SearcharxivSearch

arXiv subjects

L. Martin

Publications and source records attributed to L. Martin.

At least 19 recordsLinked to original sources

Euclid preparation. Overview of Euclid infrared detector performance from ground tests

The paper describes the objectives, design and findings of the pre-launch ground characterisation campaigns of the Euclid infrared detectors. The pixel properties, including baseline, bad pixels, quantum efficiency, inter pixel capacitance, quantum efficiency, dark current, readout noise, conversion gain, response nonlinearity, and image persistence were measured and characterised for each pixel. We describe in detail the test flow definition that allows us to derive the pixel properties and we present the data acquisition and data quality check software implemented for this purpose. We also outline the measurement protocols of all the pixel properties presented and we provide a comprehensive overview of the performance of the Euclid infrared detectors as derived after tuning the operating parameters of the detectors. The main conclusion of this work is that the performance of the infrared detectors Euclid meets the requirements. Pixels classified as non-functioning accounted for less than 0.2% of all science pixels. IPC coupling is minimal and crosstalk between adjacent pixels is less than 1% between adjacent pixels. 95% of the pixels show a QE greater than 80% across the entire spectral range of the Euclid mission. The conversion gain is approximately 0.52 ADU/e-, with a variation less than 1% between channels of the same detector. The reset noise is approximately equal to 23 ADU after reference pixels correction. The readout noise of a single frame is approximately 13 $e^-$ while the signal estimator noise is measured at 7 $e^-$ in photometric mode and 9 $e^-$ in spectroscopic acquisition mode. The deviation from linear response at signal levels up to 80 k$e^-$ is less than 5% for 95% of the pixels. Median persistence amplitudes are less than 0.3% of the signal, though persistence exhibits significant spatial variation and differences between detectors.

astro-ph.IM

First results of AUP Nb3Sn quadrupole horizontal tests

The Large Hadron Collider will soon undergo an upgrade to increase its luminosity by a factor of ~10 [1]. A crucial part of this upgrade will be replacement of the NbTi focusing magnets with Nb3Sn magnets that achieve a ~50% increase in the field strength. This will be the first ever large-scale implementation of Nb3Sn magnets in a particle accelerator. The High-Luminosity LHC Upgrade, HL-LHC is a CERN project with a world-wide collaboration. It is under construction and utilizes Nb3Sn Magnets (named MQXF) as key ingredients to increase tenfold the integrated luminosity delivered to the CMS and ATLAS experiments in the next decade. The HL-LHC AUP is the US effort to contribute approximately 50% of the low-beta focusing magnets and crab cavities for the HL-LHC. This paper will present the program to fabricate the Nb3Sn superconducting magnets. We are reporting the status of the HL-LHC AUP project present the results from horizontal tests of the first fully assembled cryo-assembly.

physics.acc-ph

Euclid. III. The NISP Instrument

The Near-Infrared Spectrometer and Photometer (NISP) on board the Euclid satellite provides multiband photometry and R>=450 slitless grism spectroscopy in the 950-2020nm wavelength range. In this reference article we illuminate the background of NISP's functional and calibration requirements, describe the instrument's integral components, and provide all its key properties. We also sketch the processes needed to understand how NISP operates and is calibrated, and its technical potentials and limitations. Links to articles providing more details and technical background are included. NISP's 16 HAWAII-2RG (H2RG) detectors with a plate scale of 0.3" pix^-1 deliver a field-of-view of 0.57deg^2. In photo mode, NISP reaches a limiting magnitude of ~24.5AB mag in three photometric exposures of about 100s exposure time, for point sources and with a signal-to-noise ratio (SNR) of 5. For spectroscopy, NISP's point-source sensitivity is a SNR = 3.5 detection of an emission line with flux ~2x10^-16erg/s/cm^2 integrated over two resolution elements of 13.4A, in 3x560s grism exposures at 1.6 mu (redshifted Ha). Our calibration includes on-ground and in-flight characterisation and monitoring of detector baseline, dark current, non-linearity, and sensitivity, to guarantee a relative photometric accuracy of better than 1.5%, and relative spectrophotometry to better than 0.7%. The wavelength calibration must be better than 5A. NISP is the state-of-the-art instrument in the NIR for all science beyond small areas available from HST and JWST - and an enormous advance due to its combination of field size and high throughput of telescope and instrument. During Euclid's 6-year survey covering 14000 deg^2 of extragalactic sky, NISP will be the backbone for determining distances of more than a billion galaxies. Its NIR data will become a rich reference imaging and spectroscopy data set for the coming decades.

astro-ph.IM

A multi-shot target-wheel assembly for high-repetition-rate, laser-driven proton acceleration

