Searcharxiv⌕ Search

arXiv subjects

L. Hayen

Publications and source records attributed to L. Hayen.

26 records · Page 2Linked to original sources

$\mathcal{F}t$ values of the mirror $β$ transitions and the weak magnetism induced current in allowed nuclear $β$ decay

In recent years a number of correlation measurements in nuclear $β$ decay have been performed reaching a precision of the order of 1\% and below and it is expected that even higher precision will be reached in the near future. At these levels of precision higher-order corrections due to e.g. recoil terms induced by the strong interaction and radiative corrections cannot necessarily be neglected anymore when interpreting these results in terms of new physics or extracting a value for the $V_{ud}$ quark-mixing matrix element. We provide here an update of the $\mathcal{F} t$ values of the $T=1/2$ mirror $β$ decays as well as an overview of current experimental and theoretical knowledge of the most important recoil term, weak magnetism, for both the $T=1/2$ mirror $β$ transitions and a large set of $β$ decays in higher isospin multiplets. The matrix elements determining weak magnetism were calculated in the nuclear shell model and cross-checked against experimental data, showing overall good agreement. Additionally, we show that further insight can be obtained from properly deformed nuclear potentials, in particular for mirror $T=1/2$ decays.. The results provide new insights in the size of weak magnetism, extending the available information to $β$ transitions of nuclei with masses up to $A =$ 75. This provides important guidance for the planning and interpretation of ongoing and new precise correlation measurements in nuclear $β$ decay searching for new physics or to extract the $V_{ud}$ quark-mixing matrix element in mirror $β$ decays. This more detailed knowledge of weak magnetism can also be of interest for further theoretical work related to the reactor neutrino problem.

nucl-ex↗

Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment

An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser drives all magnetometers that are located in a high-vacuum chamber, with a selection of the sensors mounted on a high-voltage electrode. We describe details of the Cs sensors' construction and modes of operation, emphasizing the accuracy and sensitivity of the magnetic field readout. We present two applications of the magnetometer array directly beneficial to the nEDM experiment: (i) the implementation of a strategy to correct for the drift of the vertical magnetic field gradient and (ii) a procedure to homogenize the magnetic field. The first reduces the uncertainty of the new nEDM result. The second enables transverse neutron spin relaxation times exceeding 1500 s, improving the statistical sensitivity of the nEDM experiment by about 35% and effectively increasing the rate of nEDM data taking by a factor of 1.8.

physics.atom-ph↗

Measurement of the permanent electric dipole moment of the neutron

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.

hep-ex↗

Using Nab to determine correlations in unpolarized neutron decay

The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and reconstruct the correlation between the antineutrino and electron momenta. Excellent understanding of systematic effects affecting timing and energy reconstruction using this detection system are required. To explore these effects, a series of ex situ studies have been undertaken, including a search for a Fierz term at a less sensitive level of $Δb_F<10^{-2}$ in the beta decay of $^{45}$Ca using the UCNA spectrometer.

nucl-ex↗

First-forbidden transitions in the reactor anomaly

We study the dominant forbidden transitions in the antineutrino spectra of the fission actinides from 4 MeV onward using the nuclear shell model. Through explicit calculation of the shape factor, taking into account Coulomb corrections, we show the expected changes on cumulative electron and antineutrino spectra. Compared to the usual allowed approximation this results in a minor decrease of electron spectra from 4 MeV and onward, whereas an increase of several percent is observed in antineutrino spectra. We show that, despite their limited number, forbidden transitions dominate the spectral flux for most of the experimentally accessible range. Based on the shell model calculations we attempt a parametrization of forbidden transitions and propose a spectral correction for all forbidden transitions. We enforce correspondence with the ILL dataset using a summation+conversion approach. When compared against modern reactor neutrino experiments, the resultant spectral change is observed to be of comparable magnitude and shape as the reported spectral shoulder, drastically decreasing the statistical significance of the latter.

nucl-th↗

Multi-Wire 3D Gas Tracker for Searching New Physics in Nuclear Beta Decay

Searches of new physics beyond the Standard Model (SM) performed at low energy frontiers are complementary to experiments carried out at high energy colliders. Among the methods for testing the SM and beyond at low energies are the precision spectrum shape and correlation coefficient measurements in nuclear and neutron beta decay. In order to study tiny effects in beta spectrum shape, a special spectrometer was built. It consists of a 3D low pressure gas tracker (drift chamber with hexagonal cells, signal readout at both wire ends) and plastic scintillators for triggering data acquisition and registration of the beta particle energy. The results of the characterization process indicate the possibility of using such a gas tracker in a range of experiments with low energy electrons where beta particle tracking with minimal kinematics deterioration is beneficial. Application of this technique is also planned for neutron decay correlation experiments. In the paper, the first application of this tracker in a high-precision beta spectrum shape study is discussed. The measurement technique, commissioning results, and the future outlook are presented.

physics.ins-det↗

A device for simultaneous spin analysis of ultracold neutrons

We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons. The gain in statistical sensitivity obtained with the simultaneous spin analyser is $(18.2\pm6.1)\%$ relative to the former sequential analyser under nominal running conditions.

physics.ins-det↗

A highly stable atomic vector magnetometer based on free spin precession

We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 $μ$T magnetic field. Multiple circularly polarized laser beams were used to probe the free spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scalar resolution of less than 80 fT was reached with integration times of 1.6 to 6 s. We were able to measure the magnetic field direction with a resolution better than 10 $μ$rad for integration times from 10 s up to 2000 s.

physics.atom-ph↗