SearcharxivSearch

arXiv subjects

L. Manzanillas

Publications and source records attributed to L. Manzanillas.

At least 19 recordsLinked to original sources

Next Generation Multi-element monolithic Germanium detectors for Spectroscopy: First integration at ESRF facility

The XAFS-DET work package of the European LEAPS-INNOV project is developing a high-purity Germanium detectors for synchrotron applications requiring spectroscopic-grade response. The detectors integrate three key features: (1) newly designed monolithic Germanium sensors optimised to mitigate charge-sharing events, (2) an improved cooling and mechanical design structure supported by thermal simulations, and (3) complete electronic chain featuring a low-noise CMOS technology-based preamplifier. enabling high X-ray count rate capability over a broad energy range (5-100 keV). This paper discusses the first integration and characterization of one of the two multi-element Ge detectors at the European Synchrotron Radiation Facility (ESRF). The integration phase included validating high-throughput front-End electronics, integrating them with the Ge sensor, and operating them at liquid nitrogen temperature, in addition to the experimental characterization, which consists of electronics noise study and spectroscopic performance evaluation.

physics.ins-det

Progress in the Development of Multi-Element Monolithic Germanium Detectors in LEAPS-INNOV Project: Insights from Detector Performance Simulation

This study presents a detailed simulation-based analysis of the detection limits of multi-element monolithic Germanium (Ge) detectors to cadmium traces in environmental soil samples. Using the capabilities of the Geant4 Monte Carlo toolkit in combination with the Solid State Detector Package, we evaluated the detection limit variation with the sample-to-detector distances and photon flux. These simulations were conducted to mimic realistic conditions, with a photon flux measured by the SAMBA beamline at the SOLEIL synchrotron facility. Our findings for the detection limit for trace amounts of pollutants in low concentrations like cadmium in the soil provide valuable insights for optimizing experimental setups in environmental monitoring and synchrotron-based applications, where precise detection of trace elements is critical.

physics.ins-det

Search for Very-Short-Baseline Oscillations of Reactor Antineutrinos with the SoLid Detector

In this letter we report the first scientific result based on antineutrinos emitted from the BR2 reactor at SCK CEN. The SoLid experiment uses a novel type of highly granular detector whose basic detection unit combines two scintillators, PVT and 6LiF:ZnS(Ag), to measure antineutrinos via their inverse-beta-decay products. An advantage of PVT is its highly linear response as a function of deposited particle energy. The full-scale detector comprises 12800 voxels and operates over a very short 6.3--8.9 m baseline from the reactor core. The detector segmentation and its 3D imaging capabilities facilitate the extraction of the positron energy from the rest of the visible energy, allowing the latter to be utilised for signal-background discrimination. We present a result based on 280 reactor-on days (55 MW mean power) and 172 reactor-off days, respectively, of live data-taking. A total of 29479 $\pm$ 603 (stat.) antineutrino candidates have been selected, corresponding to an average rate of 105 events per day and a signal-to-background ratio of 0.27. A search for disappearance of antineutrinos to a sterile state has been conducted using complementary model-dependent frequentist and Bayesian fits, providing constraints on the allowed region of the Reactor Antineutrino Anomaly.

hep-ex

An improved limit on the neutrinoless double-electron capture of $^{36}$Ar with GERDA

The GERmanium Detector Array (GERDA) experiment operated enriched high-purity germanium detectors in a liquid argon cryostat, which contains 0.33% of $^{36}$Ar, a candidate isotope for the two-neutrino double-electron capture (2$ν$ECEC) and therefore for the neutrinoless double-electron capture (0$ν$ECEC). If detected, this process would give evidence of lepton number violation and the Majorana nature of neutrinos. In the radiative 0$ν$ECEC of $^{36}$Ar, a monochromatic photon is emitted with an energy of 429.88 keV, which may be detected by the GERDA germanium detectors. We searched for the $^{36}$Ar 0$ν$ECEC with GERDA data, with a total live time of 4.34 yr (3.08 yr accumulated during GERDA Phase II and 1.26 yr during GERDA Phase I). No signal was found and a 90% C.L. lower limit on the half-life of this process was established T$_{1/2}$ > 1.5x10$^{22}$ yr

