Searcharxiv⌕ Search

arXiv subjects

L. T. Yang

Publications and source records attributed to L. T. Yang.

44 records · Page 3Linked to original sources

Bulk and Surface Event Identification in p-type Germanium Detectors

The p-type point-contact germanium detectors have been adopted for light dark matter WIMP searches and the studies of low energy neutrino physics. These detectors exhibit anomalous behavior to events located at the surface layer. The previous spectral shape method to identify these surface events from the bulk signals relies on spectral shape assumptions and the use of external calibration sources. We report an improved method in separating them by taking the ratios among different categories of in situ event samples as calibration sources. Data from CDEX-1 and TEXONO experiments are re-examined using the ratio method. Results are shown to be consistent with the spectral shape method.

physics.ins-det↗

Constraints on Axion couplings from the CDEX-1 experiment at the China Jinping Underground Laboratory

We report the results of searches for solar axions and galactic dark matter axions or axion-like particles with CDEX-1 experiment at the China Jinping Underground Laboratory, using 335.6 kg-days of data from a p-type point-contact germanium detector. The data are compatible with the background model and no excess signals are observed. Limits of solar axions on the model independent coupling $g_{Ae}<2.5\times10^{-11}$ from Compton, bremsstrahlung, atomic-recombination and deexcitation channel and $g^{\text{eff}}_{AN}\times g_{Ae}<6.1\times10^{-17}$ from $^{57}$Fe M1 transition at 90 % confidence level are derived. Within the framework of the DFSZ and KSVZ models, our results exclude the axion mass heavier than 0.9 eV/c$^{2}$ and 173 eV/c$^{2}$, respectively. The derived constraints for dark matter axions below 1 keV improves over the previous results.

hep-ex↗

Characterization and Performance of Germanium Detectors with sub-keV Sensitivities for Neutrino and Dark Matter Experiments

Germanium ionization detectors with sensitivities as low as 100 eVee (electron-equivalent energy) open new windows for studies on neutrino and dark matter physics. The relevant physics subjects are summarized. The detectors have to measure physics signals whose amplitude is comparable to that of pedestal electronic noise. To fully exploit this new detector technique, various experimental issues including quenching factors, energy reconstruction and calibration, signal triggering and selection as well as evaluation of their associated efficiencies have to be attended. The efforts and results of a research program to address these challenges are presented.

physics.ins-det↗

A Search of Low-Mass WIMPs with p-type Point Contact Germanium Detector in the CDEX-1 Experiment

The CDEX-1 experiment conducted a search of low-mass (< 10 GeV/c2) Weakly Interacting Massive Particles (WIMPs) dark matter at the China Jinping Underground Laboratory using a p-type point-contact germanium detector with a fiducial mass of 915 g at a physics analysis threshold of 475 eVee. We report the hardware set-up, detector characterization, data acquisition and analysis procedures of this experiment. No excess of unidentified events are observed after subtraction of known background. Using 335.6 kg-days of data, exclusion constraints on the WIMP-nucleon spin-independent and spin-dependent couplings are derived.

hep-ex↗

Measurement of the dead layer thickness in a p-type point contact germanium detector

A 994g mass p-type PCGe detector was deployed by the first phase of the China Dark matter EXperiment aiming at the direct searches of light weakly interacting massive particles. Measuring the thickness of the dead layer of a p-type germanium detector is an issue of major importance since it determines the fiducial mass of the detector. This work reports a method using an uncollimated 133Ba source to determine the dead layer thickness. The experimental design, data analysis and Monte Carlo simulation processes, as well as the statistical and systematic errors are described. An agreement between the experimental data and simulation results was achieved to derive the thickness of the dead layer of 1.02 mm.

physics.ins-det↗

Limits on light WIMPs from the CDEX-1 experiment with a p-type point-contact germanium detector at the China Jingping Underground Laboratory

We report results of a search for light Dark Matter WIMPs with CDEX-1 experiment at the China Jinping Underground Laboratory, based on 53.9 kg-days of data from a p-type point-contact germanium detector enclosed by a NaI(Tl) crystal scintillator as anti-Compton detector. The event rate and spectrum above the analysis threshold of 475 eVee are consistent with the understood background model. Part of the allowed regions for WIMP-nucleus coherent elastic scattering at WIMP mass of 6-20 GeV are probed and excluded. Independent of interaction channels, this result contradicts the interpretation that the anomalous excesses of the CoGeNT experiment are induced by Dark Matter, since identical detector techniques are used in both experiments.

hep-ex↗

Limits on light WIMPs with a germanium detector at 177 eVee threshold at the China Jinping Underground Laboratory

The China Dark Matter Experiment reports results on light WIMP dark matter searches at the China Jinping Underground Laboratory with a germanium detector array with a total mass of 20 g. The physics threshold achieved is 177 eVee ("ee" represents electron equivalent energy) at 50% signal efficiency. With 0.784 kg-days of data, exclusion region on spin-independent coupling with the nucleon is derived, improving over our earlier bounds at WIMP mass less than 4.6 GeV.

hep-ex↗

First results on low-mass WIMP from the CDEX-1 experiment at the China Jinping underground Laboratory

The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China Jinping underground Laboratory where the rock overburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent cross-section at WIMP mass of 7 GeV before differentiating bulk signals from the surface backgrounds.

hep-ex↗