Searcharxiv⌕ Search

arXiv subjects

Lakshmana D Chandrala

Publications and source records attributed to Lakshmana D Chandrala.

3 recordsLinked to original sources

Vortex ring formation from the interaction of a cavitation bubble with a confined air bubble: experiments and a timing criterion

We study vortex ring formation arising from the interaction between a cavitation bubble and a confined air bubble in a cylindrical blind hole, using high-speed shadowgraphy imaging. As the cavitation bubble grows above the hole, it drives a downward flow that compresses the air bubble at the base. The air bubble subsequently expands, expelling the overlying liquid column upward as a coherent slug; impact of this slug on the far boundary of the collapsing cavitation bubble produces a vortex ring. Parametric experiments across the dimensionless stand-off distance $\mathcal{H} = h/R_{\max}$ and the air bubble fill fraction $\mathcal{B} = (d_\text{hole} - d_\text{top})/d_\text{hole}$ identify three regimes: (i) liquid column impact during collapse, producing a vortex ring ($\mathcal{H} \lesssim 0.5$, $\mathcal{B} \lesssim 0.5$); (ii) late impact near the end of collapse (large $\mathcal{H}$); and (iii) direct air bubble impact after bypassing the liquid column (large $\mathcal{B}$), with neither (ii) nor (iii) producing a ring. Two one-dimensional models, based on the Rayleigh-Plesset equation and isentropic air bubble expansion, predict the liquid column impact location and its speed $U_\text{lc}$, respectively. A dimensionless timing parameter $Π= (h + R_{\max}) / (U_\text{lc} \cdot t_\text{cav}/2)$, comparing the liquid column travel time to the cavitation collapse half-period, distinguishes the three regimes: ring formation occurs for $1 \lesssim Π\lesssim 1.5$. The ring propagates from the hole at an initial speed of $5$ m/s, decelerating quadratically, and breaks apart via azimuthal instabilities at $Re \approx 4500$.

physics.flu-dyn↗

An experimental investigation of flow fields near a liquid-liquid moving contact line

A moving contact line occurs at the intersection of an interface formed between two immiscible liquids and a solid. According to viscous theory, the flow is entirely governed by just two parameters, the viscosity ratio, $λ$, and the dynamic contact angle, $θ_d$. While a majority of experimental studies on moving contact lines involve determining the relationship between the dynamic contact angle and capillary number, a few studies have focused on measuring the flow field in the vicinity of the contact line involving liquid-gas interfaces. However, none of the studies have considered liquid-liquid moving contact lines and the present study fills this vital gap. Using particle image velocimetry, we simultaneously measure the velocity field in both the liquid phases using refractive index matching techniques. The flow field obtained from experiments in both phases is directly compared against theoretical models. Measurement of interface speed reveals that material points rapidly slow down as the contact line is approached. Further, the experiments also reveal the presence of slip along the moving wall in the vicinity of the contact line suggesting a clear mechanism for how the singularity is arrested at the contact line.

physics.flu-dyn↗

An experimental study of flow near an advancing contact line: a rigorous test of theoretical models

The flow near a moving contact line depends on the dynamic contact angle, viscosity ratio, and capillary number. We report experiments involving immersing a plate into a liquid bath, concurrently measuring the interface shape, interfacial velocity, and fluid flow using digital image processing and particle image velocimetry. All experiments were performed at low plate speeds to maintain small Reynolds and capillary numbers for comparison with viscous theories. The dynamic contact angle, measured in the viscous phase, was kept below $90^{\circ}$, an unexplored region of parameter space. An important aim of the present study is to provide valuable experimental data using which new contact line models can be developed and validated. Interface shapes reveal that the strong viscous bending predicted by theoretical models is absent in the experimental data. The flow field is directly compared against the prediction from the viscous theory of \cite{huh1971hydrodynamic} but with a slight modification involving the curved interface. Remarkable agreement is found between experiments and theory across a wide parameter range. The prediction for interfacial speed from \cite{huh1971hydrodynamic} is also in excellent agreement with experiments except in the vicinity of the contact line. Material points along the interface were found to rapidly slow down near the contact line, thus alleviating the singularity at the moving contact line. To the best of our knowledge, such a detailed test of theoretical models has not been performed before and we hope the present study will spur new modeling efforts in the field.

physics.flu-dyn↗