SearcharxivSearch

arXiv subjects

L. Julien

Publications and source records attributed to L. Julien.

6 recordsLinked to original sources

The next generation of laser spectroscopy experiments using light muonic atoms

Precision spectroscopy of light muonic atoms provides unique information about the atomic and nuclear structure of these systems and thus represents a way to access fundamental interactions, properties and constants. One application comprises the determination of absolute nuclear charge radii with unprecedented accuracy from measurements of the 2S$\,$-$\,$2P Lamb shift. Here, we review recent results of nuclear charge radii extracted from muonic hydrogen and helium spectroscopy and present experiment proposals to access light muonic atoms with $Z \geq 3$. In addition, our approaches towards a precise measurement of the Zemach radii in muonic hydrogen ($μ$p) and helium ($μ$$^{3}$He$^{+}$) are discussed. These results will provide new tests of bound-state quantum-electrodynamics in hydrogen-like systems and can be used as benchmarks for nuclear structure theories.

physics.atom-ph

The proton radius puzzle

High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muonic deuterium.

physics.atom-ph

Experiments towards resolving the proton charge radius puzzle

We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from scattering and regular hydrogen spectroscopy.

physics.atom-ph

Muonic hydrogen cascade time and lifetime of the short-lived $2S$ state

Metastable ${2S}$ muonic-hydrogen atoms undergo collisional ${2S}$-quenching, with rates which depend strongly on whether the $μp$ kinetic energy is above or below the ${2S}\to {2P}$ energy threshold. Above threshold, collisional ${2S} \to {2P}$ excitation followed by fast radiative ${2P} \to {1S}$ deexcitation is allowed. The corresponding short-lived $μp ({2S})$ component was measured at 0.6 hPa $\mathrm{H}_2$ room temperature gas pressure, with lifetime $τ_{2S}^\mathrm{short} = 165 ^{+38}_{-29}$ ns (i.e., $λ_{2S}^\mathrm{quench} = 7.9 ^{+1.8}_{-1.6} \times 10^{12} \mathrm{s}^{-1}$ at liquid-hydrogen density) and population $ε_{2S}^\mathrm{short} = 1.70^{+0.80}_{-0.56}$ % (per $μp$ atom). In addition, a value of the $μp$ cascade time, $T_\mathrm{cas}^{μp} = (37\pm5)$ ns, was found.

physics.atom-ph

Proposal for new experimental schemes to realize the Avogadro constant

We propose two experimental schemes to determine and so to realize the Avogadro constant $N\_{A}$ at the level of 10$^{-7}$ or better with a watt balance experiment and a cold atom experiment measuring $h/m(X)$ (where $h$ is the Planck constant and $m(X)$ the mass of the atom $X$). We give some prospects about achievable uncertainties and we discuss the opportunity to test the existence of possible unknown correction factors for the Josephson effect and quantum Hall effect.

physics.atom-ph

Planar LAAPDs: Temperature Dependence, Performance, and Application in Low Energy X-ray Spectroscopy

An experiment measuring the 2S Lamb shift in muonic hydrogen mup is being performed at the Paul Scherrer Institute, Switzerland. It requires small and compact detectors for 1.9 keV x rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We have chosen Large Area Avalanche Photodiodes (LAAPDs) from Radiation Monitoring Devices as x-ray detectors, and they were used during the last data taking period in 2003. For x-ray spectroscopy applications, these LAAPDs have to be cooled in order to suppress the dark current noise, hence, a series of tests were performed to choose the optimal operation temperature. Specifically, the temperature dependence of gain, energy resolution, dark current, excess noise factor, and detector response linearity was studied. Finally, details of the LAAPDs application in the muonic hydrogen experiment as well as their response to alpha particles are presented.

physics.ins-det