SearcharxivSearch

arXiv subjects

Liang Min

Publications and source records attributed to Liang Min.

2 recordsLinked to original sources

Decentralized and Coordinated Vf Control for Islanded Microgrids Considering DER Inadequacy and Demand Control

This paper proposes a decentralized and coordinated voltage and frequency (Vf) control framework for islanded microgrids, with full consideration of the limited capacity of distributed energy resources (DERs) and Vf dependent load. First, the concept of DER inadequacy is illustrated with the challenges it poses. Then, a decentralized and coordinated control framework is proposed to regulate the output of inverter based generations and reallocate limited DER capacity for Vf control. The control framework is composed of a power regulator and a Vf regulator, which generates the supplementary signals for the primary controller. The power regulator regulates the output of grid forming inverters according to the real time capacity constraints of DERs, while the Vf regulator improves the Vf deviation by leveraging the load sensitivity to Vf. Next, the static feasibility and small signal stability of the proposed method are rigorously proven through mathematical formulation and eigenvalue analysis. Finally, a MATLAB Simulink simulation demonstrates the functionalities of the control framework. A few goals are fulfilled within the decentralized and coordinated framework, such as making the best use of limited DERs capacity, enhancing the DC side stability of inverter based generations, and reducing involuntary load shedding.

eess.SY

Power Distribution System Synchrophasors with Non-Gaussian Errors: Real-World Measurements and Analysis

This letter studies the synchrophasor measurement error of electric power distribution systems with on-line and off-line measurements using graphical and numerical tests. It demonstrates that the synchrophasor measurement error follows a non-Gaussian distribution instead of the traditionally-assumed Gaussian distribution. It suggests the need to use non-Gaussian or Gaussian mixture models to represent the synchrophasor measurement error. These models are more realistic to accurately represent the error than the traditional Gaussian model. The measurements and underlying analysis will be helpful for the understanding of distribution system measurement characteristics, and also for the modeling and simulation of distribution system applications.

eess.SP