SearcharxivSearch

arXiv subjects

Lavsen Dahal

Publications and source records attributed to Lavsen Dahal.

16 recordsLinked to original sources

Virtual Patients, Real Gains: Digital Twin-Based Simulated CT for Multitask Lung Nodule Analysis

AI-based lung cancer screening is constrained by scarce, annotated CT data, particularly for rare nodule presentations. We investigate whether physics-based, anatomy-informed simulated CT can improve AI performance across three lung-nodule tasks: detection, segmentation, and malignancy classification. Using the Virtual Lung Screening Trial framework, we generated 174 digital human twins (XCAT3), embedded 512 procedurally controlled nodules (X-Lesions, 4-30 mm), and simulated CT (DukeSim) under two scanner configurations, yielding 1,044 annotated scans. Combined with clinical data, these trained models for detection (MONAI), segmentation (VISTA3D, nnU-Net), and classification (Med3D), evaluated on external test sets. Detection sensitivity at 1 FP/scan rose from 0.37 to 0.56 (p < 0.001); segmentation improved modestly (Dice 0.61 to 0.64, 0.66 to 0.69); classification AUC rose from 0.78 to 0.87 (p < 0.001). Physics-based virtual imaging trials can help address data scarcity in medical AI.

cs.LG

ORACLE-CT: Anatomy-Aware Support Pooling for CT Classification

Abdominal CT disease classification is challenging because each scan is a large 3D volume with many possible findings, while diagnostic evidence is often confined to specific organs or anatomical compartments. Most study-level classifiers aggregate encoder features using anatomy-agnostic pooling or attention, creating a mismatch between localized disease evidence and global evidence aggregation. We propose ORACLE--CT, an encoder-agnostic anatomy-aware aggregation framework that uses multi-organ segmentation to define label-specific anatomical supports and restrict attention pooling to relevant regions. The framework supports single-organ, multi-organ union, comparative, localized, and global support strategies. We evaluate ORACLE--CT with three encoder families: DINOv3, I3D--ResNet-121, and the radiology-native Pillar--0 encoder. Models are trained end-to-end on MERLIN and evaluated internally and under frozen external transfer to Duke--Abdomen and AMOS. Compared with global average pooling, support-masked pooling improved MERLIN macro-AUROC/AUPRC from 0.838/0.638 to 0.858/0.676 for DINOv3 and from 0.829/0.617 to 0.848/0.659 for I3D--ResNet-121. On harmonized 10-label external evaluation, DINOv3 improved on Duke--Abdomen from 0.802/0.628 to 0.835/0.683 and on AMOS from 0.742/0.313 to 0.762/0.350, with similar gains for I3D--ResNet-121. For Pillar--0, most gains came from learned attention, with smaller additional benefit from anatomical masking. ORACLE--CT improves discrimination and external robustness while preserving an auditable link between predictions and anatomical evidence.

cs.CV

JANUS: Anatomy-Conditioned Gating for Robust CT Triage Under Distribution Shift

Automated CT triage requires models that are simultaneously accurate across diverse pathologies and reliable under institutional shift. While Vision Transformers provide strong visual representations, many clinically significant findings are defined by quantitative imaging biomarkers rather than appearance alone. We introduce JANUS, a physiology-guided dual-stream architecture that conditions visual embeddings on macro-radiomic priors via Anatomically Guided Gating. On the MERLIN test set (N=5082), JANUS attains macro-AUROC 0.88 and AUPRC 0.74, outperforming all reproduced baselines. It generalizes to an external dataset N=2000; AUROC 0.87), with the largest gains on findings defined by size and attenuation as well as improved calibration on both datasets. We further quantify prediction suppression using the Physiological Veto Rate (PVR), showing that under domain shift JANUS reduces high-confidence false positives substantially more often than true positives. Together, these results are consistent with physically grounded conditioning that improves both discrimination and reliability in CT triage. Code is made publicly available at github repository https://github.com/lavsendahal/janus and model weights are at https://huggingface.co/lavsendahal/janus.

cs.CV

CT-IDP: Segmentation-Derived Quantitative Phenotypes for Interpretable Abdominal CT Disease Classification

