SearcharxivSearch

arXiv subjects

Leonardo Stiaccini

Publications and source records attributed to Leonardo Stiaccini.

9 recordsLinked to original sources

Design and Performance of the Upgraded Prototype Schwarzschild-Couder Telescope Camera Module

The Cherenkov Telescope Array Observatory (CTAO) is a ground-based observatory that will improve upon the sensitivities of the current generation of very-high-energy gamma-ray instruments. The Schwarzschild-Couder Telescope (SCT) is a dual-mirror candidate design for a CTAO Medium-Sized Telescope (MST). The prototype Schwarzschild-Couder Telescope (pSCT) was inaugurated in 2019 at Fred Lawrence Whipple Observatory (FLWO) in Arizona and observed significant gamma-ray emission from the Crab Nebula with a partially populated camera. The pSCT camera is currently being upgraded to fully instrument the focal plane with 11,328 silicon photomultiplier (SiPM) pixels split between 177 camera modules. Additionally, the modules will feature upgraded electronics designed to reduce electronics crosstalk and noise. A module calibration procedure has been developed using a preproduction test module. Following this calibration procedure, performance testing shows that the upgrade module has low noise, minimal electronics crosstalk, and excellent charge resolution. After calibration and optimization, the 177 production modules will be installed in the pSCT camera for commissioning. This will be followed by observations of known VHE gamma-ray sources for camera performance validation.

astro-ph.IM

A Wearable Wireless Magnetic Eye-Tracker, in-vitro and in-vivo Tests

A wireless, wearable magnetic eye tracker is described and characterized. The proposed instrumentation enables simultaneous evaluation of eye and head angular displacements. Such a system can be used to determine the absolute gaze direction as well as to analyze spontaneous eye re-orientation in response to stimuli consisting in head rotations. The latter feature has implications to analyze the vestibulo-ocular reflex and constitutes an interesting opportunity to develop medical (oto-neurological) diagnostics. Details of data analysis are reported together with some results obtained in-vivo or with simple mechanical simulators that enable measurements under controlled conditions.

physics.med-ph

Design and Performance of the Prototype Schwarzschild-Couder Telescope Camera

The prototype Schwarzschild-Couder Telescope (pSCT) is a candidate for a medium-sized telescope in the Cherenkov Telescope Array. The pSCT is based on a novel dual mirror optics design which reduces the plate scale and allows for the use of silicon photomultipliers as photodetectors. The prototype pSCT camera currently has only the central sector instrumented with 25 camera modules (1600 pixels), providing a 2.68$^{\circ}$ field of view (FoV). The camera electronics are based on custom TARGET (TeV array readout with GSa/s sampling and event trigger) application specific integrated circuits. Field programmable gate arrays sample incoming signals at a gigasample per second. A single backplane provides camera-wide triggers. An upgrade of the pSCT camera is in progress, which will fully populate the focal plane. This will increase the number of pixels to 11,328, the number of backplanes to 9, and the FoV to 8.04$^{\circ}$. Here we give a detailed description of the pSCT camera, including the basic concept, mechanical design, detectors, electronics, current status and first light.

astro-ph.IM

An innovative eye-tracker. Main features and demonstrative tests

We present a set of results obtained with an innovative eye-tracker based on magnetic dipole localization by means of an array of magnetoresistive sensors. The system tracks both head and eye movements with a high rate (100-200 Sa/s) and in real time. A simple setup is arranged to simulate head and eye motions and to test the tracker performance under realistic conditions. Multimedia material is provided to substantiate and exemplify the results. A comparison with other available technologies for eye tracking is drawn, discussing advantages (e.g. precision) and disadvantages (e.g. invasivity) of the diverse approaches, the presented method standing out for low cost, robustness and relatively low invasivity.

physics.med-ph

Ferromagnetic contamination of Ultra-Low-Field-NMR sample containers. Quantification of the problem and possible solutions

The presence of a weak remanence in Ultra-Low-Field (ULF) NMR sample containers is investigated on the basis of proton precession. The high-sensitivity magnetometer used for the NMR detection, enables simultaneously the measurement of the static field produced in the sample proximity by ferromagnetic contaminants. The presence of the latter is studied by high resolution chemical analyses of the surface, based on X-ray fluorescence spectroscopy and secondary ions mass spectroscopy. Methodologies to reduce the contamination are explored and characterized. This study is of relevance in any ULF-NMR experiment, as in the ULF regime spurious ferromagnetism becomes easily a dominant cause of artefacts.

physics.ins-det

Fast switching coil system for sample premagnetization in an unshielded ultra-low-field Nuclear Magnetic Resonance experiment

We present a system developed to premagnetize liquid samples in an ultra-low-field Nuclear Magnetic Resonance (NMR) experiment. Liquid samples of a few milliliter are exposed to a magnetic field of about 70~mT, which is abruptely switched off, so to leave a transverse microtesla field where nuclei start precessing. An accurate characterization of the transients and intermediate field level enables a reliable operation of the detection system, which is based on an optical magnetometer.

physics.ins-det

Spurious Ferromagnetic Remanence Detected by Hybrid Magnetometer

Nuclear magnetic resonance detection in ultra low field regime enables the measurement of different components of a spurious remanence in the polymeric material constituting the sample container. A differential atomic magnetometer detects simultaneously the static field generated by the container and the time-dependent signal from the precessing nuclei. The nuclear precession responds with frequency shifts and decay rate variations to the container magnetization. Two components of the latter act independently on the atomic sensor and on the nuclear sample. A model of the measured signal allows a detailed interpretation, on the basis of the interaction geometry.

physics.ins-det

A low noise modular current source for stable magnetic field control

A low cost, stable, programmable, unipolar current source is described. The circuit is designed in view of a modular arrangement, suitable for applications where several DC sources must be controlled at once. A hybrid switching/linear design helps in improving the stability and in reducing the power dissipation and cross-talking. Multiple units can be supplied by a single DC power supply, while allowing for a variety of maximal current values and compliance voltages at the outputs. The circuit is analogically controlled by an unipolar voltage, enabling current programmability and control through commercial digital-to-analogue conversion cards.

physics.ins-det

A fast pneumatic sample-shuttle with attenuated shocks

We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free induction decay in ultra-low-field and zero-field NMR experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a 'cold' environment.

physics.ins-det