Searcharxiv⌕ Search

arXiv subjects

L. Li

Publications and source records attributed to L. Li.

At least 73 records · Page 4Linked to original sources

Observation of the toroidal rotation in a new designed compact torus system for EAST

Compact torus injection is considered as a high promising approach to realize central fueling in the future tokamak device. Recently, a compact torus injection system has been developed for the Experimental Advanced Superconducting Tokamak, and the preliminary results have been carried out. In the typical discharges of the early stage, the velocity, electron density and particles number of the CT can reach 56.0 km/s, 8.73*10^20 m^(-3) and 2.4*10^18 (for helium), respectively. A continuous increase in CT density during acceleration was observed in the experiment, which may be due to the plasma ionized in the formation region may carry part of the neutral gas into the acceleration region, and these neutral gases will be ionized again. In addition, a significant plasma rotation is observed during the formation process which is introduced by the E*B drift. In this paper, we present the detailed system setup and the preliminary platform test results, hoping to provide some basis for the exploration of the CT technique medium-sized superconducting tokamak device in the future

physics.plasm-ph↗

The Design and Performance of Charged Particle Detector onboard the GECAM Mission

The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new radiation phenomena. GECAM consists of two microsatellites, each equipped with 8 charged particle detectors (CPDs) and 25 gamma-ray detectors (GRDs). The CPD is used to measure charged particles in the space environment, monitor energy and flow intensity changes, and identify between gamma-ray bursts and space charged particle events in conjunction with GRD. CPD uses plastic scintillator as the sensitive material for detection, silicon photomultiplier (SiPM) array as the optically readable device, and the inlaid Am-241 radioactive source as the onboard calibration means. In this paper, we will present the working principle, physical design, functional implementation and preliminary performance test results of the CPD.

astro-ph.IM↗

Quality assurance test and Failure Analysis of SiPM Arrays of GECAM Satellites

The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) satellite consists of two small satellites. Each GECAM payload contains 25 gamma ray detectors (GRD) and 8 charged particle detectors (CPD). GRD is the main detector which can detect gamma-rays and particles and localize the Gamma-Ray Bursts (GRB),while CPD is used to help GRD to discriminate gamma-ray bursts and charged particle bursts. The GRD makes use of lanthanum bromide (LaBr3) crystal readout by SiPM. As the all available SiPM devices belong to commercial grade, quality assurance tests need to be performed in accordance with the aerospace specifications. In this paper, we present the results of quality assurance tests, especially a detailed mechanism analysis of failed devices during the development of GECAM. This paper also summarizes the application experience of commercial-grade SiPM devices in aerospace payloads, and provides suggestions for forthcoming SiPM space applications.

physics.ins-det↗

Dedicated SiPM array for GRD of GECAM

The discovery of gravitational waves and gamma-ray bursts heralds the era of multi-messenger astronomy. With the adoption of two small satellites to achieve the all-sky monitoring of gamma-ray bursts, the gravitational wave high-energy electromagnetic counterpart all-sky monitor (GECAM) possesses a quasi-real-time early warning ability and plays an important role in positioning the sources of gravitational waves and in subsequent observations.

hep-ex↗

Inflight performance of the GECAM Gamma-ray and Charge particle Detectors

The GECAM mission consists of two identical microsatellites (GECAM-A and GECAM-B). Each satellite is equipped with 25 gamma-ray detectors (GRD) and 8 charged particle detectors (CPD). The main scientific objective of the GECAM mission is to detect gamma-ray bursts (GRBs) associated with the gravitational wave events produced by the merging of binary compact stars. After the launch on Dec. 10, 2020 , we carried out a series of on orbit tests. This paper introduces the test results of the GECAM-B satellite. According to the in-flight performance, the energy band for gamma-ray detection of GECAM-B is from about 7 keV to 3.5 MeV. GECAM-B can achieve prompt localization of GRBs. For the first time, GECAM-B realized a quasi-real-time transmission of trigger information using Beidou-3 RDSS. Keywords GECAM, gamma-ray burst, gravitational wave, GRD, CPD