A multi-shot target assembly and automatic alignment procedure for laser-plasma proton acceleration at high-repetition-rate are introduced. The assembly is based on a multi-target rotating wheel capable of hosting $>$5000 targets, mounted on a three-dimensional motorised stage to allow rapid replenishment and alignment of the target material between laser irradiations. The automatic alignment procedure consists of a detailed mapping of the impact positions at the target surface prior to the irradiation that ensures stable operation of the target, which alongside the purpose-built design of the target wheel, enable the operation at rates up to 10 Hz. Stable and continuous laser-driven proton acceleration is demonstrated, with observed cut-off energy stability about 15%.

physics.plasm-ph

Euclid Near Infrared Spectrometer and Photometer instrument flight model presentation, performance and ground calibration results summary

The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments. It operates in the near-IR spectral region (950-2020nm) as a photometer and spectrometer. The instrument is composed of: a cold (135 K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly, a filter wheel mechanism, a grism wheel mechanism, a calibration unit, and a thermal control system, a detection system based on a mosaic of 16 H2RG with their front-end readout electronic, and a warm electronic system (290 K) composed of a data processing / detector control unit and of an instrument control unit that interfaces with the spacecraft via a 1553 bus for command and control and via Spacewire links for science data. This paper presents: the final architecture of the flight model instrument and subsystems, and the performance and the ground calibration measurement done at NISP level and at Euclid Payload Module level at operational cold temperature.

astro-ph.IM

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$\nu \beta \beta$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$\nu \beta \beta$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.

physics.ins-det

Characterization and performance of the Apollon Short-Focal-Area facility following its commissioning at 1 PW level

We present the results of the first commissioning phase of the ``short focal length'' area (SFA) of the Apollon laser facility (located in Saclay, France), which was performed with the first available laser beam (F2), scaled to a nominal power of one petawatt. Under the conditions that were tested, this beam delivered on target pulses of 10 J average energy and 24 fs duration. Several diagnostics were fielded to assess the performance of the facility. The on-target focal spot, its spatial stability, the temporal intensity profile prior to the main pulse, as well as the resulting density gradient formed at the irradiated side of solid targets, have been thoroughly characterized, with the goal of helping users design future experiments. Emissions of energetic electrons, ions, and electromagnetic radiation were recorded, showing good laser-to-target coupling efficiency and an overall performance comparable with that of similar international facilities. This will be followed in 2022 by a further commissioning stage at the multi-petawatt level.

physics.plasm-ph

Characterisation of SiPM Photon Emission in the Dark

In this paper, we report on the photon emission of Silicon Photomultipliers (SiPMs) from avalanche pulses generated in dark condition, with the main objective of better understanding the associated systematics for next-generation, large area, SiPM-based physics experiments. A new apparatus for spectral and imaging analysis was developed at TRIUMF and used to measure the light emitted by the two SiPMs considered as photo-sensor candidates for the nEXO neutrinoless double-beta decay experiment: one Fondazione Bruno Kessler (FBK) VUV-HD Low Field (LF) Low After Pulse (Low AP) (VUV-HD3) SiPM, and one Hamamatsu Photonics K.K. (HPK) VUV4 Multi-Pixel Photon Counter (MPPC). Spectral measurements of their light emission were taken with varying over-voltage in the wavelength range of 450--1020\,nm. For the FBK VUV-HD3, at an over-voltage of $12.1\pm1.0$\,V, we measure a secondary photon yield (number of photons ($\gamma$) emitted per charge carrier ($e^{-}$)) of $(4.04\pm0.02)\times 10^{-6}$ $\gamma/e^{-}$. The emission spectrum of the FBK VUV-HD3 contains an interference pattern consistent with thin-film interference. Additionally, emission microscopy images (EMMIs) of the FBK VUV-HD3 show a small number of highly localized regions with increased light intensity (hotspots) randomly distributed over the SiPM surface area. For the HPK VUV4 MPPC, at an over-voltage of $10.7\pm1.0$\,V, we measure a secondary photon yield of $(8.71\pm0.04)\times 10^{-6}$ $\gamma/e^{-}$. In contrast to the FBK VUV-HD3, the emission spectra of the HPK VUV4 don't show an interference pattern -- most likely due to a thinner surface coating. EMMIs of the HPK VUV4 also reveal a larger number of hotspots compared to the FBK VUV-HD3, especially in one of the corners of the device.

physics.ins-det

Non-Equilibrium Dynamics in Two-Color, Few-Photon Dissociative Excitation and Ionization of D$_2$