nucl-ex

Development of an X-ray polarimeter at the SOLEIL Synchrotron

Synchrotron radiation facilities provide highly polarized X-ray beams across a wide energy range. However, the exact type and degree of polarization varies according to the beamline and experimental setup. To accurately determine the angle and degree of linear polarization, a portable X-ray polarimeter has been developed. This setup consists of a Silicon Drift Detector that rotates around a target made of high-density polyethylene. The imprint generated in the angular distribution of scattered photons at a 90-degree angle from the target has been exploited to determine the beam polarization. Measurements were conducted at the GALAXIES beamline of the SOLEIL Synchrotron. The expected angular distribution of the scattered photons for a given beam polarization was obtained through simulations using the Geant4 simulation toolkit. An excellent agreement between simulations and the collected data has been obtained, validating the setup and enabling a precise determination of the beam polarization.

physics.ins-det

Final Results of GERDA on the Two-Neutrino Double-$β$ Decay Half-Life of $^{76}$Ge

We present the measurement of the two-neutrino double-$β$ decay rate of $^{76}$Ge performed with the GERDA Phase II experiment. With a subset of the entire GERDA exposure, 11.8 kg$\cdot$yr, the half-life of the process has been determined: $T^{2ν}_{1/2} = (2.022 \pm 0.018_{stat} \pm 0.038_{sys})\times10^{21}$ yr. This is the most precise determination of the $^{76}$Ge two-neutrino double-$β$ decay half-life and one of the most precise measurements of a double-$β$ decay process. The relevant nuclear matrix element can be extracted: $M^{2ν}_{\text{eff}} = (0.101\pm0.001).$

nucl-ex

Search for tri-nucleon decays of $^{76}$Ge in GERDA

We search for tri-nucleon decays of $^{76}$Ge in the dataset from the GERmanium Detector Array (GERDA) experiment. Decays that populate excited levels of the daughter nucleus above the threshold for particle emission lead to disintegration and are not considered. The ppp-, ppn-, and pnn-decays lead to $^{73}$Cu, $^{73}$Zn, and $^{73}$Ga nuclei, respectively. These nuclei are unstable and eventually proceed by the beta decay of $^{73}$Ga to $^{73}$Ge (stable). We search for the $^{73}$Ga decay exploiting the fact that it dominantly populates the 66.7 keV $^{73m}$Ga state with half-life of 0.5 s. The nnn-decays of $^{76}$Ge that proceed via $^{73m}$Ge are also included in our analysis. We find no signal candidate and place a limit on the sum of the decay widths of the inclusive tri-nucleon decays that corresponds to a lower lifetime limit of 1.2x10$^{26}$ yr (90% credible interval). This result improves previous limits for tri-nucleon decays by one to three orders of magnitude.

nucl-ex

Liquid argon light collection and veto modeling in GERDA Phase II

The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the GERDA experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of $^{76}$Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detection by the novel light read-out system, provides insight into the rejection capability and is a necessary ingredient to obtain robust background predictions. In this paper, we present a model of the GERDA liquid argon veto, as obtained by Monte Carlo simulations and constrained by calibration data, and highlight its application for background decomposition.

physics.ins-det

Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)

Poly Ethylene Naphthalate (PEN) is an industrial polymer plastic which is investigated as a low background, transparent, scintillating and wavelength shifting structural material. PEN scintillates in the blue region and has excellent mechanical properties both at room and cryogenic temperatures. Thus, it is an ideal candidate for active structural components in experiments for the search of rare events like neutrinoless double-beta decay or dark matter recoils. Such optically active structures improve the identification and rejection efficiency of background events, like this improving the sensitivity of experiments. This paper reports on the production of radiopure and transparent PEN plates These structures can be used to mount germanium detectors operating in cryogenic liquids (LAr, LN). Thus, as first application PEN holders will be used to mount the Ge detectors in the LEGEND-200 experiment. The whole process from cleaning the raw material to testing the PEN active components under final operational conditions is reported.

