SearcharxivSearch

arXiv subjects

L. R. Vale

Publications and source records attributed to L. R. Vale.

18 recordsLinked to original sources

Phenomenological Modeling of the $^{163}$Ho Calorimetric Electron Capture Spectrum from the HOLMES Experiment

We present a comprehensive phenomenological analysis of the calorimetric electron capture (EC) decay spectrum of $^{163}$Ho as measured by the HOLMES experiment. Using high-statistics data, we unfold the instrumental energy resolution from the measured spectrum and model it as a sum of Breit-Wigner resonances and shake-off continua, providing a complete set of parameters for each component. Our approach enables the identification and tentative interpretation of all observed spectral features, including weak and overlapping structures, in terms of atomic de-excitation processes. We compare our phenomenological model with recent ab initio theoretical calculations, finding good agreement for both the main peaks and the spectral tails, despite the limitations of current theoretical and experimental precision. The model delivers an accurate description of the endpoint region, which is crucial for neutrino mass determination, and allows for a realistic treatment of backgrounds such as pile-up and tails of low-energy components. Furthermore, our decomposition facilitates the generation of Monte Carlo toy spectra for sensitivity studies and provides a framework for investigating systematic uncertainties related to solid-state and detector effects. This work establishes a robust foundation for future calorimetric neutrino mass experiments employing $^{163}$Ho, supporting both data analysis and experimental design.

nucl-ex

Most stringent bound on electron neutrino mass obtained with a scalable low temperature microcalorimeter array

The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the Standard Model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. In this Letter, we present the most stringent upper bound on the effective electron neutrino mass ever obtained with a calorimetric measurement of the electron capture decay of $^{163}$Ho. The HOLMES experiment employs an array of ion-implanted transition-edge sensor (TES) microcalorimeters, achieving an average energy resolution of 6 eV FWHM with a scalable, multiplexed readout technique. With a total of $7\times10^7$ decay events recorded over two months and a Bayesian statistical analysis, we derive an upper limit of $m_{\beta}<27$ eV/c$^2$ at 90% credibility. These results validate the feasibility of $^{163}$Ho calorimetry for next-generation neutrino mass experiments and demonstrate the potential of a scalable TES-based microcalorimetric technique to push the sensitivity of direct neutrino mass measurements beyond the current state of the art.

hep-ex

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (umux). This umux is designed to multiplex signals from arrays of low temperature detectors such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from $1.6$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA off, to $0.77$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA on. When statically biasing the umux to the maximally flux-sensitive point, the flux noise drops from $0.45$ $μΦ_0/\sqrt{\mathrm{Hz}}$ to $0.2$ $μΦ_0/\sqrt{\mathrm{Hz}}$. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the umux and detecting background radiation. The combination of umux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

astro-ph.IM

A Microwave SQUID Multiplexer Optimized for Bolometric Applications

A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/$\sqrt{\textrm{Hz}}$, evaluated at 2 Hz, with a 1/f knee $\leq$ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is $\leq$ 0.3%.

astro-ph.IM

Progress in the development of TES microcalorimeter detectors suitable for neutrino mass measurement

The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiNx membrane with gold absorbers. Considering the large number of pixels and an event rate of about 300 Hz/pixel, a large multiplexing factor and a large bandwidth are needed. To fulfill this requirement, HOLMES will exploit recent advances in microwave multiplexing. In this contribution, we present the status of the activities in development, the performances of the developed microwave-multiplexed readout system, and the results obtained with the detectors specifically designed for HOLMES in terms of noise, time, and energy resolutions

physics.ins-det

Resonant soft x-ray scattering from stripe-ordered La$_{2-x}$Ba$_x$CuO$_4$ detected by a transition edge sensor array detector

Resonant soft x-ray scattering (RSXS) is a leading probe of valence band order in materials best known for detecting charge density wave order in the copper-oxide superconductors. One of the biggest limitations on the RSXS technique is the presence of a severe fluorescence background which, like the RSXS cross section itself, is enhanced under resonant conditions. This background prevents the study of weak signals such as diffuse scattering from glassy or fluctuating order that is spread widely over momentum space. Recent advances in superconducting transition edge sensor (TES) detectors have led to major improvements in energy resolution and detection efficiency in the soft x-ray range. Here, we perform a RSXS study of stripe-ordered La$_{2-x}$Ba$_x$CuO$_4$ at the Cu $L_{3/2}$ edge (932.2 eV) using a TES detector with 1.5 eV resolution, to evaluate its utility for mitigating the fluorescence background problem. We find that, for suitable degree of detuning from the resonance, the TES rejects the fluorescence background, leading to a 5 to 10 times improvement in the statistical quality of the data compared to an equivalent, energy-integrated measurement. We conclude that a TES presents a promising approach to reducing background in RSXS studies and may lead to new discoveries in materials exhibiting valence band order that is fluctuating or glassy.

