Searcharxiv⌕ Search

arXiv subjects

L. L. Tsai

Publications and source records attributed to L. L. Tsai.

3 recordsLinked to original sources

Posture-Dependent Human 3He Lung Imaging in an Open Access MRI System: Initial Results

The human lung and its functions are extremely sensitive to orientation and posture, and debate continues as to the role of gravity and the surrounding anatomy in determining lung function and heterogeneity of perfusion and ventilation. However, study of these effects is difficult. The conventional high-field magnets used for most hyperpolarized 3He MRI of the human lung, and most other common radiological imaging modalities including PET and CT, restrict subjects to lying horizontally, minimizing most gravitational effects. In this paper, we briefly review the motivation for posture-dependent studies of human lung function, and present initial imaging results of human lungs in the supine and vertical body orientations using inhaled hyperpolarized 3He gas and an open-access MRI instrument. The open geometry of this MRI system features a "walk-in" capability that permits subjects to be imaged in vertical and horizontal positions, and potentially allows for complete rotation of the orientation of the imaging subject in a two-dimensional plane. Initial results include two-dimensional lung images acquired with ~ 4 mm in-plane resolution and three-dimensional images with ~ 1.5 cm slice thickness. Effects of posture variation are observed.

physics.med-ph↗

Interstitial gas and density-segregation in vertically-vibrated granular media

We report experimental studies of the effect of interstitial gas on mass-density-segregation in a vertically-vibrated mixture of equal-sized bronze and glass spheres. Sufficiently strong vibration in the presence of interstitial gas induces vertical segregation into sharply separated bronze and glass layers. We find that the segregated steady state (i.e., bronze or glass layer on top) is a sensitive function of gas pressure and viscosity, as well as vibration frequency and amplitude. In particular, we identify distinct regimes of behavior that characterize the change from bronze-on-top to glass-on-top steady-state.

cond-mat.soft↗

3He Lung Imaging in an Open Access, Very-Low-Field Human MRI System

The human lung and its functions are extremely sensitive to gravity, however the conventional high-field magnets used for most laser-polarized 3He MRI of the human lung restrict subjects to lying horizontally. Imaging of human lungs using inhaled laser-polarized 3He gas is demonstrated in an open-access very-low-magnetic-field (< 5 mT) MRI instrument. This prototype device employs a simple, low-cost electromagnet, with an open geometry that allows variation of the orientation of the imaging subject in a two-dimensional plane. As a demonstration, two-dimensional lung images were acquired with 4 mm in-plane resolution from a subject in two orientations: lying supine, and sitting in a vertical position with one arm raised. Experience with this prototype device will guide optimization of a second-generation very-low-field imager to enable studies of human pulmonary physiology as a function of subject orientation.

physics.med-ph↗