In this retrospective multi-institutional study, a quantitative phenotyping framework, CT-IDP (CT Image-Derived Phenotypes) was developed on the MERLIN abdominal CT benchmark (training, validation, and test sets- 15,175, 5,018, and 5,082 studies, respectively) and externally evaluated on two independent dataset: Duke-Abdomen (2,000) and AMOS (1,107). Multi-organ segmentations were generated with TotalSegmentator and used to derive over 900 organ and compartment-level descriptors spanning morphometry, attenuation, and contextual/burden findings. Sparse disease-specific logistic regression with elastic-net regularization was trained on MERLIN and externally validated under a frozen specification. Performance was compared against a DINOv3-based vision-transformer baseline using AUC and average precision (AP), supported by phenotype-stratified audits and coefficient-level inspection. Macro-AUC for CT-IDP versus the baseline was 0.897 versus 0.880 on MERLIN, 0.877 versus 0.857 on the Duke-Abdomen dataset, and 0.780 versus 0.756 on AMOS.

cs.CV

AbdomenGen: Sequential Volume-Conditioned Diffusion Framework for Abdominal Anatomy Generation

Computational phantoms are widely used in medical imaging research, yet current systems to generate controlled, clinically meaningful anatomical variations remain limited. We present AbdomenGen, a sequential volume-conditioned diffusion framework for controllable abdominal anatomy generation. We introduce the \textbf{Volume Control Scalar (VCS)}, a standardized residual that decouples organ size from body habitus, enabling interpretable volume modulation. Organ masks are synthesized sequentially, conditioning on the body mask and previously generated structures to preserve global anatomical coherence while supporting independent, multi-organ control. Across 11 abdominal organs, the proposed framework achieves strong geometric fidelity (e.g., liver dice $0.83 \pm 0.05$), stable single-organ calibration over $[-3,+3]$ VCS, and disentangled multi-organ modulation. To showcase clinical utility with a hepatomegaly cohort selected from MERLIN, Wasserstein-based VCS selection reduces distributional distance of training data by 73.6\% . These results demonstrate calibrated, distribution-aware anatomical generation suitable for controllable abdominal phantom construction and simulation studies.

cs.CV

Reproducible Benchmarking for Lung Nodule Detection and Malignancy Classification Across Multiple Low-Dose CT Datasets

Evaluation of artificial intelligence (AI) models for low-dose CT lung cancer screening is limited by heterogeneous datasets, annotation standards, and evaluation protocols, making performance difficult to compare and translate across clinical settings. We establish a public, reproducible multi-dataset benchmark for lung nodule detection and nodule-level cancer classification and quantify cross-dataset generalizability. Using the Duke Lung Cancer Screening (DLCS) dataset as a clinically curated development set, we evaluate performance across LUNA16/LIDC-IDRI, NLST-3D, and LUNA25. Detection models trained on DLCS and LUNA16 were evaluated externally on NLST-3D using free-response ROC analysis. For malignancy classification, we compared five strategies: randomly initialized ResNet50, Models Genesis, Med3D, a Foundation Model for Cancer Biomarkers, and a Strategic Warm-Start (ResNet50-SWS) approach pretrained using detection-derived candidate patches stratified by confidence. Performance was summarized using AUC with 95% confidence intervals and DeLong tests. Detection performance varied substantially by training dataset, with DLCS-trained models outperforming LUNA16-trained models on external NLST-3D evaluation (sensitivity at 2 false positives per scan: 0.72 vs. 0.64; p < 0.001). For malignancy classification, ResNet50-SWS achieved AUCs of 0.71 (DLCS), 0.90 (LUNA16), 0.81 (NLST-3D), and 0.80 (LUNA25), consistently matching or exceeding alternative pretraining strategies. These results demonstrate that dataset characteristics strongly influence lung cancer AI performance and highlight the need for transparent, multi-dataset benchmarking.

cs.CV

The Utility of the Virtual Imaging Trials Methodology for Objective Characterization of AI Systems and Training Data