physics.ins-det

Search for exotic physics in double-$β$ decays with GERDA Phase II

A search for Beyond the Standard Model double-$β$ decay modes of $^{76}$Ge has been performed with data collected during the Phase II of the GERmanium Detector Array (GERDA) experiment, located at Laboratori Nazionali del Gran Sasso of INFN (Italy). Improved limits on the decays involving Majorons have been obtained, compared to previous experiments with $^{76}$Ge, with half-life values on the order of 10$^{23}$ yr. For the first time with $^{76}$Ge, limits on Lorentz invariance violation effects in double-$β$ decay have been obtained. The isotropic coefficient $\mathring{a}_\text{of}^{(3)}$, which embeds Lorentz violation in double-$β$ decay, has been constrained at the order of $10^{-6}$ GeV. We also set the first experimental limits on the search for light exotic fermions in double-$β$ decay, including sterile neutrinos.

nucl-ex

Optical properties of low background PEN structural components for the LEGEND-200 experiment

Polyethylene Naphthalate (PEN) plastic scintillator has been identified as potential self-vetoing structural material in low-background physics experiments. Scintillating components have been produced radio-pure from PEN using injection compression molding technology. These low-background PEN components will be used as active holders to mount the Germanium detectors in the \legend-$200$ neutrinoless double beta decay experiment. In this paper we present the measurement of the optical properties of these PEN components. Thus, the emission spectrum, time constant, attenuation and bulk absorption length as well as light output and light yield are reported. In addition, the surface of these PEN components has been characterized and an estimation of the surface roughness is presented. Moreover, the light output of the final \legend-$200$ detector holders has been measured and is reported. These measurements were used to estimate the self-vetoing efficiency of these holders.

physics.ins-det

Detection limit of next-generation of multi-element germanium detectors in the context of Environmental science

One of the main challenges in Environmental sciences is the identification and chemical evolution of polluting traces (e.g, cadmium or antimony) in soil, which requires long acquistion times for accurate measurements at synchrotron facilities. In this context, the potential of a new generation multi-element germanium detectors to identify traces at 0.1-1~ppm in a reasonable time has been studied using Allpix Squared framework. This code has been customized to include the three dimensional electric and weighting field maps generated by COMSOL Multiphysics software, and several features to model the sample environment at SOLEIL synchrotron and the signal response of a germanium detector equipped with a Digital Pulse Processor (DPP). The full simulation chain has been validated by experimental data from SAMBA beamline of SOLEIL synchrotron. This work presents a first estimation of the detection limit to cadmium traces in a soil sample for a future multi-element germanium detector, using this simulation chain.

physics.ins-det

Development of very-thick transparent GEMs with wavelength-shifting capability for noble element TPCs

A new concept for the simultaneous detection of primary and secondary scintillation in time projection chambers is proposed. Its core element is a type of very-thick GEM structure supplied with transparent electrodes and machined from a polyethylene naphthalate plate, a natural wavelength-shifter. Such a device has good prospects for scalability and, by virtue of its genuine optical properties, it can improve on the light collection efficiency, energy threshold and resolution of conventional micropattern gas detectors. This, together with the intrinsic radiopurity of its constituting elements, offers advantages for noble gas and liquid based time projection chambers, used for dark matter searches and neutrino experiments. Production, optical and electrical characterization, and first measurements performed with the new device are reported.

physics.ins-det

Pulse shape analysis in GERDA Phase II

The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge using isotopically enriched high purity germanium detectors at the Laboratori Nazionali del Gran Sasso of INFN. After Phase I (2011-2013), the experiment benefited from several upgrades, including an additional active veto based on LAr instrumentation and a significant increase of mass by point-contact germanium detectors that improved the half-life sensitivity of Phase II (2015-2019) by an order of magnitude. At the core of the background mitigation strategy, the analysis of the time profile of individual pulses provides a powerful topological discrimination of signal-like and background-like events. Data from regular $^{228}$Th calibrations and physics data were both considered in the evaluation of the pulse shape discrimination performance. In this work, we describe the various methods applied to the data collected in GERDA Phase II corresponding to an exposure of 103.7 kg$\cdot$yr. These methods suppress the background by a factor of about 5 in the region of interest around Q$_{ββ}$ = 2039 keV, while preserving (81$\pm$3)% of the signal. In addition, an exhaustive list of parameters is provided which were used in the final data analysis.

