SearcharxivSearch

arXiv subjects

L. Pattavina

Publications and source records attributed to L. Pattavina.

At least 19 recordsLinked to original sources

A microwave SQUID multiplexing concept for macro-cryogenic calorimeter arrays

Massive cryogenic calorimeters read out by transition-edge sensors (TES) can reach eV-scale baseline resolution, but the single-channel dc-SQUID readout conventionally used in rare-event searches, with one amplifier chain and several wires per detector, limits practical arrays to a few tens of channels. We propose to apply microwave SQUID multiplexing ($\mu$MUX), developed for fast X-ray and neutrino-mass microcalorimeters, to massive BGO (Bi$_4$Ge$_3$O$_{12}$) calorimeters operated at $\simeq 20$~mK; sapphire and TeO$_2$ absorbers are covered by the same framework. Using the established thermal and noise model for massive TES calorimeters, we derive a noise model for the multiplexed readout, including the HEMT, two-level-system and SQUID contributions, and its scaling with the multiplexing factor $N_{\rm mux}$. Since the slow thermal signals require only about a kHz of sampling per channel, the limiting requirement is not bandwidth but an input-coil sensitivity of $( 0.1$ to $1)\,\mu$A$/\Phi_0$, a factor of $10$ to $30$ beyond current $\mu$MUX devices, matched to the detector current noise of ($9$ to $10$)~pA$/\sqrt{\rm Hz}$, which is independent of the absorber mass. With a total flux noise of $\simeq$$1.2\,\mu\Phi_0/\sqrt{\rm Hz}$, the readout degrades the baseline resolution by less than $2\%$ up to $N_{\rm mux}=1000$, negligible compared with the TES-limited resolution. These results are implemented in a single-tower design: 52 BGO crystals of 100~g each and one HEMT amplifier. The tower is the unit of a multi-tower array of several kilograms aimed at CE$\nu$NS and dark matter searches.

physics.ins-det

Solar axion searches with RES-NOVA: projected sensitivity and first prototype limit

RES-NOVA is a cryogenic experiment based on PbWO4 scintillating bolometers produced from archaeological lead, originally designed to detect coherent elastic neutrino-nucleus scattering (CEvNS) from galactic core-collapse supernovae. We show that the same high-density, high-Z absorbers and sub-keV energy resolution make RES-NOVA an appealing probe of solar axions. We compute the expected signal from the Primakoff, ABC (atomic recombination and de-excitation, Bremsstrahlung, Compton), longitudinal-plasmon (LP), and 57Fe nuclear-line components of the solar axion flux, folded through the inverse-Primakoff and axioelectric detection channels in PbWO4, which probe the axion couplings to photons (g_a-gamma), electrons (g_ae), and nucleons (g_aN), respectively. We derive projected sensitivities for a 1 ton*y exposure of the RES-NOVA demonstrator in the (g_ae,g_a-gamma), (g_ae,g_aN), and (g_a-gamma,g_aN) planes. The projected reach in g_ae approaches that of XENONnT to within a factor of ~2, despite a background roughly four orders of magnitude higher, thanks to the large target mass, the high-Z enhancement of the axioelectric and inverse-Primakoff cross sections, and the sub-keV energy resolution. Because the inverse-Primakoff constraint on g_a-gamma relies on absorption rather than coherent conversion, it is independent of the axion mass, unlike bounds from magnetic helioscopes. We complement these projections with the first solar-axion exclusion limit obtained on real data with a 13 g PbWO4 prototype grown from archaeological lead, using a background-model-independent optimum-interval analysis. These results establish RES-NOVA as a promising multi-coupling probe of solar axions, with simultaneous sensitivity to g_ae, g_a-gamma and g_aN that is complementary to existing helioscope and direct-detection searches.

