SearcharxivSearch

arXiv subjects

L. Iddir

Publications and source records attributed to L. Iddir.

9 recordsLinked to original sources

Constraints on Sub-MeV Dark Matter from Solar Reflection with DAMIC-M

The Sun acts as a natural dark matter accelerator. Galactic halo particles scattering in the solar plasma emerge with velocities well beyond the Galactic escape speed, providing a boosted flux that extends the kinematic reach of direct detection experiments into the sub-MeV mass regime. We present constraints on solar-reflected dark matter (SRDM) from the DAMIC-M prototype detector using $\sim$1.3~kg-day of data acquired with silicon skipper charge coupled devices (CCDs) at the Modane Underground Laboratory. Exploiting the spatial diffusion signature of low-energy electron recoils, we derive 90% C.L. upper limits on the DM-electron scattering cross section for both heavy- and ultralight-mediator benchmarks, reaching $\bar{\sigma}_e\sim 3.16 \cdot 10^{-37} \rm{cm^2}$ at $0.1$ MeV. For the ultralight mediator, our limits are competitive with the world-leading constraints, achieved with an integrated exposure of $\sim1.3$~kg-day. These results probe the parameter space between stellar-cooling bounds and terrestrial limits from standard halo searches, a region inaccessible to direct detection experiments relying solely on the standard halo flux.

hep-ex

Daily Modulation Constraints on Light Dark Matter with DAMIC-M

The flux of Hidden Sector particles from the Galactic halo reaching an underground detector can be significantly attenuated by interactions within the Earth for sufficiently large scattering crosssections. This attenuation gives rise to a characteristic daily modulation in the detection rate, due to Earth's rotation. We present results from a search for such a modulation using a 1.257 kg-day dataset collected with the DAMIC-M Low Background Chamber. A model-independent analysis reveals no significant modulation in the 1e- event rate over periods from 1 to 48 h, highlighting the excellent temporal stability of the detector. In a complementary model-dependent analysis, we target the expected daily modulation signature of Hidden Sector particles, with masses in the range [0.53,2] MeV/c2, interacting with electrons via a dark photon mediator. By leveraging the expected temporal evolution of the signal, we set improved constraints on Dark Matter masses below 1.2 MeV/c2, surpassing our previous limits.

hep-ex

First Production of Skipper-CCD Modules for the DAMIC-M Experiment

The DAMIC-M experiment will search for sub-GeV dark matter particles with a large array of silicon skipper charge-coupled devices (CCDs) at the Modane Underground Laboratory (LSM) in France. After five years of development, we recently completed the production of 28 CCD modules at the University of Washington, each consisting of four 9-megapixel skipper CCDs. Material screening and background controls were implemented to meet stringent radio-purity targets, while extensive testing was employed to select science-grade CCDs for the modules and confirm their excellent performance after fabrication. Further testing at LSM will select 26 of these modules (${\sim}$350 g active mass) to be installed and operated in the DAMIC-M detector in early 2026.

physics.ins-det

Probing Benchmark Models of Hidden-Sector Dark Matter with DAMIC-M

We report on a search for sub-GeV dark matter (DM) particles interacting with electrons using the DAMIC-M prototype detector at the Modane Underground Laboratory. The data feature a significantly lower detector single $e^-$ rate (factor 50) compared to our previous search, while also accumulating a ten times larger exposure of $\sim$1.3 kg-day. DM interactions in the skipper charge-coupled devices (CCDs) are searched for as patterns of two or three consecutive pixels with a total charge between 2 and 4 $e^-$. We find 144 candidates of 2 $e^-$ and 1 candidate of 4 $e^-$, where 141.5 and 0.071, respectively, are expected from background. With no evidence of a DM signal, we place stringent constraints on DM particles with masses between 1 and 1000 MeV/$c^2$ interacting with electrons through an ultra-light or heavy mediator. For large ranges of DM masses below 1 GeV/c$^2$, we exclude theoretically-motivated benchmark scenarios where hidden-sector particles are produced as a major component of DM in the Universe through the freeze-in or freeze-out mechanisms.

hep-ex

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment is designed to search for light dark matter (m$_{\chi}$<10\,GeV/c$^2$) at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-M will use skipper charge-coupled devices (CCDs) as a kg-scale active detector target. Its single-electron resolution will enable eV-scale energy thresholds and thus world-leading sensitivity to a range of hidden sector dark matter candidates. A DAMIC-M prototype, the Low Background Chamber (LBC), has been taking data at LSM since 2022. The LBC provides a low-background environment, which has been used to characterize skipper CCDs, study dark current, and measure radiopurity of materials planned for DAMIC-M. It also allows testing of various subsystems like readout electronics, data acquisition software, and slow control. This paper describes the technical design and performance of the LBC.

physics.ins-det

Nuclear Recoil Identification in a Scientific Charge-Coupled Device

Charge-coupled devices (CCDs) are a leading technology in direct dark matter searches because of their eV-scale energy threshold and high spatial resolution. The sensitivity of future CCD experiments could be enhanced by distinguishing nuclear recoil signals from electronic recoil backgrounds in the CCD silicon target. We present a technique for event-by-event identification of nuclear recoils based on the spatial correlation between the primary ionization event and the lattice defect left behind by the recoiling atom, later identified as a localized excess of leakage current under thermal stimulation. By irradiating a CCD with an $^{241}$Am$^{9}$Be neutron source, we demonstrate $>93\%$ identification efficiency for nuclear recoils with energies $>150$ keV, where the ionization events were confirmed to be nuclear recoils from topology. The technique remains fully efficient down to 90 keV, decreasing to 50$\%$ at 8 keV, and reaching ($6\pm2$)$\%$ at 1.5--3.5 keV. Irradiation with a $^{24}$Na $\gamma$-ray source shows no evidence of defect generation by electronic recoils, with the fraction of electronic recoils with energies $<85$ keV that are spatially correlated with defects $<0.1$$\%$.

physics.ins-det

Search for Daily Modulation of MeV Dark Matter Signals with DAMIC-M

Dark Matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from DM with MeV-scale mass. A model-independent analysis finds no modulation in the rate of 1$e^-$ events with sidereal period, where a DM signal would appear. We then use these data to place exclusion limits on DM in the mass range [0.53, 2.7] MeV/c$^2$ interacting with electrons via a dark photon mediator. Taking advantage of the time-dependent signal we improve by $\sim$2 orders of magnitude on our previous limit obtained from the total rate of 1$e^-$ events, using the same data set. This daily modulation search represents the current strongest limit on DM-electron scattering via ultralight mediators for DM masses around 1 MeV/c$^2$.

hep-ex

Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs

We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ${\sim}7$ events per kg-day and electron-equivalent energies of ${\sim}80~$eV, whose origin remains unknown.

astro-ph.CO

First Constraints from DAMIC-M on Sub-GeV Dark-Matter Particles Interacting with Electrons

We report constraints on sub-GeV dark matter particles interacting with electrons from the first underground operation of DAMIC-M detectors. The search is performed with an integrated exposure of 85.23 g days, and exploits the subelectron charge resolution and low level of dark current of DAMIC-M charge-coupled devices (CCDs). Dark-matter-induced ionization signals above the detector dark current are searched for in CCD pixels with charge up to 7e$^-$. With this dataset we place limits on dark matter particles of mass between 0.53 and 1000 MeV/$c^2$, excluding unexplored regions of parameter space in the mass ranges [1.6,1000] MeV/$c^2$ and [1.5,15.1] MeV/$c^2$ for ultralight and heavy mediator interactions, respectively.

hep-ex