SearcharxivSearch

arXiv subjects

L. Robinson

Publications and source records attributed to L. Robinson.

13 recordsLinked to original sources

Calibrating Mid-Infrared Emission Features As Diagnostics of Star Formation in Infrared-Luminous Galaxies via Radiative Transfer Modeling

Luminous infrared galaxies are key sites of obscured stellar mass assembly at z > 0.5. Their star formation rates (SFRs) are often estimated using the luminosities of the 6.2 micron and 11.2 micron polycyclic aromatic hydrocarbon (PAH) features, or those of the [Ne II] and [Ne III] fine-structure lines, as they are minimally affected by obscuration. It is uncertain whether the calibration of these features as SFR tracers depends on the starburst bolometric luminosity or the level of Active Galactic Nucleus (AGN) activity. We here investigate the relationship between the luminosities of PAH and Neon lines with star formation rate for highly luminous objects using radiative transfer modeling and archival observations of 42 local Ultraluminous (>= 10^12 L_sun) Infrared Galaxies (ULIRGs). We find that PAH and [Ne II] features arise mainly in star-forming regions, with small contributions from the AGN or host, but that the [Ne III] line has a mixed contribution from both star formation and AGN activity. We present relations between L_PAH and L_NeII, and both starburst luminosity and SFR. We find relations for lower luminosity (L_IR ~= 10^10-10^12 L_sun) systems underestimate the SFRs in local ULIRGs by up to ~1 dex. The 6.2 micron and 11.2 micron PAH features, and the [Ne II] line, are thus good tracers of SFR in ULIRGs. We do not find that a more luminous AGN affects the relationship between SFR and PAH or Neon luminosity, but that it can make PAH emission harder to discern. Our results and derived relations are relevant to studies of star-forming and composite galaxies at z < 3 with the James Webb Space Telescope.

astro-ph.GA

Multitube monitors: a new-generation of neutron beam monitors

With the renewal of many neutron science instruments and the commissioning of new neutron facilities, there is a rising demand for improved neutron beam monitoring systems with reduced beam perturbations and higher counting rate capability. Fission chambers are the most popular beam monitors; however, their use on some instruments may be prevented by the background generated by fast neutrons emitted during neutron captures in 235U and by neutrons scattered in the material of the fission chamber. Multitube detectors, on the other hand, offer a good alternative with minimum beam perturbations. The purpose of this paper is to report and analyse the results of the measurements performed with several Multitubes used for beam monitoring. We show that the transparency of Multitube beam monitors is 97.6 +/-0.4 %, and that their detection efficiency is uniform, with a deviation from the mean value < 0.7%. A counting rate reduction of 10% due to pile-up effects is measured at a rate of 550 kHz. In addition to neutron beam intensity monitoring, the Multitube can be configured for 1-dimensional or 2-dimensional localisation. We present the preliminary results of these additional functionalities.

physics.ins-det

uRANIA-V: an innovative solution for neutron detection in homeland security

Detection of neutrons is becoming of the utmost importance, especially in the studies of radioactive waste and in homeland security applications. The crisis of 3He availability has required the development of innovative techniques. One solution is to develop light gas detectors for neutron counting to be used as portals for ports and airports. The neutron is converted on the Boron-coated cathode, releasing a charged particle, whose passage can be identified by the gas detector. While several technologies have been deployed in the past, the project {\mu}RANIA-V ( {\mu}Rwell Advanced Neutron Identification Apparatus) aims to detect thermal neutrons by means of the {\mu}Rwell technology, an innovative gas detector. The goal is to produce tiles to operate as portals in homeland security or for radioactive waste management. The technological transfer towards the industry has started, thus the production can be cost-effective also owing to a construction process relatively easier compared to similar apparatus. By reading directly the signals from the amplification stage, the neutrons can be counted with simplified electronics further reducing the total cost. In this paper, the project will be described, with details on the {\mu}Rwell technology and on the neutron counting, on the test beam performed, and on the future plans.