hep-ex

Probing large mass-splitting inelastic Dark Matter with RES-NOVA

Probing inelastic dark matter at large mass splittings requires heavy target nuclei, an extended recoil-energy range, and the high-velocity tail of the dark-matter distribution. We exploit these features with the RES-NOVA prototype detector, featuring a PbWO4 cryogenic calorimeter, produced from archaeological Pb and operated at the deep-underground laboratory of Gran Sasso of INFN (Italy), analyzing a 32.4 g day exposure over 2.5 keV - 1 MeV under both the Standard Halo Model (SHM) and a Large Magellanic Cloud (LMC)-motivated velocity distribution. We extend direct-detection constraints beyond the 330 keV reach of established technologies (e.g. Xe-based TPCs), probing splittings up to 510 (780) keV in the SHM (LMC) benchmark, while future exposures will probe new regions of the parameter space.

astro-ph.CO

Optimisation of TES design for the CRESST experiment

The CRESST experiment aims at the direct detection of sub-GeV dark matter particles via elastic scattering off nuclei in different target crystals at cryogenic temperatures. The advancement in W-TES sensors allowed the CRESST detectors to reach energy thresholds of 10 eV and lower, opening the way to the exploration of dark matter masses as low as 70 MeV/c2. This work presents optimisation studies of W-TESs aimed at further improving the signal-to-noise ratio and overall detector performance. In particular, we investigate the thickness, dimensions and material composition of phonon collectors and assess their impact on detector response. The results demonstrate a significant performance enhancement and establish new benchmarks for the sensors used within CRESST.

physics.ins-det

Search for Sterile Neutrinos with CUPID-0

Sterile neutrinos are well-motivated extensions of the Standard Model, introduced to address fundamental questions such as the origin of neutrino masses and the nature of dark matter. Exploiting the precise data reconstruction achieved by the CUPID-0 experiment, we searched for spectral distortions in the double $\beta$-decay of $^{82}$Se compatible with the emission of a sterile neutrino. The analysis relies on the construction of a detailed background model down to 200 keV, enabling an accurate characterization of the main sources of contamination. Using a Zn$^{82}$Se exposure of 9.95 kg$\cdot$yr, we explored sterile neutrino mass hypotheses between 0.5 MeV and 1.5 MeV. No evidence for a signal was observed in any scenario; therefore, we derived 90% C.I. upper limits on the active-sterile mixing probability $\sin^2\theta$, obtaining the most stringent bound, $\sin^2\theta<8\times 10^{-3}$, for a sterile neutrino mass of 0.7 MeV.

nucl-ex

ImpCresst -- A versatile simulation tool focusing on solid-state detectors at keV energies

We present ImpCresst, a Geant4-based Monte Carlo tool to simulate backgrounds from natural and cosmogenic radionuclides, and calibration signals in solid-state detectors and their response to it. It is tuned for a fast-evolving and heterogeneous detector environment with a focus on physics at the keV range. This tool was originally developed and validated by the CRESST collaboration; however, its flexibility and configurability make it suitable for other experiments with similar requirements. Key features of ImpCresst include the dynamic geometry implementation directly from CAD files, ROOT-based data persistency of the whole event topology and automatic metadata annotation for data provenance, and interfaces to various particle generators, particularly for radiogenic and cosmogenic radionuclides. It includes also a newly developed particle generator for radioactive bulk and surface contaminations which is completely independent of any user defined confinement volumes. The auxiliary tool CresstDS applies detector-specific energy and time resolution based on a user-provided data set of empirical parameterization. We discuss also how to manage an ImpCresst based workflow in an HPC environment based on Apptainer and nextflow.