cond-mat.str-el

Performance of Al-Mn Transition-Edge Sensor Bolometers in SPT-3G

SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150~mm-diameter detector wafers, containing a total of 16,000 transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of these detector wafers was replaced by a new wafer fabricated with Al-Mn TESs instead of the Ti/Au design originally deployed for SPT-3G. We present the results of in-lab characterization and on-sky performance of this Al-Mn wafer, including electrical and thermal properties, optical efficiency measurements, and noise-equivalent temperature. In addition, we discuss and account for several calibration-related systematic errors that affect measurements made using frequency-domain multiplexing readout electronics.

astro-ph.IM

On-sky performance of the SPT-3G frequency-domain multiplexed readout

Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme enables the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x fMux system to operate its large-format camera of $\sim$16,000 TES bolometers. We present here the successful implementation and performance of the SPT-3G readout as measured on-sky. Characterization of the noise reveals a median pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency noise in the readout will not limit SPT-3G's measurements of sky power on large angular scales. Measurements also show that the median readout white noise level in each of the SPT-3G observing bands is below the expectation for photon noise, demonstrating that SPT-3G is operating in the photon-noise-dominated regime.

astro-ph.IM

Design and Bolometer Characterization of the SPT-3G First-year Focal Plane

During the austral summer of 2016-17, the third-generation camera, SPT-3G, was installed on the South Pole Telescope, increasing the detector count in the focal plane by an order of magnitude relative to the previous generation. Designed to map the polarization of the cosmic microwave background, SPT-3G contains ten 6-in-hexagonal modules of detectors, each with 269 trichroic and dual-polarization pixels, read out using 68x frequency-domain multiplexing. Here we discuss design, assembly, and layout of the modules, as well as early performance characterization of the first-year array, including yield and detector properties.

astro-ph.IM

Year two instrument status of the SPT-3G cosmic microwave background receiver

The South Pole Telescope (SPT) is a millimeter-wavelength telescope designed for high-precision measurements of the cosmic microwave background (CMB). The SPT measures both the temperature and polarization of the CMB with a large aperture, resulting in high resolution maps sensitive to signals across a wide range of angular scales on the sky. With these data, the SPT has the potential to make a broad range of cosmological measurements. These include constraining the effect of massive neutrinos on large-scale structure formation as well as cleaning galactic and cosmological foregrounds from CMB polarization data in future searches for inflationary gravitational waves. The SPT began observing in January 2017 with a new receiver (SPT-3G) containing $\sim$16,000 polarization-sensitive transition-edge sensor bolometers. Several key technology developments have enabled this large-format focal plane, including advances in detectors, readout electronics, and large millimeter-wavelength optics. We discuss the implementation of these technologies in the SPT-3G receiver as well as the challenges they presented. In late 2017 the implementations of all three of these technologies were modified to optimize total performance. Here, we present the current instrument status of the SPT-3G receiver.

astro-ph.IM

Microwave SQUID Multiplexer demonstration for Cosmic Microwave Background Imagers

Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($μ$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $μ$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density exhibits a white spectrum at low frequencies ($\sim$~100~mHz), which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the $μ$MUX as a viable readout technique for future CMB imaging instruments.

astro-ph.IM

Generating and verifying entangled itinerant microwave fields with efficient and independent measurements

By combining a squeezed propagating microwave field and an unsqueezed vacuum field on a hybrid (microwave beam-splitter), we generate entanglement between the two output modes. We verify that we have generated entangled states by making independent and efficient single-quadrature measurements of the two output modes. We observe the entanglement witness $E_\mathrm{W}=-0.263^{+0.001}_{-0.036}$ and the negativity $N=0.0824^{+0.01}_{-0.0004}$ with measurement efficiencies at least $26\pm{0.1}\%$ and $41\pm{0.2}\%$ for channel~1 and 2 respectively. These measurements show that the output two-mode state violates the separability criterion and therefore demonstrate entanglement. This shared entanglement between propagating microwaves provides an important resource for building quantum networks with superconducting microwave systems.