physics.ins-det

Statistical position reconstruction for RPC-based thermal neutron detectors

Multilayer position-sensitive 10B-RPC thermal neutron detectors offer an attractive combination of sub-millimeter spatial resolution and high (>50%) detection efficiency. Here we describe a new position reconstruction method based on a statistical approach. Using experimental data, we compare the performance of this method with that of the centroid reconstruction. Both methods result in a similar image linearity/uniformity and spatial resolution. However, the statistical method allows to improve the image quality at the detector periphery, offers more flexible event filtering and allows to develop automatic quality monitoring procedures for early detection of situations when a change in the detector operation conditions starts to affect reconstruction quality.

physics.ins-det

Towards high-rate RPC-based thermal neutron detectors using low-resistivity electrodes

We present experimental results on the counting rate measurements for several single-gap $^{10}$B lined resistive plate chambers ($^{10}$B-RPCs) with anodes made from standard float glass, low resistivity glass and ceramic. The measurements were performed at the V17 monochromatic neutron beamline (3.35 \.A) at the Helmholtz-Zentrum Berlin. For the $^{10}$B-RPCs with 0.28 mm thick float glass a maximum counting rate density of about $8\times 10^{3}$ $Hz/cm^{2}$ was obtained. In the case of low resistivity glass and ceramic, the counting rate density did not deviate from linear dependence on the neutron flux up to the maximum flux available at this beamline and exceeded a value of $3\times 10^{4}$ $Hz/cm^{2}$.

physics.ins-det

Time- and energy-resolved effects in the boron-10 based Multi-Grid and helium-3 based thermal neutron detectors

The boron-10 based Multi-Grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few $\mu$eV, while comparing it to the performance of a typical helium-3 tube. Furthermore, it is to characterize differences between the detector technologies in terms of internal scattering, as well as the time reconstruction of ~ $\mu$s short neutron pulses. The data were taken at the Helmholtz Zentrum Berlin, where the Multi-Grid detector and a helium-3 tube were installed at the ESS test beamline, V20. Using a Fermi-chopper, the neutron beam of the reactor was chopped into a few tens of $\mu$s wide pulses before reaching the detector, located a few tens of cm downstream. The data of the measurements show an agreement between the derived and calculated neutron detection efficiency curve. The data also provide fine details on the effect of internal scattering, and how it can be reduced. For the first time, the chopper resolution was comparable to the timing resolution of the Multi-Grid detector. This allowed a detailed study of time- and energy resolved effects, as well as a comparison with a typical helium-3 tube.

physics.ins-det

u-RANIA: a neutron detector based on \mu -RWELL technology

In the framework of the ATTRACT-uRANIA project, funded by the European Community, we are developing an innovative neutron imaging detector based on micro-Resistive WELL ($\mu$ -RWELL) technology. The $\mu$ -RWELL, based on the resistive detector concept, ensuring an efficient spark quenching mechanism, is a highly reliable device. It is composed by two main elements: a readout-PCB and a cathode. The amplification stage for this device is embedded in the readout board through a resistive layer realized by means of an industrial process with DLC (Diamond-Like Carbon). A thin layer of B$_4$C on the copper surface of the cathode allows the thermal neutrons detection through the release of $^7$Li and $\alpha$ particles in the active volume. This technology has been developed to be an efficient and convenient alternative to the $^3$He shortage. The goal of the project is to prove the feasibility of such a novel neutron detector by developing and testing small planar prototypes with readout boards suitably segmented with strip or pad read out, equipped with existing electronics or readout in current mode. Preliminary results from the test with different prototypes, showing a good agreement with the simulation, will be presented together with construction details of the prototypes and the future steps of the project.

