Accurate myocardial T1 mapping at 5T using an improved MOLLI method: A validation study

Background: Accurate myocardial T1 mapping at 5T remains a technical challenge due to field inhomogeneity and prolonged T1 values. The aim of this study is to develop an accurate and clinically applicable myocardial T1 mapping technique for 5T magnetic resonance imaging (MRI) systems and validate its performance in a multicenter study. Methods: The proposed method is based on a 5-(3)-3 MOLLI sequence, dubbed combined-correction MOLLI (coMOLLI), which corrects for both inversion efficiency and readout-induced signal disturbances. Specifically, coMOLLI employs a gradient recalled echo (GRE) readout rather than the commonly used bSSFP readout. Its signal evolution is modeled to estimate T1 values, which incorporates both inversion efficiency and readout disturbances to improve fitting accuracy. To further enhance accuracy, the inversion pulse was redesigned under hardware constraints and the observed B0 and B1 variations over the heart at 5T, using adiabatic hyperbolic secant (HSn) and tangent/hyperbolic tangent (Tan/Tanh) pulses. The method was validated in phantom experiments, as well as in 21 healthy volunteers and 9 patients. Results: The optimized inversion pulse at 5T is the Tan/Tanh pulse with A = 10 kHz, K_s = 4, k = 22, and T_p = 8 ms. In phantom studies, coMOLLI showed high accuracy versus reference IR-FSE, yielding relative errors within 5% for all nine vials. In vivo studies, the average native myocardial T1 values across 21 healthy volunteers were 1468 +/- 48 ms, 1514 +/- 39 ms, and 1545 +/- 50 ms, and blood T1 values were 2182 +/- 132 ms, 2124 +/- 153 ms, and 2131 +/- 158 ms for apical, middle, and base slices, respectively. Conclusion: The coMOLLI method demonstrated high accuracy in phantom studies and feasibility in vivo studies. By adopting the widely used 5-(3)-3 MOLLI acquisition scheme, it shows potential for clinical cardiac imaging at 5T.

physics.med-ph

Myocardial T1 mapping at 5T using multi-inversion recovery real-time spoiled GRE

Objective: To develop an accurate myocardial T1 mapping technique at 5T using Look-Locker-based multiple inversion-recovery with the real-time spoiled gradient echo (GRE) acquisition. Approach: The proposed T1 mapping technique (mIR-rt) samples the recovery of inverted magnetization using the real-time GRE and the images captured during diastole are selected for T1 fitting. Multiple-inversion recoveries are employed to increase the sample size for accurate fitting. The T1 mapping method was validated using Bloch simulation, phantom studies, and in 16 healthy volunteers at 5T. Main results: In both simulation and phantom studies, the T1 values measured by mIR-rt closely approximate the reference T1 values, with errors less than 3%, while the conventional MOLLI sequence underestimates T1 values. The myocardial T1 values at 5T are 1553 +/- 52 ms, 1531 +/- 53 ms, and 1526 +/- 60 ms (mean +/- standard deviation) at the apex, middle, and base, respectively. The T1 values measured by MOLLI (1350 +/- 48 ms, 1349 +/- 47 ms, and 1354 +/- 45 ms at the apex, middle, and base) were significantly lower than those of mIR-rt with p<0.001 for all three layers. The mIR-rt sequence method used in our study provides high reproducibility, particularly in the middle slices, supporting its practical relevance for myocardial T1 mapping. Significance: The proposed method is feasible for myocardial T1 mapping at 5T and provides better accuracy than the conventional MOLLI sequence.

physics.med-ph