Purpose: The credibility of Artificial Intelligence (AI) models for medical imaging continues to be a challenge, affected by the diversity of models, the data used to train the models, and applicability of their combination to produce reproducible results for new data. In this work, we aimed to explore whether emerging Virtual Imaging Trials (VIT) methodologies can provide an objective resource to approach this challenge. Approach: The study was conducted for the case example of COVID-19 diagnosis using clinical and virtual computed tomography (CT) and chest radiography (CXR) processed with convolutional neural networks. Multiple AI models were developed and tested using 3D ResNet-like and 2D EfficientNetv2 architectures across diverse datasets. Results: Model performance was evaluated using the area under the curve (AUC) and the DeLong method for AUC confidence intervals. The models trained on the most diverse datasets showed the highest external testing performance, with AUC values ranging from 0.73-0.76 for CT and 0.70-0.73 for CXR. Internal testing yielded higher AUC values (0.77-0.85 for CT and 0.77-1.0 for CXR), highlighting a substantial drop in performance during external validation, which underscores the importance of diverse and comprehensive training and testing data. Most notably, the VIT approach provided objective assessment of the utility of diverse models and datasets, while offering insight into the influence of dataset characteristics, patient factors, and imaging physics on AI efficacy. Conclusions: The VIT approach enhances model transparency and reliability, offering nuanced insights into the factors driving AI performance and bridging the gap between experimental and clinical settings.

eess.IV

Organ-Aware Attention Improves CT Triage and Classification

There is an urgent need for triage and classification of high-volume medical imaging modalities such as computed tomography (CT), which can improve patient care and mitigate radiologist burnout. Study-level CT triage requires calibrated predictions with localized evidence; however, off-the-shelf Vision Language Models (VLM) struggle with 3D anatomy, protocol shifts, and noisy report supervision. This study used the two largest publicly available chest CT datasets: CT-RATE and RADCHEST-CT (held-out external test set). Our carefully tuned supervised baseline (instantiated as a simple Global Average Pooling head) establishes a new supervised state of the art, surpassing all reported linear-probe VLMs. Building on this baseline, we present ORACLE-CT, an encoder-agnostic, organ-aware head that pairs Organ-Masked Attention (mask-restricted, per-organ pooling that yields spatial evidence) with Organ-Scalar Fusion (lightweight fusion of normalized volume and mean-HU cues). In the chest setting, ORACLE-CT masked attention model achieves AUROC 0.86 on CT-RATE; in the abdomen setting, on MERLIN (30 findings), our supervised baseline exceeds a reproduced zero-shot VLM baseline obtained by running publicly released weights through our pipeline, and adding masked attention plus scalar fusion further improves performance to AUROC 0.85. Together, these results deliver state-of-the-art supervised classification performance across both chest and abdomen CT under a unified evaluation protocol. The source code is available at https://github.com/lavsendahal/oracle-ct.

cs.CV

Large Intestine 3D Shape Refinement Using Point Diffusion Models for Digital Phantom Generation

Accurate 3D modeling of human organs is critical for constructing digital phantoms in virtual imaging trials. However, organs such as the large intestine remain particularly challenging due to their complex geometry and shape variability. We propose CLAP, a novel Conditional LAtent Point-diffusion model that combines geometric deep learning with denoising diffusion models to enhance 3D representations of the large intestine. Given point clouds sampled from segmentation masks, we employ a hierarchical variational autoencoder to learn both global and local latent shape representations. Two conditional diffusion models operate within this latent space to refine the organ shape. A pretrained surface reconstruction model is then used to convert the refined point clouds into meshes. CLAP achieves substantial improvements in shape modeling accuracy, reducing Chamfer distance by 26% and Hausdorff distance by 36% relative to the initial suboptimal shapes. This approach offers a robust and extensible solution for high-fidelity organ modeling, with potential applicability to a wide range of anatomical structures.

cs.CV

Demographic Distribution Matching between real world and virtual phantom population

