The development of gaseous detectors with solid photocathodes for low temperature

There are several applications and fundamental research areas which require the detection of VUV light at cryogenic temperatures. For these applications we have developed and successfully tested special designs of gaseous detectors with solid photocathodes able to operate at low temperatures: sealed gaseous detectors with MgF2 windows and windowless detectors. We have experimentally demonstrated, that both primary and secondary (due to the avalanche multiplication inside liquids) scintillation lights could be recorded by photosensitive gaseous detectors. The results of this work may allow one to significantly improve the operation of some noble liquid gas TPCs.

physics.ins-det↗

Beyond the RICH: Innovative Photosensitive Gaseous Detectors for new Fields of Applications

We have developed and successfully used several innovative designs of detectors with solid photocathodes. The main advantage of these detectors is that rather high gains (>10E4) can be achieved in a single multiplication step. This is possible by, for instance, exploiting the secondary electron multiplication and limiting the energy of the steamers by distributed resistivity. The single step approach also allows a very good position resolution to be achieved in some devices: 50 micron on line without applying any treatment method (like center of gravity). The main focus of our report is new fields of applications for these detectors and the optimization of their designs for such purposes.

physics.ins-det↗

Evaluation of various planar gaseous detectors with CsI photocathodes for the detection of primary scintillation light from noble gases

Noble gases and liquids are excellent scintillators and this opens a unique opportunity to directly detect the primary scintillation light produced in these media by photons or particles. This signal can be used for several purposes, for example as a start signal for TPCs or for particles identification. Usually photomultipliers (PMs) are used for the detection of the scintillation light. In our previous work we have demonstrated that costly PMs could be replaced by gaseous detectors with CsI photocathodes . Such detectors have the same quantum efficiency as the best PMs but at the same time are cheap, simple and have high position and time resolutions. The aim of this work is to evaluate various planar type gaseous detectors with CsI photocahodes in order to choose the best one for the detection of the primary scintillation light from noble gases and liquids.

physics.ins-det↗

Detection of the primary scintillation light from dense Ar, Kr and Xe with novel photosensitive gaseous detectors

The detection of primary scintillation light in combination with the charge or secondary scintillation signals is an efficient technique to determine the events t=0 as well as particle / photon separation in large mass TPC detectors filled with noble gases and/or condensed noble gases. The aim of this work is to demonstrate that costly photo-multipliers could be replaced by cheap novel photosensitive gaseous detectors: wire counters, GEMs or glass capillary tubes coupled with CsI photocathodes. We have performed systematic measurements with Ar, Kr and Xe gas at pressures in the range of 1-50 atm as well as some preliminary measurements with liquid Xe and liquid Ar. With the gaseous detectors we succeeded in detecting scintillation light produced by 22 keV X-rays with an efficiency of close to 100%. We also detected the scintillation light produced by bs (5 keV deposit energy) with an efficiency close to 25%. Successful detection of scintillation from 22 keV gammas open new experimental possibilities not only for nTOF and ICARUS experiments, but also in others, like WIMPs search through nuclear recoil emission.

physics.ins-det↗

Measurement of neutrino oscillations by means of a high density detector on the atmospheric neutrino beam

A high-density calorimeter, consisting of magnetized iron planes interleaved by RPCs, as tracking and timing devices, is a good candidate for a next generation experiment on atmospheric neutrinos. With 34 kt of mass and in four years of data taking, this experiment will be sensitive to $ν_μ\to ν_x$ oscillation with $Δm^2 > 6 \times 10^{-5}$ and mixing near to maximal and fully cover the region of oscillation parameters suggested by Super-Kamiokande results. Moreover, the experimental method will enable to measure the oscillation parameters from the modulation of the L/E spectrum ($ν_μ$ disappearance). For $Δm^2 > 3 \times 10^{-3}$ eV$^2$, this experiment can also establish whether the oscillation occurs into a tau or a sterile neutrino, by looking for an excess of muon-less events at high energies produced by upward-going tau neutrinos ($ν_τ$ appearance).

hep-ex↗

Measurement of Atmospheric Neutrino Oscillations with a High-Density Detector

We propose an experiment to test the hypothesis that the reported anomaly on atmospheric neutrino fluxes is due to nu_mu <-> nu_x oscillations. It will rely both on a disappearance technique, exploiting the method of the dependence of the event rate on L/E, which was recently shown to be effective for detection of neutrino oscillation and measurement of the oscillation parameters, and on an appearance technique, looking for an excess of muon-less events at high energy produced by upward-going tau neutrinos. The detector will consist of iron planes interleaved by limited streamer tubes. The total mass will be about 30 kt. The possibility of recuperating most of the instrumentation from existing detectors allows to avoid R&D phases and to reduce construction time. In four years of data taking, this experiment will be sensitive to oscillations nu_mu <-> nu_x with Delta m^2 > 10^-4 eV^2 and a mixing near to maximal, and answer the question whether nu_x is a sterile or a tau neutrino.

hep-ph↗

A Test of $\numunux$ Oscillations and determination of the $Δm^2$ parameter of Atmospheric Neutrinos using the $L/E$ method

We point out that the measurement of the $L/E$ distribution of atmospheric neutrino events with sufficient resolution in order to observe the characteristic modulations of neutrino oscillations would provide a unique way to test the $\numunux$ oscillations nature of the atmospheric neutrino anomaly in the parameter range $5\times 10^{-4} < Δm^2 < 2\times 10^{-3}\rm\ eV^2$. With an integrated exposure of a few tens of kiloton-year, this method can cover the lower part of the $Δm^2$ region of the currently allowed atmospheric neutrino solution and is therefore complementary to the one explorable with planned long-baseline neutrino beam experiments. We stress that experimentally this method relies on the ability to measure high energy muons ($E_μ>5\rm GeV$). A large magnetized calorimeter of several kilotons would be ideally suited for this measurement. The existing LEP detectors augmented with atmospheric neutrino triggers could also be used to perform such a study.