SearcharxivSearch

arXiv subjects

L. Hawkins

Publications and source records attributed to L. Hawkins.

7 recordsLinked to original sources

AION-10: Technical Design Report for a 10m Atom Interferometer in Oxford

This Technical Design Report presents AION-10, a 10-meter atom interferometer to be located at Oxford University using ultracold strontium atoms to make precision measurements of fundamental physics. AION-10 serves as both a prototype for future larger-scale experiments and a versatile scientific instrument capable of conducting its own diverse physics programme. The design features a 10-meter vertical tower housing two atom interferometer sources in an ultra-high vacuum environment. Key engineering challenges include achieving nanometer-level vibrational stability and precise magnetic field control. Solutions include active vibration isolation, specialized magnetic shielding, and a modular assembly approach using professional lifting equipment. Detailed analysis confirms the design meets all performance requirements, with critical optical components remaining within our specifications 97% of the time under realistic operating conditions. Vacuum and vibration measurements in the host building validate that the instrument will achieve the precision needed for quantum sensing applications. This work establishes the technical foundation for scaling atom interferometry to longer baselines while creating a cutting-edge facility for precision measurements that could advance our understanding of fundamental physics.

physics.atom-ph

A prototype differential atom interferometer for fundamental physics

Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for Very Long-Baseline Atom Interferometers (VLBAIs) such as AION, MAGIS, AICE and AEDGE that aim to detect frequencies at which ground-based and space-borne laser interferometers lose sensitivity. VLBAIs look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. Experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87Sr, realising for the first time a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the Standard Quantum Limit with no excess noise beyond atom shot noise, and the differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, emulating the conditions expected in a VLBAI. We further demonstrate recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomised conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying VLBAIs and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter.

hep-ex

Centralised Design and Production of the Ultra-High Vacuum and Laser-Stabilisation Systems for the AION Ultra-Cold Strontium Laboratories

This paper outlines the centralised design and production of the Ultra-High-Vacuum sidearm and Laser-Stabilisation systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilisation, and on the loading rate for the 3D Magneto-Optical Trap are presented. Streamlining the design and production of the sidearm and laser stabilisation systems enabled the AION Collaboration to build and equip in parallel five state-of-the-art Ultra-Cold Strontium Laboratories within 24 months by leveraging key expertise in the collaboration. This approach could serve as a model for the development and construction of other cold atom experiments, such as atomic clock experiments and neutral atom quantum computing systems, by establishing dedicated design and production units at national laboratories.

physics.atom-ph

Commissioning the HI Observing Mode of the Beamformer for the Cryogenically Cooled Focal L-band Array for the GBT (FLAG)

We present the results of commissioning observations for a new digital beamforming back end for the Focal plane L-band Array for the Robert C. Byrd Green Bank Telescope (FLAG), a cryogenically cooled Phased Array Feed (PAF) with the lowest measured T_sys/eta of any PAF outfitted on a radio telescope to date. We describe the custom software used to apply beamforming weights to the raw element covariances to create research quality spectral line images for the new fine-channel mode, study the stability of the beam weights over time, characterize FLAG's sensitivity over a frequency range of 150 MHz, and compare the measured noise properties and observed distribution of neutral hydrogen emission from several extragalactic and Galactic sources with data obtained with the current single-pixel L-band receiver. These commissioning runs establish FLAG as the preeminent PAF receiver currently available for spectral line observations on the world's major radio telescopes.

astro-ph.IM

Performance of a highly sensitive, 19-element, dual-polarization, cryogenic L-band Phased Array Feed on the Green Bank Telescope

A new 1.4 GHz 19-element, dual-polarization, cryogenic phased array feed (PAF) radio astronomy receiver has been developed for the Robert C. Byrd Green Bank Telescope (GBT) as part of FLAG (Focal L-band Array for the GBT) project. Commissioning observations of calibrator radio sources show that this receiver has the lowest reported beamformed system temperature ($T_{\rm sys}$) normalized by aperture efficiency ($η$) of any phased array receiver to date. The measured $T_{\rm sys}/η$ is $25.4 \pm 2.5$ K near 1350 MHz for the boresight beam, which is comparable to the performance of the current 1.4 GHz cryogenic single feed receiver on the GBT. The degradation in $T_{\rm sys}/η$ at $\sim$ 4 arcmin (required for Nyquist sampling) and $\sim$ 8 arcmin offsets from the boresight is, respectively, $\sim$ 1\% and $\sim$ 20\% of the boresight value. The survey speed of the PAF with seven formed beams is larger by a factor between 2.1 and 7 compared to a single beam system depending on the observing application. The measured performance, both in frequency and offset from boresight, qualitatively agree with predictions from a rigorous electromagnetic model of the PAF. The astronomical utility of the receiver is demonstrated by observations of the pulsar B0329+54 and an extended HII region, the Rosette Nebula. The enhanced survey speed with the new PAF receiver will enable the GBT to carry out exciting new science, such as more efficient observations of diffuse, extended neutral hydrogen emission from galactic in-flows and searches for Fast Radio Bursts.

astro-ph.IM

A Highly-Sensitive Cryogenic Phased Array Feed for the Green Bank Telescope

In this paper, we describe the development of a new L-band (1.4 GHz) Cryogenic Phased Array Feed (PAF) system, referred to as the GBT2 array. Results from initial measurements made with the GBT2 array are also presented. The PAF was developed for the Green Bank Telescope (GBT) as part of the Focal L-band Array for the GBT (FLAG) project. During the first stage of the development work (Phase I), a prototype cryogenic 19 element dual-polarized array with "Kite" dipole elements was developed and tested on the GBT. The measured system temperature over efficiency ($T_{sys}/η$) ratio for the bore sight beam of the Kite array was 45.5 K at 1.55 GHz. The off-boresight $T_{sys}/η$ shows an increase by 13 K at an offset equal to the half power beam width (7$^{'}$.2 at 1.7 GHz). Our measurements indicate that the off-boresight degradation and field-of-view (FoV) limitation of the Kite array is simply due to the fixed array size. To increase the FoV, a new 19-element GBT2 array with larger array spacing was developed during FLAG Phase II. The frequency response of the array was optimized from 1.2 to 1.6 GHz. A system with larger cryostat, new low noise amplifiers (LNAs), down-conversion and digitization close to the front end, unformatted digital transmission over fiber, ROACH II based polyphase filter banks (PFBs) with bandwidth 150 MHz and a data acquisition system that records voltage samples from one of the PFB channels were all developed. The data presented here is processed off-line. The receiver temperature measured with the new system is 17 K at 1.4 GHz, an improvement $>$ 8 K over the previous Kite array. Measurements with the GBT2 array on the telescope are in progress. A real time 150 MHz beamformer is also being developed as part of an NSF-funded collaboration between NRAO/GBO/BYU \& West Virginia University (Beamformer Project) to support science observations.

astro-ph.IM

Commissioning of FLAG: A phased array feed for the GBT

Phased Array Feed (PAF) technology is the next major advancement in radio astronomy in terms of combining high sensitivity and large field of view. The Focal L-band Array for the Green Bank Telescope (FLAG) is one of the most sensitive PAFs developed so far. It consists of 19 dual-polarization elements mounted on a prime focus dewar resulting in seven beams on the sky. Its unprecedented system temperature of$\sim$17 K will lead to a 3 fold increase in pulsar survey speeds as compared to contemporary single pixel feeds. Early science observations were conducted in a recently concluded commissioning phase of the FLAG where we clearly demonstrated its science capabilities. We observed a selection of normal and millisecond pulsars and detected giant pulses from PSR B1937+21.

astro-ph.IM