D$_2$ molecules, excited by linearly cross-polarized femtosecond extreme ultraviolet (XUV) and near-infrared (NIR) light pulses, reveal highly structured D$^+$ ion fragment momenta and angular distributions that originate from two different 4-step dissociative ionization pathways after four photon absorption (1 XUV + 3 NIR). We show that, even for very low dissociation kinetic energy release $\le$~240~meV, specific electronic excitation pathways can be identified and isolated in the final ion momentum distributions. With the aid of {\it ab initio} electronic structure and time-dependent Schr\"odinger equation calculations, angular momentum, energy, and parity conservation are used to identify the excited neutral molecular states and molecular orientations relative to the polarization vectors in these different photoexcitation and dissociation sequences of the neutral D$_2$ molecule and its D$_2^+$ cation. In one sequential photodissociation pathway, molecules aligned along either of the two light polarization vectors are excluded, while another pathway selects molecules aligned parallel to the light propagation direction. The evolution of the nuclear wave packet on the intermediate \Bstate electronic state of the neutral D$_2$ molecule is also probed in real time.

physics.atom-ph

Pulsars with NenuFAR: backend and pipelines

NenuFAR (New extension in Nan\c{c}ay upgrading LoFAR) is a new radio telescope developed and built on the site of the Nan\c{c}ay Radio Observatory. It is designed to observe the largely unexplored frequency window from 10 to 85\,MHz, offering a high sensitivity across its full bandwidth. NenuFAR has started its "early science" operation in July 2019, with 58\% of its final collecting area being available. Pulsars are one of the major topics for the scientific exploitation of this frequency range and represent an important challenge in terms of instrumentation. Designing instrumentation at these frequencies is complicated by the need to compensate for the effects of both the interstellar medium and the ionosphere on the observed signal. Our real-time pipeline LUPPI (Low frequency Ultimate Pulsar Processing Instrumentation) is able to cope with a high data rate and to provide real-time coherent de-dispersion down to the lowest frequencies reached by NenuFAR (10\,MHz). The full backend functionality is described, as well as the main pulsar observing modes (folded, single-pulse, waveform, and dynamic spectrum). This instrumentation allowed us to detect 172 pulsars in our first targeted search below 85\,MHz, including 10 millisecond pulsars (6 of which detected for the first time below 100 MHz). We also present some of the "early science" results of NenuFAR on pulsars: a high frequency resolution mapping of PSR B1919$+$21's emission profile and a detailed observation of single-pulse sub-structures from PSR~B0809$+$74 down to 16\,MHz, the high rate of giant-pulse emission from the Crab pulsar detected at 68.7\,MHz (43 events/min), and the illustration of the very good timing performance of the instrumentation, allowing us to study dispersion measure variations in great detail.

astro-ph.IM

Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic

Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.

physics.med-ph

Effects of Electron Correlations and Chemical Pressures on Superconductivity of $\beta^{\prime\prime}$-type Organic Compounds

We investigate low-temperature electronic states of the series of organic conductors $\beta^{\prime\prime}$-(BEDT-TTF)$_4$[(H$_3$O)M(C$_2$O$_4$)$_3$]G, where BEDT-TTF is bis(ethylenedithio)tetrathiafulvalene, and M and G represent trivalent metal ions and guest organic molecules, respectively. Our structural analyses reveal that the replacement of M and G give rise to systematic change in the cell parameters, especially in the $b$-axis length, which has positive correlation with the superconducting transition temperature $T_{\rm c}$. Analyses of temperature and magnetic field dependences of the electrical resistance including the Shubnikov-de Haas oscillations elucidates that the variation of charge disproportionation, effective mass and the number of itinerant carriers, can be systematically explained by the change of the $b$-axis length. The changes of the transfer integrals induced by stretching/compressing the $b$-axis are confirmed by the band calculation. We discuss that electron correlations in quarter-filled electronic bands lead to charge disproportionation and the possibility of a novel pairing mechanism of superconductivity mediated by charge degrees of freedom.

cond-mat.str-el

A direct measurement of the 17O(a,g)21Ne reaction in inverse kinematics and its impact on heavy element production

During the slow neutron capture process in massive stars, reactions on light elements can both produce and absorb neutrons thereby influencing the final heavy element abundances. At low metallicities, the high neutron capture rate of 16-O can inhibit s-process nucleosynthesis unless the neutrons are recycled via the 17O(a,n)20Ne reaction. The efficiency of this neutron recycling is determined by competition between the 17O(a,n)20Ne and 17O(a,g)21Ne reactions. While some experimental data are available on the former reaction, no data exist for the radiative capture channel at the relevant astrophysical energies. The 17O(a,g)21Ne reaction has been studied directly using the DRAGON recoil separator at the TRIUMF Laboratory. The reaction cross section has been determined at energies between 0.6 and 1.6 MeV Ecm, reaching into the Gamow window for core helium burning for the first time. Resonance strengths for resonances at 0.63, 0.721, 0.81 and 1.122 MeV Ecm have been extracted. The experimentally based reaction rate calculated represents a lower limit, but suggests that significant s-process nucleosynthesis occurs in low metallicity massive stars.