physics.ins-det

Neutrino NSI in archaeological Pb

Dark matter direct detection experiments can observe solar neutrinos via coherent elastic neutrino-nucleus scattering, making it possible to test new physics in the neutrino sector. In this article, we study the sensitivity of RES-NOVA, a novel cryogenic calorimetric experiment employing PbWO$_4$ crystals grown from archaeological lead, to neutrino non-standard interactions (NSI). We perform a sensitivity study for a benchmark setup with a nominal energy threshold of 1 keV and an exposure of 1 ton$\cdot$y, both for a conservative (only heat readout) and ideal (heat and scintillation) background rejection scenario. We find that, in its nominal configuration, while not being sensitive to Standard Model solar $\nu$ interactions, RES-NOVA can reach sensitivities to NSI at the level of current global fits. With moderate or significant improvements of the threshold down to $0.5$ keV and $0.2$ keV, RES-NOVA will be able to achieve sensitivities beyond NSI global fit results, testing new areas of the parameter space in the electron and tau sectors, $\varepsilon_{ee}$, $\varepsilon_{\tau\tau}$, and $\varepsilon_{e\tau}$. A similar improvement in sensitivities is expected when instead increasing the exposure to 10 ton$\cdot$y.

hep-ph

A rapid low-background assay of $^{210}$Pb in archaeological lead

In this work, we present a fast and highly efficient method for the measurement of $^{210}$Pb in metallic archaeological lead using the commercial low-background liquid scintillation counter Wallac Quantulus 1220 installed at the University of Milano-Bicocca (Italy). By combining an optimized chemical preparation with pulse-shape analysis (PSA), the technique achieves sensitivities at the level of a few $10^2$ mBq/kg within one week of measurement, using sample masses below 1 g. The method enables the simultaneous identification of the $\beta$ decays of $^{210}$Pb and $^{210}$Bi and the $\alpha$ decay of $^{210}$Po, allowing a direct verification of secular equilibrium within the decay chain. With extended acquisition times, detection limits below 100 mBq/kg are reached after approximately 40 days. This approach provides a rapid, accessible, and reliable tool for the radiopurity screening of lead, and is well suited for quality control and R&D activities in next-generation low-background and rare-event physics experiments. Moreover, the method has the potential to be extended to other materials relevant for low-background applications.

physics.ins-det

Probing dark matter interactions with a RES-NOVA prototype cryogenic detector

We report on the operation of a 13 g PbWO$_4$ crystal, grown from archaeological Pb and operated as a cryogenic calorimeter in an underground environment. Read out with a Ge thermistor, the detector achieves a low energy threshold and, for the first time, enables the derivation of a dark matter exclusion limit using PbWO$_4$ as target material, for both spin-dependent interactions on neutrons and spin-independent interactions. Although limited in mass and not representative of the final RES-NOVA detector design, this prototype demonstrates effective control of mechanical vibrations and low-energy noise in a cryogenic system, which is a key requirement for rare-event searches. The experiment therefore provides a proof of principle for the RES-NOVA detection concept, validating the use of archaeological Pb-based PbWO$_4$ crystals, low-background operation, and robust data-analysis procedures. These results establish a solid technological and methodological foundation for future RES-NOVA detectors employing larger target masses and advanced thermal readout technologies.

physics.ins-det

End-to-End Data Analysis Methods for the CUORE Experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) experiment set the most stringent limit on the neutrinoless double-beta ($0νββ$) decay half-life of $^{130}$Te with 2 ton yr TeO$_2$ analyzed exposure. In addition to $0νββ$ decay, the CUORE detector -- a ton-scale array of nearly 1000 cryogenic calorimeters operating at $\sim$10 mK -- is capable of searching for other rare decays and interactions over a broad energy range. For our searches, we leverage the available information of each calorimeter by performing its optimization, data acquisition, and analysis independently. We describe the analysis tools and methods developed for CUORE and their application to build high-quality datasets for numerous physics searches. In particular, we describe in detail our evaluation of the energy-dependent detector response and signal efficiency used in the most recent search for $0νββ$ decay.

