SearcharxivSearch

arXiv subjects

Lili Ma

Publications and source records attributed to Lili Ma.

13 recordsLinked to original sources

GloPath: An Entity-Centric Foundation Model for Glomerular Lesion Assessment and Clinicopathological Insights

Glomerular pathology is central to the diagnosis and prognosis of renal diseases, yet the heterogeneity of glomerular morphology and fine-grained lesion patterns remain challenging for current AI approaches. We present GloPath, an entity-centric foundation model trained on over one million glomeruli extracted from 14,049 renal biopsy specimens using multi-scale and multi-view self-supervised learning. GloPath addresses two major challenges in nephropathology: glomerular lesion assessment and clinicopathological insights discovery. For lesion assessment, GloPath was benchmarked across three independent cohorts on 52 tasks, including lesion recognition, grading, few-shot classification, and cross-modality diagnosis-outperforming state-of-the-art methods in 42 tasks (80.8%). In the large-scale real-world study, it achieved an ROC-AUC of 91.51% for lesion recognition, demonstrating strong robustness in routine clinical settings. For clinicopathological insights, GloPath systematically revealed statistically significant associations between glomerular morphological parameters and clinical indicators across 224 morphology-clinical variable pairs, demonstrating its capacity to connect tissue-level pathology with patient-level outcomes. Together, these results position GloPath as a scalable and interpretable platform for glomerular lesion assessment and clinicopathological discovery, representing a step toward clinically translatable AI in renal pathology.

cs.CV

Convolutional Feature Enhancement and Attention Fusion BiFPN for Ship Detection in SAR Images

Synthetic Aperture Radar (SAR) enables submeter-resolution imaging and all-weather monitoring via active microwave and advanced signal processing. Currently, SAR has found extensive applications in critical maritime domains such as ship detection. However, SAR ship detection faces several challenges, including significant scale variations among ships, the presence of small offshore vessels mixed with noise, and complex backgrounds for large nearshore ships. To address these issues, this paper proposes a novel feature enhancement and fusion framework named C-AFBiFPN. C-AFBiFPN constructs a Convolutional Feature Enhancement (CFE) module following the backbone network, aiming to enrich feature representation and enhance the ability to capture and represent local details and contextual information. Furthermore, C-AFBiFPN innovatively integrates BiFormer attention within the fusion strategy of BiFPN, creating the AFBiFPN network. AFBiFPN improves the global modeling capability of cross-scale feature fusion and can adaptively focus on critical feature regions. The experimental results on SAR Ship Detection Dataset (SSDD) indicate that the proposed approach substantially enhances detection accuracy for small targets, robustness against occlusions, and adaptability to multi-scale features.

cs.CV

Frictional Adhesive Contact of Multiferroic Coatings Based on the Hybrid Element Method

We study the frictional adhesive contact of a rigid insulating sphere sliding past a multiferroic coating deposed onto a rigid substrate, based on the hybrid element method (HEM). The adhesion behavior is described based on the Maugis-Dugdale (MD) model. The adhesion-driven conjugate gradient method (AD-CGM) is employed to calculate the distribution of unknown pressures, while the discrete convolution-fast Fourier transform (DC-FFT) is utilized to compute the deformations, surface electric and magnetic potentials as well as the subsurface stresses, electric displacements, and magnetic inductions. We found that the coating thickness affect the contact stiffness and the interplay between friction and adhesion. More importantly, friction and gap-dependent MD adhesion affects elastic, electric, and magnetic behavior of the interface, breaking the symmetry between leading and trailing edges behaviors in all the investigated fields. Indeed, increasing the friction coefficient, the contact shape is no longer circular, the pressure distribution shifts towards the leading edge, the electric/magnetic surface potentials distributions sharpen at the leading edge, and the subsurface stress fields concentrates at the trailing edges.

cond-mat.soft

Efficient Convolutional Neural Network for FMCW Radar Based Hand Gesture Recognition

FMCW radar could detect object's range, speed and Angleof-Arrival, advantages are robust to bad weather, good range resolution, and good speed resolution. In this paper, we consider the FMCW radar as a novel interacting interface on laptop. We merge sequences of object's range, speed, azimuth information into single input, then feed to a convolution neural network to learn spatial and temporal patterns. Our model achieved 96% accuracy on test set and real-time test.

cs.HC

Representations and $T$*-extensions of hom-Jordan-Lie algebras

The purpose of this paper is to study representations and $T$*-extensions of hom-Jordan-Lie algebras. In particular, adjoint representations, trivial representations, deformations and many properties of $T$*-extensions of hom-Jordan-Lie algebras are studied in detail. Derivations and central extensions of hom-Jordan-Lie algebras are also discussed as an application.

