SearcharxivSearch

arXiv subjects

Lisa Blackberg

Publications and source records attributed to Lisa Blackberg.

2 recordsLinked to original sources

Novel Asymmetrical High-Resolution and High-Sensitivity Brain Dedicated PET system: Design optimization and performance evaluation

Objective. This study investigates the best achievable performance of a brain-dedicated PET system with high resolution and sensitivity by evaluating different detector configurations, while maintaining a practical system design suitable for dynamic brain Imaging. Approach. Monte Carlo simulations were performed to evaluate system sensitivity and image quality under various timing resolutions (200 ps, 100 ps and 50 ps). The PET scanner geometry was optimized for human head imaging, featuring an elliptical cylindrical configuration with a neck cut-out, and front/back panels to enhance sensitivity and line of response (LOR) sampling. Detector configurations using LYSO:Ce crystals of varying thicknesses (15 mm and 20 mm) and depth of interaction (DOI) levels were simulated. Sensitivity was calculated using a point-like 511 keV back-to-back gamma source simulated at multiple locations within the field of view (FOV). Image reconstruction was conducted using list mode Maximum Likelihood Expectation Maximization (MLEM), assessing both a Derenzo-type phantom and a voxelated digital brain phantom. Main results. A location-dependent sensitivity ranging from 35.04% to 13.59% was achieved using a 20 mm thick LYSO:Ce crystal. Spatial resolution ranged from 0.8 mm to 1.5 mm within the FOV without applying resolution recovery techniques, measured using the FWHM of reconstructed hot rods. Previous results using 15 mm crystals with three DOI levels showed sensitivity between 23.42% and 15.99%, confirming the performance benefits of increased detector thickness and DOI capability. Significance. This study demonstrates the potential of a practical, brain-optimized PET system to achieve superior resolution and sensitivity for brain imaging. The findings offer valuable insights into optimal detector configurations, supporting the development of next-generation high-performance brain PET technologies.

physics.med-ph

Maximum-Likelihood--Based Position Decoding of Laser Processed Converging Pixel CsI: Tl Detectors for High-Resolution SPECT

This study demonstrates the feasibility of a novel fabrication technique for high spatial resolution CsI: Tl scintillation detectors tailored for single photon emission computed tomography (SPECT) systems. Building upon our previously developed laser induced optical barrier (LIOB) method, which achieved high spatial resolution, excellent sensitivity, and 100% fabrication yield in CsI: Tl detectors, we extend this approach to a converging-pixel architecture. A CsI: Tl crystal array with converging pixels was designed and fabricated, featuring entrance-face pixels of 1.6x1.6 mm2 and photodetector side pixels of 2x2 mm2. To localize gamma-ray interactions, both the center of gravity (CoG) algorithm and a maximum-likelihood (ML) based decoding method were implemented. A custom built four axis motion platform was developed to deliver a finely collimated pencil beam at precisely controlled positions and angles across the array, enabling generation of a comprehensive dataset for prior knowledge and validation. The results demonstrate an energy resolution of 11.79+/-0.53% (collimated experiment) and a position localization accuracy of 1.00+/-0.42 mm (nearest neighbor interpolation), confirming that the proposed converging-pixel architecture, combined with statistical decoding algorithms, provides a promising path toward the development of high-performance SPECT detectors.

physics.med-ph