nucl-ex

Constraints on Lepton Number Violation with the 2 tonne$\cdot$yr CUORE Dataset

Matter-antimatter asymmetry underlines the incompleteness of the current understanding of particle physics. Neutrinoless double-beta decay ($0νββ$) may help explain this asymmetry, while unveiling the Majorana nature of the neutrino. The CUORE experiment searches for $0νββ$ of $^{130}$Te using a tonne-scale cryogenic calorimeter operated at milli-kelvin temperatures. We report no evidence of $0νββ$ and place a lower limit on the half-life of $T_{1/2} >3.5 \times$ 10$^{25}$~years (90\% C.I.) with over 2~tonne$\cdot$year TeO$_2$ exposure. The tools and techniques developed for this result and the 5 year stable operation of nearly 1000 detectors demonstrate crucial infrastructure for a future-generation experiment capable of searching for $0νββ$ across multiple isotopes.

nucl-ex

Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source

Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677\,eV to 6.5\,keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 gram CaWO$_4$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).

physics.ins-det

Reconstruction of cosmic-ray muon events with CUORE

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta ($0\nu\beta\beta$) decay, leveraging the segmentation of the detector. Due to the slow time response of the detector, time-of-flight estimation is not feasible. Therefore, the track reconstruction is performed using a multi-objective optimization algorithm that relies on geometrical information from the detector as a whole. We measure the integral flux of cosmic-ray muons underground at the {\it Laboratori Nazionali del Gran Sasso}, and find our value to be in good agreement with other experiments that have performed a similar measurement. To our knowledge, this work represents the first demonstration of 3D particle tracking and reconstruction of through-going muons with per-event angular determination in a millikelvin cryogenic detector array. The analysis performed for this work will be critical for validating the muon-related background in CUPID, a next-generation $0\nu\beta\beta$ experiment, and for follow-up studies on detector response and on delayed products induced by cosmic-ray muons.

physics.ins-det

Description of CRESST-III lithium aluminate data

Two detector modules with lithium aluminate targets were operated in the CRESST underground setup between February and June 2021. The data collected in this period was used to set the currently strongest cross-section upper limits on the spin-dependent interaction of dark matter (DM) with protons and neutrons for the mass region between 0.25 and 1.5 GeV/c$^2$. The data are available online. In this document, we describe how the data set should be used to reproduce our dark matter results.

hep-ex

Description of CRESST-II and CRESST-III pulse shape data

A set of data from 68 cryogenic detectors operated in the CRESST dark matter search experiment between 2013 and 2019 was collected and labeled to train binary classifiers for data cleaning. Here, we describe the data set and how the trained models can be applied to new data. The data and models are available online.

physics.ins-det

Observation of a low energy nuclear recoil peak in the neutron calibration data of an Al$_{2}$O$_{3}$ crystal in CRESST-III

The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of $\mathcal{O}$(10)$\,$eV for nuclear recoils. For a reliable calibration in this energy regime a method has been proposed, providing mono-energetic nuclear recoils at low energies $\sim\,$100$\,$eV$\,$-$\,$1$\,$keV. In this work we report on the observation of a peak at (1113.6$^{+6.5}_{-6.5}$)$\,$eV in the data of an Al$_{2}$O$_{3}$ crystal in CRESST-III, which was irradiated with neutrons from an AmBe calibration source. We attribute this mono-energetic peak to the radiative capture of thermal neutrons on $^{27}$Al and the subsequent de-excitation via single $γ$-emission. We compare the measured results with the outcome of Geant4 simulations and investigate the possibility to make use of this effect for the energy calibration of Al$_{2}$O$_{3}$ detectors at low energies. We further investigate the possibility of a shift in the expected energy scale of this effect caused by the creation of defects in the target crystal.

physics.ins-det

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the CUORE experiment, based on more than 2 tonne yr of data collected over 5 years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data taking conditions. We achieve an average baseline resolution of 2.54 $\pm$ 0.14 keV FWHM and 1.18 $\pm$ 0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06 $\pm$ 0.05 counts/(keV kg days) and 16 $\pm$ 2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 26 $\pm$ 4 \% and 50 $\pm$ 2 \% at 3 keV and 10 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that tonne-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

hep-ex

The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ($0\nu\beta\beta$) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here we report the first detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for $0\nu\beta\beta$ decay with mK-scale calorimeters and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE's energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to $0\nu\beta\beta$ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.

physics.ins-det