SearcharxivSearch

arXiv subjects

Laurence Court

Publications and source records attributed to Laurence Court.

7 recordsLinked to original sources

Feasibility of a General-Purpose Deep Learning Dose Engine: A Multi-Site Validation Study

Conventional radiotherapy dose calculation algorithms are often computationally slow and non-differentiable, creating bottlenecks for online adaptive radiotherapy (ART) and limiting end-to-end automatic planning. Deep learning provides consistent inference performance and a differentiable framework essential for rapid optimization. In this study, we developed a generalized, site-independent deep learning dose engine using a beamlet-based input strategy. This establishes a computationally consistent and differentiable module that enables end-to-end training for autoplanning while maintaining accuracy across diverse geometries. A dataset of 3,600 plans from 120 patients across six anatomical sites was used to train two 3D convolutional neural networks, a standard U-Net and a Cascade U-Net, to predict 3D dose distributions from CT images and divergent MLC/jaw projections. Performance was validated via 3D gamma analysis on an independent cohort of 60 VMAT plans. The optimal model (U-Net with MAE loss) achieved a mean gamma passing rate of $98.9 \pm 1.6\%$ (3%/2mm, 10% threshold). Performance remained robust across all sites (passing rates $>98\%$), demonstrating that the beamlet-based strategy generalizes effectively to complex geometries without site-specific training. These results indicate that a single, site-independent model can calculate radiotherapy dose distributions with clinical accuracy. This differentiable engine is highly suitable for integration into end-to-end automatic planning, online ART, and secondary dose verification workflows.

physics.med-ph

Virtual Dosimetrists: A Radiotherapy Training "Flight Simulator"

Effective education in radiotherapy plan quality review requires a robust, regularly updated set of examples and the flexibility to demonstrate multiple possible planning approaches and their consequences. However, the current clinic-based paradigm does not support these needs. To address this, we have developed 'Virtual Dosimetrist' models that can both generate training examples of suboptimal treatment plans and then allow trainees to improve the plan quality through simple natural language prompts, as if communicating with a dosimetrist. The dose generation and modification process is accurate, rapid, and requires only modest resources. This work is the first to combine dose distribution prediction with natural language processing; providing a robust pipeline for both generating suboptimal training plans and allowing trainees to practice their critical plan review and improvement skills that addresses the challenges of the current clinic-based paradigm.

physics.med-ph

DIFR3CT: Latent Diffusion for Probabilistic 3D CT Reconstruction from Few Planar X-Rays

Computed Tomography (CT) scans are the standard-of-care for the visualization and diagnosis of many clinical ailments, and are needed for the treatment planning of external beam radiotherapy. Unfortunately, the availability of CT scanners in low- and mid-resource settings is highly variable. Planar x-ray radiography units, in comparison, are far more prevalent, but can only provide limited 2D observations of the 3D anatomy. In this work we propose DIFR3CT, a 3D latent diffusion model, that can generate a distribution of plausible CT volumes from one or few (<10) planar x-ray observations. DIFR3CT works by fusing 2D features from each x-ray into a joint 3D space, and performing diffusion conditioned on these fused features in a low-dimensional latent space. We conduct extensive experiments demonstrating that DIFR3CT is better than recent sparse CT reconstruction baselines in terms of standard pixel-level (PSNR, SSIM) on both the public LIDC and in-house post-mastectomy CT datasets. We also show that DIFR3CT supports uncertainty quantification via Monte Carlo sampling, which provides an opportunity to measure reconstruction reliability. Finally, we perform a preliminary pilot study evaluating DIFR3CT for automated breast radiotherapy contouring and planning -- and demonstrate promising feasibility. Our code is available at https://github.com/yransun/DIFR3CT.

eess.IV

CT Reconstruction from Few Planar X-rays with Application towards Low-resource Radiotherapy

CT scans are the standard-of-care for many clinical ailments, and are needed for treatments like external beam radiotherapy. Unfortunately, CT scanners are rare in low and mid-resource settings due to their costs. Planar X-ray radiography units, in comparison, are far more prevalent, but can only provide limited 2D observations of the 3D anatomy. In this work, we propose a method to generate CT volumes from few (<5) planar X-ray observations using a prior data distribution, and perform the first evaluation of such a reconstruction algorithm for a clinical application: radiotherapy planning. We propose a deep generative model, building on advances in neural implicit representations to synthesize volumetric CT scans from few input planar X-ray images at different angles. To focus the generation task on clinically-relevant features, our model can also leverage anatomical guidance during training (via segmentation masks). We generated 2-field opposed, palliative radiotherapy plans on thoracic CTs reconstructed by our method, and found that isocenter radiation dose on reconstructed scans have <1% error with respect to the dose calculated on clinically acquired CTs using <=4 X-ray views. In addition, our method is better than recent sparse CT reconstruction baselines in terms of standard pixel and structure-level metrics (PSNR, SSIM, Dice score) on the public LIDC lung CT dataset. Code is available at: https://github.com/wanderinrain/Xray2CT.