physics.ins-det

Multilayer $^{10}B$-RPC neutron imaging detector

Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial resolution and timing. However, as for the other types of gaseous detectors with a single layer of $^{10}B_{4}$C at normal beam incidence, the detection efficiency to thermal neutrons of a single-gap $^{10}B$-RPC is only about 6%. Aiming to overcome this limitation, we introduce a multi-layer $^{10}B$-RPCs detector with a stack of ten double-gap hybrid RPCs. A description of the detector design and the results of its characterization performed at the TREFF neutron beamline at the FRM II neutron facility are presented. The results demonstrate that the detection efficiency exceeds 60% for neutrons with a wavelength of 4.7 \r{A} and the spatial resolution (FWHM) is about 0.25 mm and 0.35 mm in the X and Y direction, respectively.

physics.ins-det

The Multi-Blade Boron-10-based neutron detector performance using a focusing reflectometer

The Multi-Blade is a Boron-10-based neutron detector designed for neutron reflectometers and developed for the two instruments (Estia and FREIA) planned for the European Spallation Source in Sweden. A reflectometry demonstrator has been installed at the AMOR reflectometer at the Paul Scherrer Institut (PSI - Switzerland). The setup exploits the Selene guide concept and it can be considered a scaled-down demonstrator of Estia. The results of these tests are discussed. It will be shown how the characteristics of the Multi-Blade detector are features that allow the focusing reflectometry operation mode. Additionally the performance of the Multi-Blade, in terms of rate capability, exceeds current state-of-the-art technology. The improvements with respect to the previous prototypes are also highlighted; from background considerations to the linear and angular uniformity response of the detector.

physics.ins-det

Boron-10 lined RPCs for sub-millimeter resolution thermal neutron detectors: Feasibility study in a thermal neutron beam

The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium cathode lined with a 2 ${\mu}$m thick $^{10}B{_4}C$ neutron converter layer enriched in $^{10}B$ and a float glass anode. A detection efficiency of ${\approx}$ 6.2 ${\%}$ was measured for the neutron beam (${\lambda}$ =2.5 ${\AA}$) at normal incidence. A spatial resolution better than 0.5 mm FWHM was demonstrated.

physics.ins-det

Neutron reflectometry with the Multi-Blade 10B-based detector

The Multi-Blade is a Boron-10-based gaseous detector developed for neutron reflectometry instruments at the European Spallation Source (ESS) in Sweden. The main challenges for neutron reflectometry detectors are the instantaneous counting rate and spatial resolution. The Multi-Blade has been tested on the CRISP reflectometer at the ISIS neutron and muon source in UK. A campaign of scientific measurements has been performed to study the Multi-Blade response in real instrumental conditions. The results of these tests are discussed in this manuscript.

physics.ins-det

Characterization of the Multi-Blade 10B-based detector at the CRISP reflectometer at ISIS for neutron reflectometry at ESS

The Multi-Blade is a Boron-10-based gaseous thermal neutron detector developed to face the challenge arising in neutron reflectometry at neutron sources. Neutron reflectometers are challenging instruments in terms of instantaneous counting rate and spatial resolution. This detector has been designed according to the requirements given by the reflectometers at the European Spallation Source (ESS) in Sweden. The Multi-Blade has been installed and tested on the CRISP reflectometer at the ISIS neutron and muon source in UK. The results on the detailed detector characterization are discussed in this manuscript.

physics.ins-det

Multi-Grid Detector for Neutron Spectroscopy: Results Obtained on Time-of-Flight Spectrometer CNCS

The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demonstrator has an active area of 0.2 m$^2$. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the $^3$He detectors simultaneously, showing that all features recorded by one detector are also recorded by the other. The energy resolution matches closely. We find that the Multi-Grid is able to match the data collected by $^3$He, and see an indication of a considerable advantage in the count rate capability. Based on these results, we are confident that the Multi-Grid detector will be capable of producing high quality scientific data on chopper spectrometers utilising the unprecedented neutron flux of the ESS.

physics.ins-det