Publications and source records attributed to Lennart Verhagen.

6 recordsLinked to original sources

ITRUSST Consensus on Biophysical Safety for Transcranial Ultrasound Stimulation

Transcranial ultrasound stimulation (TUS) is an emerging technology for non-invasive brain stimulation. The International Transcranial Ultrasonic Stimulation Safety and Standards consortium (ITRUSST) has established consensus on considerations for nonsignificant biophysical risk of TUS, drawing upon the literature and established regulations for biomedical devices. Here, we assume the application of TUS to individuals without contraindications, compromised thermoregulation, vascular vulnerabilities, or administered ultrasound contrast agents. In this context, we present a concise yet comprehensive set of levels for nonsignificant risks of TUS application. For mechanical effects, it is non-significant risk if the mechanical index (MI) or the mechanical index for transcranial application (MItc) does not exceed 1.9. For thermal effects, it is non-significant risk if any of the following three levels are met: the peak temperature rise does not exceed 2°C or the peak absolute temperature does not exceed 39°C, assuming a baseline temperature of 37°C, the thermal dose does not exceed 2 CEM43 in brain tissue, 16 CEM43 in bone tissue, and 21 CEM43 in skin tissue, or specific values of the thermal index (TI) for a given exposure time. This report reflects a consensus expert opinion and can inform, but not replace, regulatory guidelines or official international standards. Similarly, this consensus can inform, but not replace, ethical evaluation, which weighs the total burden, risks, and benefits of the proposed action. The stated levels are not safety limits per se, and further data is needed to establish the threshold for significant risk. We review literature relevant to our considerations and discuss limitations and future developments of our approach.

physics.bio-ph↗

A Practical Guide to Transcranial Ultrasonic Stimulation from the IFCN-endorsed ITRUSST Consortium

Low-intensity Transcranial Ultrasonic Stimulation (TUS) is a non-invasive brain stimulation technique enabling cortical and deep brain targeting with unprecedented spatial accuracy. Given the high rate of adoption by new users with varying levels of expertise and interdisciplinary backgrounds, practical guidelines are needed to ensure state-of-the-art TUS application and reproducible outcomes. Therefore, the International Transcranial Ultrasonic Stimulation Safety and Standards (ITRUSST) consortium has formed a subcommittee, endorsed by the International Federation of Clinical Neurophysiology (IFCN), to develop recommendations for best practice in TUS applications in humans. The practical guide presented here provides a brief introduction into ultrasound physics and sonication parameters. It explains the requirements of TUS lab equipment and transducer selection and discusses experimental design and procedures alongside potential confounds and control conditions. Finally, the guide elaborates on essential steps of application planning for stimulation safety and efficacy, as well as considerations when combining TUS with neuroimaging, electrophysiology, or other brain stimulation techniques. We hope that this practical guide to TUS will assist both novice and experienced users in planning and conducting high-quality studies and provide a solid foundation for further advancements in this promising field.

physics.med-ph↗

Biophysical effects and neuromodulatory dose of transcranial ultrasonic stimulation

Transcranial ultrasonic stimulation (TUS) has the potential to usher in a new era for human neuroscience by allowing spatially precise and high-resolution non-invasive targeting of both deep and superficial brain regions. Currently, fundamental research on the mechanisms of interaction between ultrasound and neural tissues is progressing in parallel with application-focused research. However, a major hurdle in the wider use of TUS is the selection of optimal parameters to enable safe and effective neuromodulation in humans. In this paper, we will discuss the major factors that determine both the safety and efficacy of TUS. We will discuss the thermal and mechanical biophysical effects of ultrasound, which underlie its biological effects, in the context of their relationships with tunable parameters. Based on this knowledge of biophysical effects, and drawing on concepts from radiotherapy, we propose a framework for conceptualising TUS dose.

physics.bio-ph↗

The relationship between parameters and effects in transcranial ultrasonic stimulation

Transcranial ultrasonic stimulation (TUS) is rapidly gaining traction for non-invasive human neuromodulation, with a pressing need to establish protocols that maximise neuromodulatory efficacy. In this review, we aggregate and examine empirical evidence for the relationship between tunable TUS parameters and in vitro and in vivo outcomes. Based on this multiscale approach, TUS researchers can make better informed decisions about optimal parameter settings. Importantly, we also discuss the challenges involved in extrapolating results from prior empirical work to future interventions, including the translation of protocols between models and the complex interaction between TUS protocols and the brain. A synthesis of the empirical evidence suggests that larger effects will be observed at lower frequencies within the sub-MHz range, higher intensities and pressures than commonly administered thus far, and longer pulses and pulse train durations. Nevertheless, we emphasise the need for cautious interpretation of empirical data from different experimental paradigms when basing protocols on prior work as we advance towards refined TUS parameters for human neuromodulation.

physics.bio-ph↗

ITRUSST Consensus on Standardised Reporting for Transcranial Ultrasound Stimulation

As transcranial ultrasound stimulation (TUS) advances as a precise, non-invasive neuromodulatory method, there is a need for consistent reporting standards to enable comparison and reproducibility across studies. To this end, the International Transcranial Ultrasonic Stimulation Safety and Standards Consortium (ITRUSST) formed a subcommittee of experts across several domains to review and suggest standardised reporting parameters for low intensity TUS, resulting in the guide presented here. The scope of the guide is limited to reporting the ultrasound aspects of a study. The guide and supplementary material provide a simple checklist covering the reporting of: (1) the transducer and drive system, (2) the drive system settings, (3) the free field acoustic parameters, (4) the pulse timing parameters, (5) \emph{in situ} estimates of exposure parameters in the brain, and (6) intensity parameters. Detailed explanations for each of the parameters, including discussions on assumptions, measurements, and calculations, are also provided.

physics.med-ph↗

Pseudo-CTs from T1-weighted MRI for planning of low-intensity transcranial focused ultrasound neuromodulation: an open-source tool

Background: Individual skull models of bone density and geometry are important when planning the expected transcranial ultrasound acoustic field and estimating mechanical and thermal safety in low-intensity transcranial ultrasound stimulation (TUS) studies. Computed tomography (CT) images have typically been used to estimate skull acoustic properties. However, obtaining CT images in research participants may be prohibitive due to exposure to ionising radiation and limited access to CT scanners within research groups. Objective: We present a validated open-source tool for researchers to obtain individual skull estimates from T1-weighted MR images, for use in acoustic simulations. Methods: We refined a previously trained and validated 3D convolutional neural network (CNN) to generate 100 keV pseudo-CTs. The network was pretrained on 110 individuals and refined and tested on a database of 37 healthy control individuals. We compared simulations based on reference CTs to simulations based on our pseudo-CTs and binary skull masks, a common alternative in the absence of CT. Results: Compared with reference CTs, our CNN produced pseudo-CTs with a mean absolute error of 109.8 +/- 13.0 HU across the whole head and 319.3 +/- 31.9 HU in the skull. In acoustic simulations, the focal pressure was statistically equivalent for simulations based on reference CT and pseudo-CT (0.48 +/- 0.04 MPa and 0.50 +/- 0.04 MPa respectively) but not for binary skull masks (0.28 +/- 0.05 MPa). Conclusions: We show that our network can produce pseudo-CT comparable to reference CTs in healthy individuals, and that these can be used in acoustic simulations.

physics.med-ph↗