physics.ins-det↗

The SiPM Array Data Acquisition Algorithm Applied to the GECAM Satellite Payload

The Gravitational Wave Burst High-energy Electromagnetic Counterpart All-sky Monitor (GECAM), consists of 2 small satellites that each contain 25 LaBr3 (lanthanum bromide doped with cerium chloride) detectors and 8 plastic scintillator detectors. The detector signals are read out using a silicon photomultiplier (SiPM) array. In this study, an acquisition algorithm for in-orbit real-time SiPM array data is designed and implemented, and the output event packet is defined. Finally, the algorithm's efficacy for event acquisition is verified.

astro-ph.IM↗

Ground-based calibration and characterization of GRD of GECAM: 8-160 keV

As the main detector of the GECAM satellite, the calibration of the energy response and detection efficiency of the GRD detector is the main content of the ground-based calibration. The calibration goal requires the calibrated energy points to sample the full energy range (8 keV-2 MeV) as much as possible. The low energy band (8-160 keV) is calibrated with the X-ray beam, while the high energy band (>160 keV) with radioactive sources. This article mainly focuses on the calibration of the energy response and detection efficiency in the 8-160 keV with a refined measurement around the absorption edges of the lanthanum bromide crystal. The GRD performances for different crystal types, data acquisition modes, working modes, and incident positions are also analyzed in detail. We show that the calibration campaign is comprehensive, and the calibration results are generally consistent with simulations as expected.

astro-ph.IM↗

The design and performance of GRD onboard the GECAM satellite

Background: Each GECAM satellite payload contains 25 gamma-ray detectors (GRDs), which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts (GRBs). GRD was designed using lanthanum bromide (LaBr3) crystal as the sensitive material with the rear end coupled with silicon photomultiplier (SiPM) array for readout. Purpose: In aerospace engineering design of GRD, there are many key points to be studied. In this paper, we present the specific design scheme of GRD, the assembly and the performance test results of detectors. Methods: Based on Monte Carlo simulation and experimental test results, the specific schematic design and assembling process ofGRDwere optimized. After being fully assembled, theGRDswere conducted performance tests by using radioactive source and also conducted random vibration tests. Result and conclusion: The test results show that all satellite-borne GRDs have energy resolution <16% at 59.5 keV, meeting requirements of satellite in scientific performance. The random vibration test shows that GRD can maintain in a stable performance, which meets the requirement of spatial application.

astro-ph.IM↗

GECAM detection of a bright type-I X-ray burst from 4U 0614+09: confirmation its spin frequency at 413 Hz

One month after launching Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM), a bright thermonuclear X-ray burst from 4U~0614+09, was observed on January 24, 2021. We report the time-resolved spectroscopy of the burst and a burst oscillation detection at 413 Hz with a fractional amplitude 3.4\% (rms). This coincides with the burst oscillation previously discovered with \textit{Swift}/BAT \citep{Strohmayer2008}, and therefore confirms the spin frequency of this source. This burst is the brightest one in the normal bursts (except the superburst) ever detected from 4U~0614+09, which leads to an upper limit of distance estimation as 3.1 kpc. The folded light curve during the burst oscillation shows a multi-peak structure, which is the first case observed during a single burst oscillation in nonpulsating sources. The multi-peak profile could be due to additional harmonics of the burst oscillation, which is corresponding to several brighter/fainter spots at the stellar surface.

astro-ph.HE↗

Quenching factor measurements of neon nuclei in neon gas

The NEWS-G collaboration uses Spherical Proportional Counters (SPCs) to search for weakly interacting massive particles (WIMPs). In this paper, we report the first measurements of the nuclear quenching factor in neon gas at \SI{2}{bar} using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modelled using a simple power law: $α$E$_{nr}^β$; we determine its parameters by simultaneously fitting the data collected with the detector over a range of energies. We measured the following parameters in Ne:CH$_{4}$ at \SI{2}{bar}: $α$ = 0.2801 $\pm$ 0.0050 (fit) $\pm$ 0.0045 (sys) and $β$ = 0.0867 $\pm$ 0.020 (fit) $\pm$ 0.006(sys). Our measurements do not agree with expected values from SRIM or Lindhard theory. We demonstrated the feasibility of performing quenching factor measurements at sub-keV energies in gases using SPCs and a neutron beam.