quant-ph

Advanced code-division multiplexers for superconducting detector arrays

Multiplexers based on the modulation of superconducting quantum interference devices are now regularly used in multi-kilopixel arrays of superconducting detectors for astrophysics, cosmology, and materials analysis. Over the next decade, much larger arrays will be needed. These larger arrays require new modulation techniques and compact multiplexer elements that fit within each pixel. We present a new in-focal-plane code-division multiplexer that provides multiplexing elements with the required scalability. This code-division multiplexer uses compact lithographic modulation elements that simultaneously multiplex both signal outputs and superconducting transition-edge sensor (TES) detector bias voltages. It eliminates the shunt resistor used to voltage bias TES detectors, greatly reduces power dissipation, allows different dc bias voltages for each TES, and makes all elements sufficiently compact to fit inside the detector pixel area. These in-focal-plane code-division multiplexers can be combined with multi-gigahertz readout based on superconducting microresonators to scale to even larger arrays.

astro-ph.IM

Quantum state tomography of an itinerant squeezed microwave field

We perform state tomography of an itinerant squeezed state of the microwave field prepared by a Josephson parametric amplifier (JPA). We use a second JPA as a pre-amplifier to improve the quantum efficiency of the field quadrature measurement (QM) from 2% to 36 +/- 4%. Without correcting for the detection inefficiency we observe a minimum quadrature variance which is 69 +/- 8% of the variance of the vacuum. We reconstruct the state's density matrix by a maximum likelihood method and infer that the squeezed state has a minimum variance less than 40% of the vacuum, with uncertainty mostly caused by calibration systematics.

quant-ph

Design and Testing of Superconducting Microwave Passive Components for Quantum Information Processing

We report on the design, fabrication and testing of two superconducting passive microwave components, a quadrature hybrid and a 20 dB directional coupler. These components are designed to be integrated with superconducting qubits or Josephson parametric amplifiers and used in quantum information processing applications. For the coupler, we measure return loss and isolation > 20 dB, and insertion loss < 0.3 dB in a 2 GHz band around 6 GHz. For the hybrid performance, we measure isolation > 20 dB and insertion loss < 0.3 dB in a 10% band around 6.5 GHz. These values are within the design specifications of our application; however, we find a 7% difference between the designed and measured center frequency for the hybrid.

quant-ph

Strongly quadrature-dependent noise in superconducting micro-resonators measured at the vacuum-noise limit

We measure frequency- and dissipation-quadrature noise in superconducting lithographed microwave resonators with sensitivity near the vacuum noise level using a Josephson parametric amplifier. At an excitation power of 100~nW, these resonators show significant frequency noise caused by two-level systems. No excess dissipation-quadrature noise (above the vacuum noise) is observed to our measurement sensitivity. These measurements demonstrate that the excess dissipation-quadrature noise is negligible compared to vacuum fluctuations, at typical readout powers used in micro-resonator applications. Our results have important implications for resonant readout of various devices such as detectors, qubits and nano-mechanical oscillators.

cond-mat.supr-con

Bandwidth and dynamic range of a widely tunable Josephson parametric amplifier

The ability to manipulate quantum information encoded in microwave fields has led to a renewed interest in Josephson parametric amplifiers (JPAs). For these applications the ability of JPAs to amplify signals with the least amount of added noise is critical. Unfortunately JPAs are typically narrow band amplifiers with small dynamic range. It is therefore important to understand the bandwidth and dynamic range of any particular JPA in order to determine if it is appropriate for these applications. We recently introduced a new kind of JPA. Although it is still narrow band, the amplified band can be tuned over a full octave. We have shown that it has good noise performance and can squeeze the vacuum noise by 10 dB. Here we characterize other important parameters of this amplifier, specifically the signal-bandwidth, dynamic range and saturation power.

cond-mat.mes-hall

Amplification and squeezing of quantum noise with a tunable Josephson metamaterial

It has recently become possible to encode the quantum state of superconducting qubits and the position of nanomechanical oscillators into the states of microwave fields. However, to make an ideal measurement of the state of a qubit, or to detect the position of a mechanical oscillator with quantum-limited sensitivity requires an amplifier that adds no noise. If an amplifier adds less than half a quantum of noise, it can also squeeze the quantum noise of the electromagnetic vacuum. Highly squeezed states of the vacuum serve as an important quantum information resource. They can be used to generate entanglement or to realize back-action-evading measurements of position. Here we introduce a general purpose parametric device, which operates in a frequency band between 4 and 8 GHz. It is a subquantum-limited microwave amplifier, it amplifies quantum noise above the added noise of commercial amplifiers, and it squeezes quantum fluctuations by 10 dB.

cond-mat.mes-hall