math.RA

Detecting Structure of Complex Network by Quantum Bosonic Dynamics

We introduce a non-interacting boson model to investigate topological structure of complex networks in the present paper. By exactly solving this model, we show that it provides a powerful analytical tool in uncovering the important properties of real-world networks. We find that the ground state degeneracy of this model is equal to the number of connected components in the network and the square of coefficients in the expansion of ground state gives the averaged time for a random walker spending at each node in the infinite time limit. Furthermore, the first excited state appears always on its largest connected component. To show usefulness of this approach in practice, we carry on also numerical simulations on some concrete complex networks. Our results are completely consistent with the previous conclusions derived by graph theory methods.

physics.soc-ph

Blind Detection and Compensation of Camera Lens Geometric Distortions

This paper presents a blind detection and compensation technique for camera lens geometric distortions. The lens distortion introduces higher-order correlations in the frequency domain and in turn it can be detected using higher-order spectral analysis tools without assuming any specific calibration target. The existing blind lens distortion removal method only considered a single-coefficient radial distortion model. In this paper, two coefficients are considered to model approximately the geometric distortion. All the models considered have analytical closed-form inverse formulae.

cs.CV

A Family of Simplified Geometric Distortion Models for Camera Calibration

The commonly used radial distortion model for camera calibration is in fact an assumption or a restriction. In practice, camera distortion could happen in a general geometrical manner that is not limited to the radial sense. This paper proposes a simplified geometrical distortion modeling method by using two different radial distortion functions in the two image axes. A family of simplified geometric distortion models is proposed, which are either simple polynomials or the rational functions of polynomials. Analytical geometric undistortion is possible using two of the distortion functions discussed in this paper and their performance can be improved by applying a piecewise fitting idea. Our experimental results show that the geometrical distortion models always perform better than their radial distortion counterparts. Furthermore, the proposed geometric modeling method is more appropriate for cameras whose distortion is not perfectly radially symmetric around the center of distortion.

cs.CV

Camera Calibration: a USU Implementation

The task of camera calibration is to estimate the intrinsic and extrinsic parameters of a camera model. Though there are some restricted techniques to infer the 3-D information about the scene from uncalibrated cameras, effective camera calibration procedures will open up the possibility of using a wide range of existing algorithms for 3-D reconstruction and recognition. The applications of camera calibration include vision-based metrology, robust visual platooning and visual docking of mobile robots where the depth information is important.

cs.CV

An Analytical Piecewise Radial Distortion Model for Precision Camera Calibration

The common approach to radial distortion is by the means of polynomial approximation, which introduces distortion-specific parameters into the camera model and requires estimation of these distortion parameters. The task of estimating radial distortion is to find a radial distortion model that allows easy undistortion as well as satisfactory accuracy. This paper presents a new piecewise radial distortion model with easy analytical undistortion formula. The motivation for seeking a piecewise radial distortion model is that, when a camera is resulted in a low quality during manufacturing, the nonlinear radial distortion can be complex. Using low order polynomials to approximate the radial distortion might not be precise enough. On the other hand, higher order polynomials suffer from the inverse problem. With the new piecewise radial distortion function, more flexibility is obtained and the radial undistortion can be performed analytically. Experimental results are presented to show that with this new piecewise radial distortion model, better performance is achieved than that using the single function. Furthermore, a comparable performance with the conventional polynomial model using 2 coefficients can also be accomplished.

cs.CV

Flexible Camera Calibration Using a New Analytical Radial Undistortion Formula with Application to Mobile Robot Localization

Most algorithms in 3D computer vision rely on the pinhole camera model because of its simplicity, whereas virtually all imaging devices introduce certain amount of nonlinear distortion, where the radial distortion is the most severe part. Common approach to radial distortion is by the means of polynomial approximation, which introduces distortion-specific parameters into the camera model and requires estimation of these distortion parameters. The task of estimating radial distortion is to find a radial distortion model that allows easy undistortion as well as satisfactory accuracy. This paper presents a new radial distortion model with an easy analytical undistortion formula, which also belongs to the polynomial approximation category. Experimental results are presented to show that with this radial distortion model, satisfactory accuracy is achieved. An application of the new radial distortion model is non-iterative yellow line alignment with a calibrated camera on ODIS, a robot built in our CSOIS.

cs.CV

A New Analytical Radial Distortion Model for Camera Calibration

Common approach to radial distortion is by the means of polynomial approximation, which introduces distortion-specific parameters into the camera model and requires estimation of these distortion parameters. The task of estimating radial distortion is to find a radial distortion model that allows easy undistortion as well as satisfactory accuracy. This paper presents a new radial distortion model with an easy analytical undistortion formula, which also belongs to the polynomial approximation category. Experimental results are presented to show that with this radial distortion model, satisfactory accuracy is achieved.

cs.CV

Rational Radial Distortion Models with Analytical Undistortion Formulae

The common approach to radial distortion is by the means of polynomial approximation, which introduces distortion-specific parameters into the camera model and requires estimation of these distortion parameters. The task of estimating radial distortion is to find a radial distortion model that allows easy undistortion as well as satisfactory accuracy. This paper presents a new class of rational radial distortion models with easy analytical undistortion formulae. Experimental results are presented to show that with this class of rational radial distortion models, satisfactory and comparable accuracy is achieved.

cs.CV