decayed from the reaction of BEPCII e+ and e-. After operation six years, the drift chamber is suffering from aging problems due to huge beam related background. The gains of the cells in the first ten layers experience an obvious decrease, reaching a maximum of about 29% for the first layer cells. Two calculation methods for the gains change (Bhabha events and accumulated charges with 0.3% aging ratio for inner chamber cells) get almost the same results. For the Malter effect encountered by the inner drift chamber in Jan., 2012, about 0.2% water vapor was added to MDC gas mixture to solve this cathode aging problem. These results provide an important reference for MDC operation high voltage setting and the upgrade of the inner drift chamber.

physics.ins-det