physics.ins-det↗

Characterization of a CMOS pixel sensor for charged particle tracking

A prototype of the CMOS pixel sensor named SUPIX-1 has been fabricated and tested in order to investigate the feasibility of a pixelated tracker for a proposed Higgs factory, namely, the Circular Electron-Positron Collider (CEPC). The sensor, taped out with a 180 nm CMOS Image Sensor (CIS) process, consists of nine different pixel arrays varying in pixel pitches, diode sizes and geometries in order to study the particle detection performance of enlarged pixels. The test was carried out with a Fe-55 radioactive source. Two soft X-ray peaks observed were used to calibrate the charge to voltage factor of the sensor. The pixel-wise equivalent noise charge, charge collection efficiency and signal-to-noise ratio were evaluated. A reconstruction method for clustering pixels of a signal has been developed and the cluster-wise performance was studied as well. The test results show that pixels with the area as large as of $21μ$m$\times 84μ$m have satisfactory noise level and charge collection performance, meeting gerenal requirements for a pixel sensor. This contribution demonstrates that the CMOS pixel sensor with enlarged pitches, using the CIS technology, can be used in tracking for upcoming collider detectors akin to the CEPC.

physics.ins-det↗

Disentangling Electronic, Lattice and Spin Dynamics in the Chiral Helimagnet Cr1/3NbS2

We investigate the static and ultrafast magneto-optical response of the hexagonal chiral helimagnet $Cr_{1/3}NbS_{2}$ above and below the helimagnetic ordering temperature. The presence of a magnetic easy plane contained within the crystallographic ab-plane is confirmed, while degenerate optical pump-probe experiments reveal significant differences in the dynamic between the parent, $NbS_{2}$, and Cr-intercalated compounds. Time resolved magneto-optical Kerr effect measurements show a two-step demagnetization process, where an initial, sub-ps relaxation and subsequent buildup ($τ> 50$ ps) in the demagnetization dynamic scale similarly with increasing pump fluence. Despite theoretical evidence for partial gapping of the minority spin channel, suggestive of possible half metallicity in $Cr_{1/3}NbS_{2}$, such a long demagnetization dynamic likely results from spin lattice-relaxation as opposed to minority state blocking. However, comparison of the two-step demagnetization process in $Cr_{1/3}NbS_{2}$ with other 3d intercalated transition metal dichalcogenides reveals a behavior that is unexpected from conventional spin-lattice relaxation, and may be attributed to the complicated interaction of local moments with itinerant electrons in this material system.

cond-mat.mtrl-sci↗

Quenching Factor consistency across several NaI(Tl) crystals

Testing the DAMA/LIBRA annual modulation result independently of dark matter particle and halo models has been a challenge for twenty years. Using the same target material, NaI(Tl), is required and presently two experiments, ANAIS-112 and COSINE-100, are running for such a goal. A precise knowledge of the detector response to nuclear recoils is mandatory because this is the most likely channel to find the dark matter signal. The light produced by nuclear recoils is quenched with respect to that produced by electrons by a factor that has to be measured experimentally. However, current quenching factor measurements in NaI(Tl) crystals disagree within the energy region of interest for dark matter searches. To disentangle whether this discrepancy is due to intrinsic differences in the light response among different NaI(Tl) crystals, or has its origin in unaccounted for systematic effects will be key in the comparison among the different experiments. We present measurements of the quenching factors for five small NaI(Tl) crystals performed in the same experimental setup to control systematics. Quenching factor results are compatible between crystals and no clear dependence with energy is observed from 10 to 80 keVnr.

astro-ph.IM↗

Jupiter's Temperate Belt/Zone Contrasts Revealed at Depth by Juno Microwave Observations

