Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment

The NUCLEUS experiment aims to study coherent elastic neutrino-nucleus scattering (CE$\nu$NS) of reactor electron antineutrinos at the Chooz nuclear power plant in France. In this work, the cryogenic target-detector module for the NUCLEUS Technical Run was developed and commissioned at the Technical University of Munich. The module comprises four gram-scale CaWO$_4$ detectors, each equipped with two Transition Edge Sensors (TES), providing a total target mass of 6.96 g. We present the design, integration, detector characterization, and X-ray-based energy calibration of these detectors. Across six characterized detectors, a mean baseline resolution of $\overline{\sigma}_{\mathrm{BL}} = (2.79 \pm 0.60)\,\mathrm{eV}$ was achieved. The best-performing detector reached $\sigma_{\mathrm{BL}} = (2.16 \pm 0.02_{\mathrm{stat}})\,\mathrm{eV}$, surpassing the design goal by a factor of two and representing a state-of-the-art result for a cryogenic CaWO$_4$ detector. The target detector module was successfully operated simultaneously with the surrounding Cryogenic Outer Veto, which consists of six kg-scale Ge detectors for background discrimination, showing no measurable cross-talk. These results demonstrate the readiness of the target-detector system for the NUCLEUS Technical Run at Chooz and mark a key milestone in the development of cryogenic detectors for reactor-CE$\nu$NS measurements.

physics.ins-det

New limits on the Pauli forbidden transitions in 12C nuclei obtained with the complete Borexino dataset

The Pauli exclusion principle (PEP) was tested for nucleons in $\rm{^{12}C}$ nuclei using the Borexino dataset from 2007 to 2021. %the complete Borexino detector data. The approach consists of searching for $\gamma$-quanta, neutrons, protons, as well as electrons and positrons emitted in non-Paulian transitions of nucleons from the $1P_{3/2}$ shell to the filled $1S_{1/2}$ shell. Due to the uniquely low background level, the large mass, and long measurement time of the Borexino detector, the most stringent experimental constraints to date on the lifetime of the $\rm{^{12}C}$ nucleus with respect to PEP-forbidden transitions were obtained: $\tau({^{12}\rm{C}}\rightarrow{^{12}\widetilde{\rm{C}}}+\gamma) \geq {1.1\times10^{32}}$ y, $\tau({^{12}\rm{C}}\rightarrow{^{11}\widetilde{\rm{B}}}+ p) \geq {1.0\times10^{31}}$ y, $\tau({^{12}\rm{C}}\rightarrow{^{11}\widetilde{\rm{C}}}+ n) \geq 2.0 \times 10^{31}$ y, $\tau({^{12}\rm{C}}\rightarrow{^{12}\widetilde{\rm{N}}}+ e^- + \widetilde{\nu_e}) \geq 6.4 \times 10^{30}$ y and $\tau({^{12}\rm{C}}\rightarrow{^{12}\widetilde{\rm{B}}}+ e^+ + \nu_e) \geq 6.6 \times 10^{30}$ y (90\% C.L.). The upper limits on the relative strengths for the non-Paulian electromagnetic, strong, and weak transitions have been obtained: $\delta^2_{\gamma}\leq 1.0\times 10^{-57}$, $\delta^2_{N}\leq 7.0\times 10^{-61}$ and $\delta^2_{\beta}\leq 9.6\times 10^{-36}$, all at 90\% C.L..

nucl-ex

Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment

Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving the best sensitivity for this kind of detectors is crucial for signal identification, leading to various optimization techniques. In this work, we present two complementary methods to increase the sensitivity of cryogenic detectors read out by transition-edge sensors, developed and tested in the context of the NUCLEUS experiment. The first procedure maps the signal-to-noise ratio of the device across a wide range of operating points, to identify the configuration with maximal sensitivity to be used during data taking. The second method exploits the double readout of the detector, combining the information on different channels with a two-dimensional optimum filter analysis that effectively lowers the energy threshold. With both techniques at the same time, we obtained a baseline resolution of 2.94 $\pm$ 0.05 (stat) eV using a CaWO4 based detector, achieving a promising result in view of the first run of NUCLEUS at the experimental site.

physics.ins-det

Prospect of the NUCLEUS Experiment at Chooz for Coherent Elastic Neutrino-Nucleus Scattering and New Physics Searches