physics.ins-det

Neutrino Physics with an Opaque Detector

In 1956 Reines & Cowan discovered the neutrino using a liquid scintillator detector. The neutrinos interacted with the scintillator, producing light that propagated across transparent volumes to surrounding photo-sensors. This approach has remained one of the most widespread and successful neutrino detection technologies used since. This article introduces a concept that breaks with the conventional paradigm of transparency by confining and collecting light near its creation point with an opaque scintillator and a dense array of optical fibres. This technique, called LiquidO, can provide high-resolution imaging to enable efficient identification of individual particles event-by-event. A natural affinity for adding dopants at high concentrations is provided by the use of an opaque medium. With these and other capabilities, the potential of our detector concept to unlock opportunities in neutrino physics is presented here, alongside the results of the first experimental validation.

physics.ins-det

Characterization of inverted coaxial $^{76}$Ge detectors in GERDA for future double-$β$ decay experiments

Neutrinoless double-$β$ decay of $^{76}$Ge is searched for with germanium detectors where source and detector of the decay are identical. For the success of future experiments it is important to increase the mass of the detectors. We report here on the characterization and testing of five prototype detectors manufactured in inverted coaxial (IC) geometry from material enriched to 88% in $^{76}$Ge. IC detectors combine the large mass of the traditional semi-coaxial Ge detectors with the superior resolution and pulse shape discrimination power of point contact detectors which exhibited so far much lower mass. Their performance has been found to be satisfactory both when operated in vacuum cryostat and bare in liquid argon within the GERDA setup. The measured resolutions at the Q-value for double-$β$ decay of $^{76}$Ge (Q$_{ββ}$ = 2039 keV) are about 2.1 keV full width at half maximum in vacuum cryostat. After 18 months of operation within the ultra-low background environment of the GERmanium Detector Array (GERDA) experiment and an accumulated exposure of 8.5 kg$\cdot$yr, the background index after analysis cuts is measured to be $4.9^{+7.3}_{-3.4}\times 10^{-4}$ counts /(keV$\cdot$kg$\cdot$yr) around Q$_{ββ}$. This work confirms the feasibility of IC detectors for the next-generation experiment LEGEND.

physics.ins-det

Calibration of the GERDA experiment

The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge with an array of about 40 high-purity isotopically-enriched germanium detectors. The experimental signature of the decay is a monoenergetic signal at Q$_{ββ}$ = 2039.061(7)keV in the measured summed energy spectrum of the two emitted electrons. Both the energy reconstruction and resolution of the germanium detectors are crucial to separate a potential signal from various backgrounds, such as neutrino-accompanied double-$β$ decays allowed by the Standard Model. The energy resolution and stability were determined and monitored as a function of time using data from regular $^{228}$Th calibrations. In this work, we describe the calibration process and associated data analysis of the full GERDA dataset, tailored to preserve the excellent resolution of the individual germanium detectors when combining data over several years.

physics.ins-det

SoLid: A short baseline reactor neutrino experiment

The SoLid experiment, short for Search for Oscillations with a Lithium-6 detector, is a new generation neutrino experiment which tries to address the key challenges for high precision reactor neutrino measurements at very short distances from a reactor core and with little or no overburden. The primary goal of the SoLid experiment is to perform a precise measurement of the electron antineutrino energy spectrum and flux and to search for very short distance neutrino oscillations as a probe of eV-scale sterile neutrinos. This paper describes the SoLid detection principle, the mechanical design and the construction of the detector. It then reports on the installation and commissioning on site near the BR2 reactor, Belgium, and finally highlights its performance in terms of detector response and calibration.

physics.ins-det