SearcharxivSearch

arXiv subjects

L. Tomassetti

Publications and source records attributed to L. Tomassetti.

9 recordsLinked to original sources

Cryogenic characterization of FBK NUV-HD-Cryo 3T SiPM sensors for the DUNE photon detection system

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino experiment based in the USA and composed of a Near Detector (ND) complex at Fermi National Laboratory (FNAL), and a Far Detector (FD) complex located at the Sanford Underground Research Facility (SURF) $\sim$1300\,km distant. DUNE will study neutrino oscillations looking for unresolved issues of the Standard Model of particle physics (SM) such as CP violation in the leptonic sector, neutrino mass ordering and others, starting from the early 2030s. The FD, with a mass of $\sim$17\,kt, that will exploit both ionization and scintillation signals to detect neutrino interactions with Argon. Scintillating photons in LAr will be detected by the photon detection system (PDS) based on light collectors coupled to Silicon Photomultipliers (SiPMs). During a test campaign, different laboratories of the collaboration performed an investigation of the best SiPM candidates that fulfill the DUNE FD requirements. We identified two models of SiPM, produced by Hamamatsu Photonics K.K. (HPK) and Fondazione Bruno Kessler (FBK), respectively. In this paper, we focus on the FBK selected model showing its main features. We will describe the characterization protocol, the results at both room and cryogenic temperatures and the photon detection efficiency measurements.

physics.ins-det

Cryogenic front-end amplifier design for large SiPM arrays in the DUNE FD1-HD photon detection system

The photon detection system of the first far detector (FD1-HD) of the DUNE experiment will detect scintillation photons produced by particle interactions in a kiloton-scale liquid Argon time projection chamber. The photon detectors of choice are silicon photomultipliers (SiPM), 6$\times$6 mm$^2$ each, arranged in groups of 48, which present a significantly low impedance to the front-end electronics. This paper details the design of a cryogenic amplifier with exceptionally low white voltage noise of 0.37 nV$\sqrt{Hz}$, based on a silicon-germanium input transistor and a BiCMOS fully differential operational amplifier. It yields excellent single photoelectron resolution even at low overvoltage values. The signal rise time is below 100 ns, and the dynamic range is about 2000 photoelectrons at the typical operating overvoltage. It draws 0.7 mA from a single 3.3 V supply, for a power consumption of 2.4 mW per channel. Simplified models were developed to predict the single photolectron signal shape and the signal to noise ratio, with a good match to measured performance.

physics.ins-det

Performance of the LHCb RICH detectors during LHC Run 2

The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and running conditions is measured. The particle identification performance is evaluated with data and found to satisfy the requirements of the physics programme.

physics.ins-det

Coded masks for imaging of neutrino events

The capture of scintillation light emitted by liquid Argon and Xenon under molecular excitations by charged particles is still a challenging task. Here we present a first attempt to design a device able to grab sufficiently high luminosity in order to reconstruct the path of ionizing particles. This preliminary study is based on the use of masks to encode the light signal combined with single-photon detectors. In this respect, the proposed system is able to detect tracks over focal distances of about tens of centimeters. From numerical simulations it emerges that it is possible to successfully decode and recognize signals, even complex, with a relatively limited number of acquisition channels. Such innovative technique can be very fruitful in a new generation of detectors devoted to neutrino physics and dark matter search. Indeed the introduction of coded masks combined with SiPM detectors is proposed for a liquid-Argon target in the Near Detector of the DUNE experiment.

physics.ins-det

Test of the photon detection system for the LHCb RICH Upgrade in a charged particle beam

The LHCb detector will be upgraded to make more efficient use of the available luminosity at the LHC in Run III and extend its potential for discovery. The Ring Imaging Cherenkov detectors are key components of the LHCb detector for particle identification. In this paper we describe the setup and the results of tests in a charged particle beam, carried out to assess prototypes of the upgraded opto-electronic chain from the Multi-Anode PMT photosensor to the readout and data acquisition system.

physics.ins-det

Long-term drift laser frequency stabilization using purely optical reference

We describe an apparatus for the stabilization of laser frequencies that prevents long term frequency drifts. A Fabry-Perot interferometer is thermostated by referencing it to a stabilized He-Ne laser (master), and its length is scanned over more than one free spectral range allowing the analysis of one or more lines generated by other (slave) lasers. A digital acquisition system makes the detection of the position of all the laser peaks possible, thus producing both feedback of both the thermostat and the error signal used for stabilizing the slave lasers. This technique also allows for easy, referenced scanning of the slave laser frequencies over range of several hundred MHz, with a precision of the order of a few MHz. This kind of stabilization system is particularly useful when no atomic or molecular reference lines are available, as in the case of rare or short lived radioactive species.

physics.ins-det

Experimental study of vapor-cell magneto-optical traps for efficient trapping of radioactive atoms

We have studied magneto-optical traps (MOTs) for efficient on-line trapping of radioactive atoms. After discussing a model of the trapping process in a vapor cell and its efficiency, we present the results of detailed experimental studies on Rb MOTs. Three spherical cells of different sizes were used. These cells can be easily replaced, while keeping the rest of the apparatus unchanged: atomic sources, vacuum conditions, magnetic field gradients, sizes and power of the laser beams, detection system. By direct comparison, we find that the trapping efficiency only weakly depends on the MOT cell size. It is also found that the trapping efficiency of the MOT with the smallest cell, whose diameter is equal to the diameter of the trapping beams, is about 40% smaller than the efficiency of larger cells. Furthermore, we also demonstrate the importance of two factors: a long coated tube at the entrance of the MOT cell, used instead of a diaphragm; and the passivation with an alkali vapor of the coating on the cell walls, in order to minimize the losses of trappable atoms. These results guided us in the construction of an efficient large-diameter cell, which has been successfully employed for on-line trapping of Fr isotopes at INFN's national laboratories in Legnaro, Italy.

physics.atom-ph

Measurement of diffusion coefficients of francium and rubidium in yttrium based on laser spectroscopy

We report the first measurement of the diffusion coefficients of francium and rubidium ions implanted in a yttrium foil. We developed a methodology, based on laser spectroscopy, which can be applied to radioactive and stable species, and allows us to directly take record of the diffusion time. Francium isotopes are produced via fusion-evaporation nuclear reaction of a 100 MeV 18-O beam on a Au target at the Tandem XTU accelerator facility in Legnaro, Italy. Francium is ionized at the gold-vacuum interface and Fr+ ions are then transported with a 3 keV electrostatic beamline to a cell for neutralization and capture in a magneto-optical trap (MOT). A Rb+ beam is also available, which follows the same path as Fr+ ions. The accelerated ions are focused and implanted in a 25 um thick yttrium foil for neutralization: after diffusion to the surface, they are released as neutrals, since the Y work function is lower than the alkali ionization energies. The time evolution of the MOT and the vapor fluorescence signals are used to determine diffusion times of Fr and Rb in Y as a function of temperature.

physics.atom-ph

High-Precision Measurement of the Laser-Trapping Frequencies for $^{209,210,211}$Fr Atoms

We present the accurate measurement of the frequency of the $7S-7P$ laser-trapping transition for three francium isotopes. Our approach is based on an interferometric comparison to deduce the unknown laser frequency from a secondary laser frequency-standard. After careful investigation of systematics, with samples of about 100 atoms the final accuracy reaches 8 MHz, an order of magnitude better than the best previous measurement for $^{210}$Fr, and opens the way to improved tests of the theoretical computation of Fr atomic structure.

physics.atom-ph