eess.IV

Resection cavity auto-contouring for patients with pediatric medulloblastoma using only CT information

Purpose: Target delineation for radiation therapy is a time-consuming and complex task. Autocontouring gross tumor volumes (GTVs) has been shown to increase efficiency. However, there is limited literature on post-operative target delineation, particularly for CT-based studies. To this end, we trained a CT-based autocontouring model to contour the post-operative GTV of pediatric patients with medulloblastoma. Methods: 104 retrospective pediatric CT scans were used to train a GTV auto-contouring model. 80 patients were then preselected for contour visibility, continuity, and location to train an additional model. Each GTV was manually annotated with a visibility score based on the number of slices with a visible GTV (1 = <25%, 2 = 25%-50%, 3 = >50%-75%, and 4 = >75%-100%). Contrast and the contrast-to-noise ratio (CNR) were calculated for the GTV contour with respect to a cropped background image. Both models were tested on the original and pre-selected testing sets. The resulting surface and overlap metrics were calculated comparing the clinical and autocontoured GTVs and the corresponding clinical target volumes (CTVs). Results: 80 patients were pre-selected to have a continuous GTV within the posterior fossa. Of these, 7, 41, 21, and 11 were visibly scored as 4, 3, 2, and 1, respectively. The contrast and CNR removed an additional 11 and 20 patients from the dataset, respectively. The Dice similarity coefficients (DSC) were 0.61 +/- 0.29 and 0.67 +/- 0.22 on the models without pre-selected training data and 0.55 +/- 13.01 and 0.83 +/- 0.17 on the models with pre-selected data, respectively. The DSC on the CTV expansions were 0.90 +/- 0.13. Conclusion: We automatically contoured continuous GTVs within the posterior fossa on scans that had contrast >=10 HU. CT-Based auto-contouring algorithms have potential to positively impact centers with limited MRI access.

physics.med-ph

Automation of Radiation Treatment Planning for Rectal Cancer

To develop an automated workflow for rectal cancer three-dimensional conformal radiotherapy treatment planning that combines deep-learning(DL) aperture predictions and forward-planning algorithms. We designed an algorithm to automate the clinical workflow for planning with field-in-field. DL models were trained, validated, and tested on 555 patients to automatically generate aperture shapes for primary and boost fields. Network inputs were digitally reconstructed radiography, gross tumor volume(GTV), and nodal GTV. A physician scored each aperture for 20 patients on a 5-point scale(>3 acceptable). A planning algorithm was then developed to create a homogeneous dose using a combination of wedges and subfields. The algorithm iteratively identifies a hotspot volume, creates a subfield, and optimizes beam weight all without user intervention. The algorithm was tested on 20 patients using clinical apertures with different settings, and the resulting plans(4 plans/patient) were scored by a physician. The end-to-end workflow was tested and scored by a physician on 39 patients using DL-generated apertures and planning algorithms. The predicted apertures had Dice scores of 0.95, 0.94, and 0.90 for posterior-anterior, laterals, and boost fields, respectively. 100%, 95%, and 87.5% of the posterior-anterior, laterals, and boost apertures were scored as clinically acceptable, respectively. Wedged and non-wedged plans were clinically acceptable for 85% and 50% of patients, respectively. The final plans hotspot dose percentage was reduced from 121%($\pm$ 14%) to 109%($\pm$ 5%) of prescription dose. The integrated end-to-end workflow of automatically generated apertures and optimized field-in-field planning gave clinically acceptable plans for 38/39(97%) of patients. We have successfully automated the clinical workflow for generating radiotherapy plans for rectal cancer for our institution.

physics.med-ph

Automated WBRT Treatment Planning via Deep Learning Auto-Contouring and Customizable Landmark-Based Field Aperture Design

In this work, we developed and evaluated a novel pipeline consisting of two landmark-based field aperture generation approaches for WBRT treatment planning; they are fully automated and customizable. The automation pipeline is beneficial for both clinicians and patients, where we can reduce clinician workload and reduce treatment planning time. The customizability of the field aperture design addresses different clinical requirements and allows the personalized design to become feasible. The performance results regarding quantitative and qualitative evaluations demonstrated that our plans were comparable with the original clinical plans. This technique has been deployed as part of a fully automated treatment planning tool for whole-brain cancer and could be translated to other treatment sites in the future.

eess.IV