The NUCLEUS experiment aims to measure coherent elastic neutrino-nucleus scattering (CE$\nu$NS) at unprecedentedly low nuclear recoil energies using gram-scale cryogenic calorimeters operated at the Chooz nuclear power plant in France. Access to recoil energies at the $\mathcal{O}(10~\mathrm{eV})$ scale enables CE$\nu$NS studies at extremely low momentum transfer and provides enhanced sensitivity to new physics. In this work, we present sensitivity projections for the upcoming NUCLEUS technical and physics runs, incorporating a data-driven treatment of the low-energy excess (LEE) observed during commissioning. We develop a likelihood framework that exploits reactor-power variation to disentangle signal and background in a low signal-to-background regime and to assess the impact of the dominant systematic uncertainties. For the Technical Run with a 7 g CaWO$_4$ target, we find competitive sensitivity to several scenarios beyond the Standard Model, which do not require a CE$\nu$NS observation. For the Physics Run, assuming complete suppression of the LEE, we project a 4.7 $\sigma$ observation of CE$\nu$NS with a statistical precision of about 20 % in 1 year, enabling a determination of the weak mixing angle at the lowest momentum transfer probed to date with CE$\nu$NS and leading CE$\nu$NS-based constraints on the neutrino charge radius and new mediator models.

hep-ex

Characterization of the Low Energy Excess using a NUCLEUS Al$_{2}$O$_{3}$ detector

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $(-0.59 \pm 0.06)$, when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment.

physics.ins-det

Constraints on non-standard neutrino interactions from Borexino extended data-set

Neutrino non-standard interactions (NSI) constitute an active research field, as they are closely related to potential new physics associated with dark matter searches and exotic interactions arising from fundamental symmetry violations. The Borexino's unprecedented sensitivity to solar neutrinos, derived from its low background and precision spectral measurements, enables stringent constraints on potential deviations from the standard three-flavor neutrino oscillation paradigm. This work presents an update on the analysis of flavor-diagonal NSI using the full Borexino Phase-III data set, extending the study previously reported in Constraints on flavor-diagonal non-standard neutrino interactions from Borexino Phase-II (JHEP 2020, 38). The updated analysis incorporates the extended temporal and statistical coverage of Phase-III. The results indicate improved sensitivity to the diagonal NSI parameters, with constraints exceeding those obtained in Phase-II. Furthermore, a more general analysis that includes all possible off-diagonal NSI terms is presented for the first time, providing a comprehensive exploration of the NSI parameter space associated with the flavors of the incoming and outgoing neutrinos. This work once again underlines Borexino's critical role in probing new physics scenarios and reinforces its legacy in neutrino research. Detailed comparisons with Phase-II results are discussed, along with implications for theoretical models of NSI.

hep-ex

First Measurement of Neutrino Emissions from Spent Nuclear Fuel by the Double Chooz Experiment

Neutrino emission from nuclear reactors provides real-time insights into reactor power and fuel evolution, with potential applications in monitoring and nuclear safeguards. Following reactor shutdown, a low-intensity flux of ``residual neutrinos'' persists due to the decay of long-lived fission isotopes in the partially burnt fuel remaining within the reactor cores and in spent nuclear fuel stored in nearby cooling pools. The Double Chooz experiment at the Chooz B nuclear power plant in France achieved the first quantitative measurement of this residual flux based on 17.2 days of reactor-off data. In the energy range where the residual signal is most pronounced, the neutrino detector located 400$\,$m from the cores recorded $106 \pm 18$ neutrino candidate events (5.9$\sigma$ significance). This measurement is in excellent agreement with the predicted value of $88 \pm 7$ events derived from detailed reactor simulations modeling the decay activities of fission products and incorporating the best-available models of neutrino spectra.

hep-ex

Particle background characterization and prediction for the NUCLEUS reactor CE$\nu$NS experiment

NUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino-Nucleus Scattering (CE$\nu$NS) and to search for new physics at the Chooz nuclear power plant in France. This article reports on the prediction of particle-induced backgrounds, especially focusing on the sub-keV energy range, which is a poorly known region where most of the CE$\nu$NS signal from reactor antineutrinos is expected. Together with measurements of the environmental background radiations at the experimental site, extensive Monte Carlo simulations based on the Geant4 package were run both to optimize the experimental setup for background reduction and to estimate the residual rates arising from different contributions such as cosmic ray-induced radiations, environmental gammas and material radioactivity. The NUCLEUS experimental setup is predicted to achieve a total rejection power of more than two orders of magnitude, leaving a residual background component which is strongly dominated by cosmic ray-induced neutrons. In the CE$\nu$NS signal region of interest between 10 and 100 eV, a total particle background rate of $\sim$ 250 d$^{-1}$kg$^{-1}$keV$^{-1}$ is expected in the CaWO$_4$ target detectors. This corresponds to a signal-to-background ratio $\gtrsim$ 1, and therefore meets the required specifications in terms of particle background rejection for the detection of reactor antineutrinos through CE$\nu$NS.

physics.ins-det

Commissioning of the NUCLEUS Experiment at the Technical University of Munich

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO$_4$ targets in the fully coherent regime, using gram-scale cryogenic calorimeters. The experimental apparatus will be installed at the Chooz nuclear power plant in France, in the vicinity of two 4.25 GW$_{\text{th}}$ reactor cores. This work presents results from the commissioning of an essential version of the experiment at the shallow Underground Laboratory of the Technical University of Munich. For the first time, two cryogenic target detectors were tested alongside active and passive shielding systems. Over a period of two months all detector subsystems were operated with stable performance. Background measurements were conducted, providing important benchmarks for the modeling of background sources at the reactor site. Finally, we present ongoing efforts to upgrade the detector systems in preparation for a technical run at Chooz in 2026, and highlight the remaining challenges to achieving neutrino detection.

hep-ex

Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source

Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677\,eV to 6.5\,keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 gram CaWO$_4$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).

physics.ins-det

Decoupling Pulse Tube Vibrations from a Dry Dilution Refrigerator at milli-Kelvin Temperatures

With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low $(6.22 \pm 0.07)$ eV baseline resolution on a gram-scale CaWO$_4$ cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.

physics.ins-det

Novel techniques for alpha/beta pulse shape discrimination in Borexino

Borexino could efficiently distinguish between alpha and beta radiation in its liquid scintillator by the characteristic time profile of their scintillation pulse. This alpha/beta discrimination, first demonstrated at the tonne scale in the Counting Test Facility prototype, was used throughout the lifetime of the experiment between 2007 and 2021. With this method, alpha events are identified and subtracted from the beta-like solar neutrino events. This is particularly important in liquid scintillator as alpha scintillation is quenched many-fold. In Borexino, the prominent Po-210 decay peak was a background in the energy range of electrons scattered from Be-7 solar neutrinos. Optimal alpha-beta discrimination was achieved with a "multi-layer perceptron neural network", which its higher ability to leverage the timing information of the scintillation photons detected by the photomultiplier tubes. An event-by-event, high efficiency, stable, and uniform pulse shape discrimination was essential in characterising the spatial distribution of background in the detector. This benefited most Borexino measurements, including solar neutrinos in the \pp chain and the first direct observation of the CNO cycle in the Sun. This paper presents the key milestones in alpha/beta discrimination in Borexino as a term of comparison for current and future large liquid scintillator detectors

hep-ex

A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures

Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we developed a cryogenic muon veto equipped with wavelength shifting fibers and a silicon photo multiplier operating inside a dilution refrigerator. The achievable compactness of cryostat-internal integration is a key factor in keeping the muon rate to a minimum while maximizing coverage. The thermal and light output properties of a plastic scintillation detector were examined. We report first data on the thermal conductivity and heat capacity of the polystyrene-based scintillator UPS-923A over a wide range of temperatures extending below one Kelvin. The light output was measured down to 0.8K and observed to increase by a factor of 1.61$\pm$0.05 compared to 300K. The development of an organic plastic scintillation muon veto operating in sub-Kelvin temperature environments opens new perspectives for rare-event searches with cryogenic detectors at sites lacking substantial overburden.