nucl-ex

Computing the electric field from Extensive Air Showers using a realistic description of the atmosphere

The composition of ultra-high energy cosmic rays is still poorly known and constitutes a very important topic in the field of high-energy astrophysics. Detection of ultra-high energy cosmic rays is carried out via the extensive air showers they create after interacting with the atmosphere constituents. The secondary electrons and positrons within the showers emit a detectable electric field in the kHz-GHz range. It is possible to use this radio signal for the estimation of the atmospheric depth of maximal development of the showers \xmax, with a good accuracy and a duty cycle close to $100\%$. This value of \xmax\ is strongly correlated to the nature of the primary cosmic ray that initiated the shower. We show in this paper the importance of using a realistic atmospheric model in order to correct for systematic errors that can prevent a correct and unbiased estimation of~\xmax.

astro-ph.HE

Stabilizing entanglement via symmetry-selective bath engineering in superconducting qubits

Bath engineering, which utilizes coupling to lossy modes in a quantum system to generate non-trivial steady states, is a tantalizing alternative to gate- and measurement-based quantum science. Here, we demonstrate dissipative stabilization of entanglement between two superconducting transmon qubits in a symmetry-selective manner. We utilize the engineered symmetries of the dissipative environment to stabilize a target Bell state; we further demonstrate suppression of the Bell state of opposite symmetry due to parity selection rules. This implementation is resource-efficient, achieves a steady-state fidelity $\mathcal{F} = 0.70$, and is scalable to multiple qubits.

quant-ph

High-precision measurements of extensive air showers with the SKA

As of 2023, the Square Kilometre Array will constitute the world's largest radio telescope, offering unprecedented capabilities for a diverse science programme in radio astronomy. At the same time, the SKA will be ideally suited to detect extensive air showers initiated by cosmic rays in the Earth's atmosphere via their radio emission. With its very dense and uniform antenna spacing in a fiducial area of one km$^2$ and its large bandwidth of 50-350 MHz, the low-frequency part of the SKA will provide very precise measurements of individual cosmic ray air showers. These precision measurements will allow detailed studies of the mass composition of cosmic rays in the energy region of transition from a Galactic to an extragalactic origin. Also, the SKA will facilitate three-dimensional "tomography" of the electromagnetic cascades of air showers, allowing the study of particle interactions at energies beyond the reach of the LHC. Finally, studies of possible connections between air showers and lightning initiation can be taken to a new level with the SKA. We discuss the science potential of air shower detection with the SKA and report on the technical requirements and project status.

astro-ph.IM

The Mid-Infrared Instrument for the James Webb Space Telescope, III: MIRIM, The MIRI Imager

In this article, we describe the MIRI Imager module (MIRIM), which provides broad-band imaging in the 5 - 27 microns wavelength range for the James Webb Space Telescope. The imager has a 0"11 pixel scale and a total unobstructed view of 74"x113". The remainder of its nominal 113"x113" field is occupied by the coronagraphs and the low resolution spectrometer. We present the instrument optical and mechanical design. We show that the test data, as measured during the test campaigns undertaken at CEA-Saclay, at the Rutherford Appleton Laboratory, and at the NASA Goddard Space Flight Center, indicate that the instrument complies with its design requirements and goals. We also discuss the operational requirements (multiple dithers and exposures) needed for optimal scientific utilization of the MIRIM.

astro-ph.IM

Precision measurements of cosmic ray air showers with the SKA

Supplemented with suitable buffering techniques, the low-frequency part of the SKA can be used as an ultra-precise detector for cosmic-ray air showers at very high energies. This would enable a wealth of scientific applications: the physics of the transition from Galactic to extragalactic cosmic rays could be probed with very high precision mass measurements, hadronic interactions could be studied up to energies well beyond the reach of man-made particle accelerators, air shower tomography could be performed with very high spatial resolution exploiting the large instantaneous bandwidth and very uniform instantaneous $u$-$v$ coverage of SKA1-LOW, and the physics of thunderstorms and possible connections between cosmic rays and lightning initiation could be studied in unprecedented levels of detail. In this article, we describe the potential of the SKA as an air shower radio detector from the perspective of existing radio detection efforts and discuss the associated technical requirements.

astro-ph.IM