Virtual imaging trials (VITs) offer scalable and cost-effective tools for evaluating imaging systems and protocols. However, their translational impact depends on rigorous comparability between virtual and real-world populations. This study introduces DISTINCT (Distributional Subsampling for Covariate-Targeted Alignment), a statistical framework for selecting demographically aligned subsamples from large clinical datasets to support robust comparisons with virtual cohorts. We applied DISTINCT to the National Lung Screening Trial (NLST) and a companion virtual trial dataset (VLST). The algorithm jointly aligned typical continuous (age, BMI) and categorical (sex, race, ethnicity) variables by constructing multidimensional bins based on discretized covariates. For a given target size, DISTINCT samples individuals to match the joint demographic distribution of the reference population. We evaluated the demographic similarity between VLST and progressively larger NLST subsamples using Wasserstein and Kolmogorov-Smirnov (K-S) distances to identify the maximal subsample size with acceptable alignment. The algorithm identified a maximal aligned NLST subsample of 9,974 participants, preserving demographic similarity to the VLST population. Receiver operating characteristic (ROC) analysis using risk scores for lung cancer detection showed that area under the curve (AUC) estimates stabilized beyond 6,000 participants, confirming the sufficiency of aligned subsamples for virtual imaging trial evaluation. Stratified AUC analysis revealed substantial performance variation across demographic subgroups, reinforcing the importance of covariate alignment in comparative studies.

stat.AP

Virtual Lung Screening Trial (VLST): An In Silico Study Inspired by the National Lung Screening Trial for Lung Cancer Detection

Clinical imaging trials play a crucial role in advancing medical innovation but are often costly, inefficient, and ethically constrained. Virtual Imaging Trials (VITs) present a solution by simulating clinical trial components in a controlled, risk-free environment. The Virtual Lung Screening Trial (VLST), an in silico study inspired by the National Lung Screening Trial (NLST), illustrates the potential of VITs to expedite clinical trials, minimize risks to participants, and promote optimal use of imaging technologies in healthcare. This study aimed to show that a virtual imaging trial platform could investigate some key elements of a major clinical trial, specifically the NLST, which compared Computed tomography (CT) and chest radiography (CXR) for lung cancer screening. With simulated cancerous lung nodules, a virtual patient cohort of 294 subjects was created using XCAT human models. Each virtual patient underwent both CT and CXR imaging, with deep learning models, the AI CT-Reader and AI CXR-Reader, acting as virtual readers to perform recall patients with suspicion of lung cancer. The primary outcome was the difference in diagnostic performance between CT and CXR, measured by the Area Under the Curve (AUC). The AI CT-Reader showed superior diagnostic accuracy, achieving an AUC of 0.92 (95% CI: 0.90-0.95) compared to the AI CXR-Reader's AUC of 0.72 (95% CI: 0.67-0.77). Furthermore, at the same 94% CT sensitivity reported by the NLST, the VLST specificity of 73% was similar to the NLST specificity of 73.4%. This CT performance highlights the potential of VITs to replicate certain aspects of clinical trials effectively, paving the way toward a safe and efficient method for advancing imaging-based diagnostics.

eess.IV

XCAT-3.0: A Comprehensive Library of Personalized Digital Twins Derived from CT Scans

Virtual Imaging Trials (VIT) offer a cost-effective and scalable approach for evaluating medical imaging technologies. Computational phantoms, which mimic real patient anatomy and physiology, play a central role in VITs. However, the current libraries of computational phantoms face limitations, particularly in terms of sample size and diversity. Insufficient representation of the population hampers accurate assessment of imaging technologies across different patient groups. Traditionally, the more realistic computational phantoms were created by manual segmentation, which is a laborious and time-consuming task, impeding the expansion of phantom libraries. This study presents a framework for creating realistic computational phantoms using a suite of automatic segmentation models and performing three forms of automated quality control on the segmented organ masks. The result is the release of over 2500 new computational phantoms, so-named XCAT3.0 after the ubiquitous XCAT computational construct. This new formation embodies 140 structures and represents a comprehensive approach to detailed anatomical modeling. The developed computational phantoms are formatted in both voxelized and surface mesh formats. The framework is combined with an in-house CT scanner simulator to produce realistic CT images. The framework has the potential to advance virtual imaging trials, facilitating comprehensive and reliable evaluations of medical imaging technologies. Phantoms may be requested at https://cvit.duke.edu/resources/. Code, model weights, and sample CT images are available at https://xcat-3.github.io/.