physics.ins-det

Final results of Borexino on CNO solar neutrinos

We report the first measurement of CNO solar neutrinos by Borexino that uses the Correlated Integrated Directionality (CID) method, exploiting the sub-dominant Cherenkov light in the liquid scintillator detector. The directional information of the solar origin of the neutrinos is preserved by the fast Cherenkov photons from the neutrino scattered electrons, and is used to discriminate between signal and background. The directional information is independent from the spectral information on which the previous CNO solar neutrino measurements by Borexino were based. While the CNO spectral analysis could only be applied on the Phase-III dataset, the directional analysis can use the complete Borexino data taking period from 2007 to 2021. The absence of CNO neutrinos has been rejected with >5σ credible level using the Bayesian statistics. The directional CNO measurement is obtained without an external constraint on the $^{210}$Bi contamination of the liquid scintillator, which was applied in the spectral analysis approach. The final and the most precise CNO measurement of Borexino is then obtained by combining the new CID-based CNO result with an improved spectral fit of the Phase-III dataset. Including the statistical and the systematic errors, the extracted CNO interaction rate is $R(\mathrm{CNO})=6.7^{+1.2}_{-0.8} \, \mathrm{cpd/100 \, tonnes}$. Taking into account the neutrino flavor conversion, the resulting CNO neutrino flux at Earth is $Φ_\mathrm{CNO}=6.7 ^{+1.2}_{-0.8} \times 10^8 \, \mathrm{cm^{-2} s^{-1}}$, in agreement with the high metallicity Standard Solar Models. The results described in this work reinforce the role of the event directional information in large-scale liquid scintillator detectors and open up new avenues for the next-generation liquid scintillator or hybrid neutrino experiments.

hep-ex

Borexino's search for low-energy neutrinos associated with gravitational wave events from GWTC-3 database

The search for neutrino events in correlation with gravitational wave (GW) events for three observing runs (O1, O2 and O3) from 09/2015 to 03/2020 has been performed using the Borexino data-set of the same period. We have searched for signals of neutrino-electron scattering with visible energies above 250 keV within a time window of 1000 s centered at the detection moment of a particular GW event. The search was done with three visible energy thresholds of 0.25, 0.8 and 3.0 MeV.Two types of incoming neutrino spectra were considered: the mono-energetic line and the spectrum expected from supernovae. The same spectra were considered for electron antineutrinos detected through inverse beta-decay (IBD) reaction. GW candidates originated by merging binaries of black holes (BHBH), neutron stars (NSNS) and neutron star and black hole (NSBH) were analysed separately. Additionally, the subset of most intensive BHBH mergers at closer distances and with larger radiative mass than the rest was considered. In total, follow-ups of 74 out of 93 gravitational waves reported in the GWTC-3 catalog were analyzed and no statistically significant excess over the background was observed. As a result, the strongest upper limits on GW-associated neutrino and antineutrino fluences for all flavors (ν_e, ν_μ, ν_τ) have been obtained in the (0.5 - 5.0) MeV neutrino energy range.

astro-ph.HE

Observation of a nuclear recoil peak at the 100 eV scale induced by neutron capture

Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact moderator. The measured spectrum is found in agreement with simulations and the expected peak structure from the single-$γ$ de-excitation of $^{183}$W is identified with 3 $σ$ significance. This result demonstrates a new method for precise, in-situ, and non-intrusive calibration of low-threshold experiments.

nucl-ex

Characterization of the TruSense S310 Laser Range System for Contact-less Measurement of Liquid Levels in Large-Volume Neutrino Detectors

Neutrino experiments often use large volumes of water, organic scintillators or noble liquids as active detection material. Due to the large hydrostatic and buoyancy forces involved, precise knowledge of the liquid levels inside the detector tank are mandatory. Here we present the main characteristics of the TruSense S310 Laser Range System. Level measurements can be performed without direct contact to the liquid and through a gas-proof acrylic window, thus preserving the strict radiopurity and chemical requirements of the target liquid. We report the results of a suit of laboratory experiments for short-term precision tests ($\pm$5\,mm) and long-term stability studies. Moreover, we demonstrate that the infrared laser can be used while standard bi-alkali PMTs are operational. We discuss the mechanical layout and integration of the system in the OSIRIS pre-detector that will monitor the radiopurity of the liquid scintillator for the large-volume neutrino experiment JUNO.

physics.ins-det

Exploring coherent elastic neutrino-nucleus scattering of reactor neutrinos with the NUCLEUS experiment

The NUCLEUS experiment aims to perform a high-precision measurement of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) at the EdF Chooz B nuclear power plant in France. CEvNS is a unique process to study neutrino properties and to search for physics beyond the Standard Model. The study of CEvNS is also important for light Dark-Matter searches. It could be a possible irreducible background for high-sensitivity Dark-Matter searches. NUCLEUS is an experiment under construction based on ultra-low threshold (20 eVnr) cryogenic calorimeters, operated at tens-of-mK temperatures.

physics.ins-det