SearcharxivSearch

arXiv subjects

L. Zanotti

Publications and source records attributed to L. Zanotti.

9 recordsLinked to original sources

Effective exploitation of a geyser bubble-chamber equipment as a background-free fast neutron detector

MOSCAB equipment, a geyser-concept bubble-chamber originally thought for the search of dark matter in the form of WIMPs, is employed for the detection of fast neutrons. Once the background-free operating conditions are determined such that the detector is sensitive only to neutrons, which occurs when the neutron energy threshold required for nucleation is higher than approximately 2.5 MeV, the detector response to fast neutrons is investigated using an AmBe neutron source. Sets of detection efficiency functions are then produced via Monte Carlo simulations and post-processing, their validation being performed experimentally and discussed. Finally, the use of the detector to measure the fast neutron activity of very weak n-sources in clean environments, as well as to monitor the cosmic ray variations through the neutron component of the Extensive Air Showers, is considered.

physics.ins-det

On the critical energy required for homogeneous nucleation in bubble chambers employed in dark matter searches

Two equations for the calculation of the critical energy required for homogeneous nucleation in a superheated liquid, and the related critical radius of the nucleated vapour bubble, are obtained, the former by the direct application of the first law of thermodynamics, the latter by considering that the bubble formation implies the overcoming of a barrier of the free enthalpy potential. Comparisons with the currently used relationships demonstrate that the sensitivity of the bubble chambers employed in dark matter searches can be sometimes notably overestimated.

hep-ex

MOSCAB: A geyser-concept bubble chamber to be used in a dark matter search

The MOSCAB experiment (Materia OSCura A Bolle) uses the "geyser technique", a variant of the superheated liquid technique of extreme simplicity. Operating principles of the new dark matter detector and technical solutions of the device are reported in detail. First results obtained in a series of test runs taken in laboratory demonstrate that we have successfully built and tested a geyser-concept bubble chamber that can be used in particle physics, especially in dark matter searches, and that we are ready to move underground for extensive data taking.

physics.ins-det

A new technique for direct investigation of dark matter

The MOSCAB experiment (Materia OSCura A Bolle) uses a new technique for Dark Matter search. The Geyser technique is applied to the construction of a prototype detector with a mass of 0.5 kg and the encouraging results are reported here; an accent is placed on a big detector of 40 kg in construction at the Milano-Bicocca University and INFN.

astro-ph.IM

Complete results for five years of GNO solar neutrino observations

We report the complete GNO solar neutrino results for the measuring periods GNO III, GNO II, and GNO I. The result for GNO III (last 15 solar runs) is [54.3 + 9.9 - 9.3 (stat.)+- 2.3 (syst.)] SNU (1 sigma) or [54.3 + 10.2 - 9.6 (incl. syst.)] SNU (1 sigma) with errors combined. The GNO experiment is now terminated after altogether 58 solar exposure runs that were performed between May 20, 1998 and April 9, 2003. The combined result for GNO (I+II+III) is [62.9 + 5.5 - 5.3 (stat.) +- 2.5 (syst.)] SNU (1 sigma) or [62.9 + 6.0 - 5.9] SNU (1 sigma) with errors combined in quadrature. Overall, gallium based solar observations at LNGS (first in GALLEX, later in GNO) lasted from May 14, 1991 through April 9, 2003. The joint result from 123 runs in GNO and GALLEX is [69.3 +- 5.5 (incl. syst.)] SNU (1 sigma). The distribution of the individual run results is consistent with the hypothesis of a neutrino flux that is constant in time. Implications from the data in particle- and astrophysics are reiterated.

hep-ex

CUORE: A Cryogenic Underground Observatory for Rare Events

CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers of 4 crystals. The design of the detector is optimized for ultralow-background searches: for neutrinoless double beta decay of 130Te (33.8% abundance), cold dark matter, solar axions, and rare nuclear decays. A preliminary experiment involving 20 crystals 3x3x6 cm3 of 340 g has been completed, and a single CUORE tower is being constructed as a smaller scale experiment called CUORICINO. The expected performance and sensitivity, based on Monte Carlo simulations and extrapolations of present results, are reported.

hep-ex

New Limits on Naturally Occurring Electron Capture of 123Te

Electron capture of 123Te from the K shell has been investigated in a new underground search with an array of 340 g TeO_2 thermal detectors. We find that some previous indication of this decay could be attributed to E.C. of 121Te resulting from neutron activation of natural Tellurium. There is therefore so far no evidence for E.C. of 123Te from the K shell with a 90 % c.l. lower limit t_{1/2}^K > 5.E19 years on the half lifetime. Taking into account the predicted K E.C. branching ratio, the corresponding lower limit on the 123Te EC half lifetime is t_{1/2} > 9.2E16 y, which can be theoretically interpreted only on the basis of a strong suppression of the nuclear matrix elements. A complementary analysis based on the expected fraction of E.C. accompanied by internal bremsstrahlung is discussed.

hep-ex

GNO Solar Neutrino Observations: Results for GNOI

We report the first GNO solar neutrino results for the measuring period GNOI, solar exposure time May 20, 1998 till January 12, 2000. In the present analysis, counting results for solar runs SR1 - SR19 were used till April 4, 2000. With counting completed for all but the last 3 runs (SR17 - SR19), the GNO I result is [65.8 +10.2 -9.6 (stat.) +3.4 -3.6 (syst.)]SNU (1sigma) or [65.8 + 10.7 -10.2 (incl. syst.)]SNU (1sigma) with errors combined. This may be compared to the result for Gallex(I-IV), which is [77.5 +7.6 -7.8 (incl. syst.)] SNU (1sigma). A combined result from both GNOI and Gallex(I-IV) together is [74.1 + 6.7 -6.8 (incl. syst.)] SNU (1sigma).

hep-ex