SearcharxivSearch

arXiv subjects

L. Persanti

Publications and source records attributed to L. Persanti.

2 recordsLinked to original sources

Measurement and analysis of the $^{246}$Cm and $^{248}$Cm neutron capture cross-sections at the EAR2 of the n TOF facility

The $^{246}$Cm(n,$\gamma$) and $^{248}$Cm(n,$\gamma$) cross-sections have been measured at the Experimental Area 2 (EAR2) of the n_TOF facility at CERN with three C$_6$D$_6$ detectors. This measurement is part of a collective effort to improve the capture cross-section data for Minor Actinides (MAs), which are required to estimate the production and transmutation rates of these isotopes in light water reactors and innovative reactor systems. In particular, the neutron capture in $^{246}$Cm and $^{248}$Cm open the path for the formation of other Cm isotopes and heavier elements such as Bk and Cf and the knowledge of (n,$\gamma$) cross-sections of these Cm isotopes plays an important role in the transport, transmutation and storage of the spent nuclear fuel. The reactions $^{246}$Cm(n,$\gamma$) and $^{248}$Cm(n,$\gamma$) have been the two first capture measurements analyzed at n_TOF EAR2. Until this experiment and two recent measurements performed at J-PARC, there was only one set of data of the capture cross-sections of $^{246}$Cm and $^{248}$Cm, that was obtained in 1969 in an underground nuclear explosion experiment. In the measurement at n_TOF a total of 13 resonances of $^{246}$Cm between 4 and 400 eV and 5 of $^{248}$Cm between 7 and 100 eV have been identified and fitted. The radiative kernels obtained for $^{246}$Cm are compatible with JENDL-5, but some of them are not with JENDL-4, which has been adopted by JEFF-3.3 and ENDF/B-VIII.0. The radiative kernels obtained for the first three $^{248}$Cm resonances are compatible with JENDL-5, however, the other two are not compatible with any other evaluation and are 20% and 60% larger than JENDL-5.

nucl-ex

Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques

i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in ($n,\gamma$) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background rejection. To this aim both $^{197}$Au($n,\gamma$) and $^{56}$Fe($n, \gamma$) reactions were measured at CERN n\_TOF using an i-TED demonstrator based on only three position-sensitive detectors. Two \cds detectors were also used to benchmark the performance of i-TED. The i-TED prototype built for this study shows a factor of $\sim$3 higher detection sensitivity than state-of-the-art \cds detectors in the $\sim$10~keV neutron energy range of astrophysical interest. This paper explores also the perspectives of further enhancement in performance attainable with the final i-TED array consisting of twenty position-sensitive detectors and new analysis methodologies based on Machine-Learning techniques.

physics.ins-det