SearcharxivSearch

arXiv subjects

L. Piron

Publications and source records attributed to L. Piron.

2 recordsLinked to original sources

Improved n=1 Empirical Error Field Penetration Threshold Scaling with Ohmic and L-Mode Conventional Tokamak Plasma Discharges

This paper presents an updated n=1 error field penetration threshold scaling, which increases fit quality compared to previous error field scaling laws, is produced from an expanded database, and exhibits reduced uncertainty in projections to future conventional tokamaks. It improves confidence in tokamak engineering tolerances, which are a significant driver of cost and time constraints on device construction. We add J-TEXT data, new JET data, and create the scaling using only conventional tokamak Ohmic and L-mode experiments. Since H-mode plasmas are more resilient to error field penetration, this scaling predicts what is likely the most dangerous regime of error field penetration for new tokamak designs. These decisions improve confidence in the error field penetration threshold scaling and its application in the construction and design decisions of any future conventional tokamak or FPP.

physics.plasm-ph

An active feedback recovery technique from disruption events induced by m=2 n=1 tearing modes in ohmically heated tokamak plasmas

We present experimental results of magnetic feedback control on the m=2, n=1 tearing mode in RFX-mod operated as a circular ohmically heated tokamak. The feedback suppression of the non-resonant m=2, n=1 Resistive Wall Mode (RWM) in q(a)<2 plasmas is a well-established result of RFX-mod. The control of the tearing counterpart, which develops in q(a)>2 equilibrium, is instead a more difficult issue. In fact, the disruption induced by a growing amplitude m=2, n=1 tearing mode can be prevented by feedback only when the resonant surface q=2 is close to the plasma edge, namely 2<q(a)<2.5, and the electron density does not exceed approximately half of the Greenwald limit. A combined technique of tearing mode and q(a) control has been therefore developed to recover the discharge from the most critical conditions: the potentially disruptive tearing mode is converted into the relatively benign RWM by suddenly decreasing q(a) below 2. The experiments demonstrate the concept with 100% of successful cases. The q(a) control has been performed through the plasma current, given the capability of the toroidal loop-voltage power supply of RFX-mod. We also propose a path for controlling q(a) by acting on the plasma shape, which could be applied to medium size elongated tokamaks.

physics.plasm-ph