Juno Microwave Radiometer (MWR) observations of Jupiter's mid-latitudes reveal a strong correlation between brightness temperature contrasts and zonal winds, confirming that the banded structure extends throughout the troposphere. However, the microwave brightness gradient is observed to change sign with depth: the belts are microwave-bright in the $p<5$ bar range and microwave-dark in the $p>10$ bar range. The transition level (which we call the jovicline) is evident in the MWR 11.5 cm channel, which samples the 5-14 bar range when using the limb-darkening at all emission angles. The transition is located between 4 and 10 bars, and implies that belts change with depth from being NH$_3$-depleted to NH$_3$-enriched, or from physically-warm to physically-cool, or more likely a combination of both. The change in character occurs near the statically stable layer associated with water condensation. The implications of the transition are discussed in terms of ammonia redistribution via meridional circulation cells with opposing flows above and below the water condensation layer, and in terms of the `mushball' precipitation model, which predicts steeper vertical ammonia gradients in the belts versus the zones. We show via the moist thermal wind equation that both the temperature and ammonia interpretations can lead to vertical shear on the zonal winds, but the shear is $\sim50\times$ weaker if only NH$_3$ gradients are considered. Conversely, if MWR observations are associated with kinetic temperature gradients then it would produce zonal winds that increase in strength down to the jovicline, consistent with Galileo probe measurements; then decay slowly at higher pressures.

astro-ph.EP↗

Characterization of Muon and Electron Beams in the Paul Scherrer Institute PiM1 Channel for the MUSE Experiment

The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the properties of the beam line established for pions. We discuss the production processes that generate the electron and muon beams, and the simulations of these processes. Simulations of the $π$/$μ$/$e$ beams through the channel using TURTLE and G4beamline are compared. The G4beamline simulation is then compared to several experimental measurements of the channel, including the momentum dispersion at the IFP and target, the shape of the beam spot at the target, and timing measurements that allow the beam momenta to be determined. We conclude that the PiM1 channel can be used for high precision $π$, $μ$, and $e$ scattering.

physics.ins-det↗

The TaichuPix1: A Monolithic Active Pixel Sensor with fast in-pixel readout electronics for the CEPC vertex detector

The proposed Circular Electron Positron Collider (CEPC) imposes new challenges for the vertex detector in terms of high resolution, low material, fast readout and low power. The Monolithic Active Pixel Sensor (MAPS) technology has been chosen as one of the most promising candidates to satisfy these requirements. A MAPS prototype, called TaichuPix1, based on a data-driven structure, together with a column drain readout architecture, benefiting from the ALPIDE and FE-I3 approaches, has been implemented to achieve fast readout. This paper presents the overall architecture of TaichuPix1, the experimental characterization of the FE-I3-like matrix, the threshold dispersion, the noise distribution of the pixels and verifies the charge collection using a radioactive source. These results prove the functionality of the digital periphery and serializer are able to transmit the collected charge to the data interface correctly. Moreover, the individual self-tests of the serializer verify it can work up to about 3 Gbps. And it also indicates that the analog front-end features a fast-rising signal with a short time walk and that the FE-I3-like in-pixel digital logic is properly operating at the 40 MHz system clock.

physics.ins-det↗

A D$_{2}$O detector for flux normalization of a pion decay-at-rest neutrino source

We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2-3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.

physics.ins-det↗

Direct mapping of electronic orbitals in graphene using electron energy-loss spectroscopy

The spatial distributions of anti-bonding $π^\ast$ and $σ^\ast$ states in epitaxial graphene multilayers are mapped using electron energy-loss spectroscopy in a scanning transmission electron microscope. Inelastic channeling simulations validate the interpretation of the spatially-resolved signals in terms of electronic orbitals, and demonstrate the crucial effect of the material thickness on the experimental capability to resolve the distribution of unoccupied states. This work illustrates the current potential of core-level electron energy-loss spectroscopy towards the direct visualization of electronic orbitals in a wide range of materials, of huge interest to better understand chemical bonding among many other properties at interfaces and defects in solids.

cond-mat.mtrl-sci↗