SearcharxivSearch

arXiv subjects

L. Majling

Publications and source records attributed to L. Majling.

6 recordsLinked to original sources

Toward an automated analysis of slow ions in nuclear track emulsion

Application of the nuclear track emulsion technique (NTE) in radioactivity and nuclear fission studies is discussed. It is suggested to use a HSP-1000 automated microscope for searching for a collinear cluster tri-partition of heavy nuclei implanted in NTE. Calibrations of $α$-particles and ion ranges in a novel NTE are carried out. Surface exposures of NTE samples to a ${}^{252}$Cf source started. Planar events containing fragments and long-range $α$-particles as well as fragment triples only are studied. NTE samples are calibrated by ions Kr and Xe of energy of 1.2 and 3 A MeV.

physics.ins-det

Delayed clusters accompanying nonmesonic weak decay of the $Λ$-hypernuclei: a clue to nonleptonic processes

The nonmesonic decay of $Λ$-hypernuclei provides access to the nonleptonic weak decay process $ΛN \to NN$, which is achievable only through the observation of hypernuclear ground-state decays. We continue the discussion of some specific cases which make it possible to detect a few exclusive transitions, namely, the stripping of nucleon from the ground state results in a resonance state decaying via emission of two clusters. Delayed clusters accompanying weak decay of light hypernuclei give a unique information on spin dependence of the weak decay matrix elements.

nucl-th

Performance of HPGe Detectors in High Magnetic Fields

A new generation of high-resolution hypernuclear gamma$-spectroscopy experiments with high-purity germanium detectors (HPGe) are presently designed at the FINUDA spectrometer at DAPhiNE, the Frascati phi-factory, and at PANDA, the antiproton proton hadron spectrometer at the future FAIR facility. Both, the FINUDA and PANDA spectrometers are built around the target region covering a large solid angle. To maximise the detection efficiency the HPGe detectors have to be located near the target, and therefore they have to be operated in strong magnetic fields B ~ 1 T. The performance of HPGe detectors in such an environment has not been well investigated so far. In the present work VEGA and EUROBALL Cluster HPGe detectors were tested in the field provided by the ALADiN magnet at GSI. No significant degradation of the energy resolution was found, and a change in the rise time distribution of the pulses from preamplifiers was observed. A correlation between rise time and pulse height was observed and is used to correct the measured energy, recovering the energy resolution almost completely. Moreover, no problems in the electronics due to the magnetic field were observed.

nucl-ex

New detectors for the kaon and hypernuclear experiments with KaoS at MAMI and with PANDA at GSI

The KaoS spectrometer at the Mainz Microtron MAMI, Germany, is perceived as the ideal candidate for a dedicated spectrometer in kaon and hypernuclei electroproduction. KaoS will be equipped with new read-out electronics, a completely new focal plane detector package consisting of scintillating fibres, and a new trigger system. First prototypes of the fibre detectors and the associated new front-end electronics are shown in this contribution. The Mainz hypernuclei research program will complement the hypernuclear experiments at the planned FAIR facility at GSI, Germany. At the proposed antiproton storage ring the spectroscopy of double Lambda hypernuclei is one of the four main topics which will be addressed by the PANDA Collaboration. The experiments require the operation of high purity germanium (HPGe) detectors in high magnetic fields (B= 1T) in the presence of a large hadronic background. The performance of high resolution Ge detectors in such an environment has been investigated.

nucl-ex

Experimental Investigation of Weak Non-Mesonic Decay of 10Be(Lambda)Hypernuclei at CEBAF

Hypernuclei are convenient laboratory to study the baryon-baryon weak interaction and associated effective Hamiltonian. The strangeness changing process, in which a Lambda hyperon converts to a neutron with a release up to 176 MeV, provides a clear signal for a conversion of an s-quark to a d-quark. We propose to perform a non-mesonic weak decay study of 10Be(Lambda)hypernuclei using the (e,eK) reaction. These investigations will fully utilize the unique parameters of the CEBAF CW electron beam and RF system and are enabled by (1) the use of new detector for alpha particles based on the recently developed RF timing technique with picosecond resolution and (2) the small angle and large acceptance kaon spectrometer-HKS in Hall C.

nucl-ex