eess.IV

Uncertainty Estimation in Deep 2D Echocardiography Segmentation

2D echocardiography is the most common imaging modality for cardiovascular diseases. The portability and relatively low-cost nature of Ultrasound (US) enable the US devices needed for performing echocardiography to be made widely available. However, acquiring and interpreting cardiac US images is operator dependent, limiting its use to only places where experts are present. Recently, Deep Learning (DL) has been used in 2D echocardiography for automated view classification, and structure and function assessment. Although these recent works show promise in developing computer-guided acquisition and automated interpretation of echocardiograms, most of these methods do not model and estimate uncertainty which can be important when testing on data coming from a distribution further away from that of the training data. Uncertainty estimates can be beneficial both during the image acquisition phase (by providing real-time feedback to the operator on acquired image's quality), and during automated measurement and interpretation. The performance of uncertainty models and quantification metric may depend on the prediction task and the models being compared. Hence, to gain insight of uncertainty modelling for left ventricular segmentation from US images, we compare three ensembling based uncertainty models quantified using four different metrics (one newly proposed) on state-of-the-art baseline networks using two publicly available echocardiogram datasets. We further demonstrate how uncertainty estimation can be used to automatically reject poor quality images and improve state-of-the-art segmentation results.

cs.CV

DSNet: Automatic Dermoscopic Skin Lesion Segmentation

Automatic segmentation of skin lesion is considered a crucial step in Computer Aided Diagnosis (CAD) for melanoma diagnosis. Despite its significance, skin lesion segmentation remains a challenging task due to their diverse color, texture, and indistinguishable boundaries and forms an open problem. Through this study, we present a new and automatic semantic segmentation network for robust skin lesion segmentation named Dermoscopic Skin Network (DSNet). In order to reduce the number of parameters to make the network lightweight, we used depth-wise separable convolution in lieu of standard convolution to project the learned discriminating features onto the pixel space at different stages of the encoder. Additionally, we implemented U-Net and Fully Convolutional Network (FCN8s) to compare against the proposed DSNet. We evaluate our proposed model on two publicly available datasets, namely ISIC-2017 and PH2. The obtained mean Intersection over Union (mIoU) is 77.5 % and 87.0 % respectively for ISIC-2017 and PH2 datasets which outperformed the ISIC-2017 challenge winner by 1.0 % with respect to mIoU. Our proposed network also outperformed U-Net and FCN8s respectively by 3.6 % and 6.8 % with respect to mIoU on the ISIC-2017 dataset. Our network for skin lesion segmentation outperforms other methods and can provide better segmented masks on two different test datasets which can lead to better performance in melanoma detection. Our trained model along with the source code and predicted masks are made publicly available.

eess.IV

Automatic Cobb Angle Detection using Vertebra Detector and Vertebra Corners Regression

Correct evaluation and treatment of Scoliosis require accurate estimation of spinal curvature. Current gold standard is to manually estimate Cobb Angles in spinal X-ray images which is time consuming and has high inter-rater variability. We propose an automatic method with a novel framework that first detects vertebrae as objects followed by a landmark detector that estimates the 4 landmark corners of each vertebra separately. Cobb Angles are calculated using the slope of each vertebra obtained from the predicted landmarks. For inference on test data, we perform pre and post processings that include cropping, outlier rejection and smoothing of the predicted landmarks. The results were assessed in AASCE MICCAI challenge 2019 which showed a promise with a SMAPE score of 25.69 on the challenge test set.

cs.CV

Brain Tissue Segmentation Using NeuroNet With Different Pre-processing Techniques

Automatic segmentation of brain Magnetic Resonance Imaging (MRI) images is one of the vital steps for quantitative analysis of brain for further inspection. In this paper, NeuroNet has been adopted to segment the brain tissues (white matter (WM), grey matter (GM) and cerebrospinal fluid (CSF)) which uses Residual Network (ResNet) in encoder and Fully Convolution Network (FCN) in the decoder. To achieve the best performance, various hyper-parameters have been tuned, while, network parameters (kernel and bias) were initialized using the NeuroNet pre-trained model. Different pre-processing pipelines have also been introduced to get a robust trained model. The model has been trained and tested on IBSR18 data-set. To validate the research outcome, performance was measured quantitatively using Dice Similarity Coefficient (DSC) and is reported on average as 0.84 for CSF, 0.94 for GM, and 0.94 for WM. The outcome of the research indicates that for the IBSR18 data-set, pre-processing and proper tuning of hyper-parameters for NeuroNet model have improvement in DSC for the brain tissue segmentation.

cs.CV