Searcharxiv⌕ Search

arXiv subjects

L. Terenzi

Publications and source records attributed to L. Terenzi.

46 records · Page 3Linked to original sources

Cryogenic environment and performance for testing the Planck radiometers

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two dedicated cryogenic facilities. In this paper the facilities and the related instrumentation are described. The main satellite thermal interfaces for the single chains have to be reproduced and stability requirements have to be satisfied. Setup design, problems occurred and improving solutions implemented are discussed. Performance of the cryogenic setup are reported.

astro-ph.IM↗

Cryogenic characterization of the Planck sorption cooler system flight model

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221 Two continuous closed-cycle hydrogen Joule-Thomson (J-T) sorption coolers have been fabricated and assembled by the Jet Propulsion Laboratory (JPL) for the European Space Agency (ESA) Planck mission. Each refrigerator has been designed to provide a total of ~ 1W of cooling power at two instrument interfaces: they directly cool the Planck Low Frequency Instrument (LFI) around 20K while providing a pre-cooling stage for a 4 K J-T mechanical refrigerator for the High Frequency Instrument (HFI). After sub-system level validation at JPL, the cryocoolers have been delivered to ESA in 2005. In this paper we present the results of the cryogenic qualification and test campaigns of the Nominal Unit on the flight model spacecraft performed at the CSL (Centre Spatial de Liege) facilities in 2008. Test results in terms of input power, cooling power, temperature, and temperature fluctuations over the flight allowable ranges for these interfaces are reported and analyzed with respect to mission requirements.

astro-ph.IM↗

Level 1 on-ground telemetry handling in Planck LFI

The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data source are the temperature samples acquired by the 22 radiometers mounted on the Planck focal plane. Such samples represent the scientific data of LFI. In addition, the LFI instrument generates the so called housekeeping data by sampling regularly the on-board sensors and registers. The housekeeping data provides information on the overall health status of the instrument and on the scientific data quality. The scientific and housekeeping data are collected on-board into telemetry packets compliant with the ESA Packet Telemetry standards. They represent the primary input to the first processing level of the LFI Data Processing Centre. In this work we show the software systems which build the LFI Level 1. A real-time assessment system, based on the ESA SCOS 2000 generic mission control system, has the main purpose of monitoring the housekeeping parameters of LFI and detect possible anomalies. A telemetry handler system processes the housekeeping and scientific telemetry of LFI, generating timelines for each acquisition chain and each housekeeping parameter. Such timelines represent the main input to the subsequent processing levels of the LFI DPC. A telemetry quick-look system allows the real-time visualization of the LFI scientific and housekeeping data, by also calculating quick statistical functions and fast Fourier transforms. The LFI Level 1 has been designed to support all the mission phases, from the instrument ground tests and calibration to the flight operations, and developed according to the ESA engineering standards.

astro-ph.IM↗

Off-line radiometric analysis of Planck/LFI data

The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features of LIFE is its ability to run the same data analysis codes both using ground test data and real flight data as input. The LIFE software suite has been successfully used during the RCA/RAA tests and the Planck Integrated System Tests. Moreover, the software has also passed the verification for its in-flight use during the System Operations Verification Tests, held in October 2008.

astro-ph.IM↗

Dynamic validation of the Planck/LFI thermal model

The Low Frequency Instrument (LFI) is an array of cryogenically cooled radiometers on board the Planck satellite, designed to measure the temperature and polarization anisotropies of the cosmic microwave backgrond (CMB) at 30, 44 and 70 GHz. The thermal requirements of the LFI, and in particular the stringent limits to acceptable thermal fluctuations in the 20 K focal plane, are a critical element to achieve the instrument scientific performance. Thermal tests were carried out as part of the on-ground calibration campaign at various stages of instrument integration. In this paper we describe the results and analysis of the tests on the LFI flight model (FM) performed at Thales Laboratories in Milan (Italy) during 2006, with the purpose of experimentally sampling the thermal transfer functions and consequently validating the numerical thermal model describing the dynamic response of the LFI focal plane. This model has been used extensively to assess the ability of LFI to achieve its scientific goals: its validation is therefore extremely important in the context of the Planck mission. Our analysis shows that the measured thermal properties of the instrument show a thermal damping level better than predicted, therefore further reducing the expected systematic effect induced in the LFI maps. We then propose an explanation of the increased damping in terms of non-ideal thermal contacts.

astro-ph.IM↗

Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.

astro-ph.IM↗

The Planck Low Frequency Instrument

Planck is the third generation of mm-wave instruments designed for space observations of the cosmic microwave background (CMB) anisotropies within the new Cosmic Vision 2020 ESA Science Program. Planck will map the whole sky with unprecedented sensitivity, angular resolution, and frequency coverage, and it likely leads us to the final comprehension of the CMB anisotropies. The Low Frequency Instrument (LFI), operating in the 30-70 GHz range, is one of the two instruments onboard Planck satellite, sharing the focal region of a 1.5 meter off-axis dual reflector telescope together with the High Frequency Instrument (HFI) operating at 100-857 GHz. We present LFI and discuss the major instrumental systematic effects that could degrade the measurements and the solutions adopted in the design and data analysis phase in order to adequately reduce and control them.

astro-ph↗

Planck Low Frequency Instrument: Beam Patterns

The Low Frequency Instrument on board the ESA Planck satellite is coupled to the Planck 1.5 meter off-axis dual reflector telescope by an array of 27 corrugated feed horns operating at 30, 44, 70, and 100 GHz. We briefly present here a detailed study of the optical interface devoted to optimize the angular resolution (10 arcmin at 100 GHz as a goal) and at the same time to minimize all the systematics coming from the sidelobes of the radiation pattern. Through optical simulations, we provide shapes, locations on the sky, angular resolutions, and polarization properties of each beam.

astro-ph↗

Sources Variability With Planck LFI

Planck LFI (Low Frequency Instrument) will produce a complete survey of the sky at millimeter wavelengths. Data stream analysis will provide the possibility to reveal unexpected millimeter sources and to study their flux evolution in time at different frequencies. We describe here the main implications and discuss data analysis methods. Planck sensitivities typical for this kind of detection are taken into account. We present also preliminary results of our simulation activity.

astro-ph↗

The Planck Telescope

In this paper we present an overview of the Telescope designed for ESA's mission dedicated to map the Cosmic Microwave Background Anisotropies and Polarization. Two instruments, LFI and HFI, operate in an overall frequency range between 25 and 900 GHz and share the focal region of the 1.5 meter optimized telescope. The optimization techniques adopted for the optical design and the telescope characteristic are reported and discussed.

astro-ph↗