SearcharxivSearch

arXiv subjects

Lisha Peng

Publications and source records attributed to Lisha Peng.

7 recordsLinked to original sources

Design and Initial Test of the Weighing Unit for Tsinghua Tabletop Kibble Balance

This paper presents a customized weighing unit developed for the Tsinghua tabletop Kibble balance. The system is based on a flexure hinge mechanism sourced from a commercial weighing cell, with a major modification to the feedback control loop. The redesigned loop incorporates a capacitive displacement sensor for high-resolution position detection and a novel PID control strategy that ensures both fast dynamic response and high static stability. Initial characterization results demonstrate a repeatability better than 0.1 mg in air for 1 kg mass exchanges, validating the system's potential for high-accuracy mass metrology in Kibble balances.

physics.ins-det

Design and Verification of a New Current Source for Tsinghua Tabletop Kibble Balance

This paper presents an ultra-stable current source tailored for the one-mode, two-phase (OMTP) measurement scheme in Tsinghua tabletop Kibble balances. To achieve simultaneous high resolution and nA/A-level stability, a composite 'coarse-fine' control topology is proposed, utilizing a dual-DAC architecture and an active digital feedback loop. Experimental results show that the Allan deviation reaches 1 nA/A at an integration time of approximately 3 minutes, representing a tenfold improvement in measurement speed compared to commercial-source-based setups. Furthermore, the design offers a significant cost advantage, providing a satisfying option for high-precision, cost-effective mass realization.

physics.ins-det

Status of the Tsinghua Tabletop Kibble Balance

This paper reports on the status of the Tsinghua tabletop Kibble balance experiment, aiming to deliver a mass calibration instrument for kilogram realizations in accordance with the new International System of Units (SI). Major progress since 2024 in different aspects, i.e., electrical, magnetic, mechanical, and optical, is presented. The primary weighing and velocity measurement results are discussed.

physics.ins-det

Self-Error Correcting Method for Magnetic-Array-Type Current Sensors in Multi-Core Cable Applications

Data-driven methods enable online assessment of error states in magnetic-array-type current sensors, and long-term measurement stability can be enhanced through further self-error correction. However, when the magnetic-array-type current sensors are applied to multi-conductor systems such as multi-core cables, the time-varying correlations among conductor currents may degrade the performance of multi-latent-variable data-driven models for error evaluation. To address this issue, this paper proposes a robust self-error correcting method for magnetic-array-type current sensors even under significant variations in phase current correlations (e.g., large fluctuations in three-phase current imbalance). By incorporating phase current decoupling and principal component analysis (PCA), the correlation analysis of multi-latent variables (i.e., multi-conductor currents) is transformed into a single-latent-variable (corresponding to single phase current) modeling problem. Experimental results demonstrate that the proposed method effectively detects error drifts of magnetic field sensors as low as $2\times10^{-3}$ in relative error and $2\times10^{-3}$ rad in phase error. Accurate evaluation and correction of each magnetic field sensor's error drifts substantially eliminates the overall error drift in the magnetic-array-type current sensor, validating the feasibility and effectiveness of the proposed self-error correcting method.

physics.ins-det

Metering Error Estimation of Fast-Charging Stations Using Charging Data Analytics

Accurate electric energy metering (EEM) of fast charging stations (FCSs), serving as critical infrastructure in the electric vehicle (EV) industry and as significant carriers of vehicle-to-grid (V2G) technology, is the cornerstone for ensuring fair electric energy transactions. Traditional on-site verification methods, constrained by their high costs and low efficiency, struggle to keep pace with the rapid global expansion of FCSs. In response, this paper adopts a data-driven approach and proposes the measuring performance comparison (MPC) method. By utilizing the estimation value of state-of-charge (SOC) as a medium, MPC establishes comparison chains of EEM performance of multiple FCSs. Therefore, the estimation of EEM errors for FCSs with high efficiency is enabled. Moreover, this paper summarizes the interfering factors of estimation results and establishes corresponding error models and uncertainty models. Also, a method for discriminating whether there are EEM performance defects in FCSs is proposed. Finally, the feasibility of MPC method is validated, with results indicating that for FCSs with an accuracy grade of 2\%, the discriminative accuracy exceeds 95\%. The MPC provides a viable approach for the online monitoring of EEM performance for FCSs, laying a foundation for a fair and just electricity trading market.

eess.SP

Updates on the Tsinghua Tabletop Kibble Balance

With the adoption of the revised International System of Units (SI), the Kibble balance has become a pivotal instrument for mass calibrations against the Planck constant, $h$. One of the major focuses in the Kibble balance community is prioritizing experiments that achieve both high accuracy and compactness. The Tsinghua tabletop Kibble balance experiment seeks to develop a compact, high-precision, user-friendly, cost-effective, and open-hardware apparatus for mass realization, specifically within the kilogram range. This paper reports on the progress of the Tsinghua tabletop Kibble balance project over the past two years. Various aspects of the Tsinghua tabletop system, including electrical, magnetic, mechanical, and optical components, are summarized. Key achievements, such as the construction and characterization of the magnet system, determination of absolute gravitational acceleration, investigation of a capacitor-sensor-based weighing unit, and development of a high-precision current source, are presented to provide a comprehensive understanding of the experiment's status.

physics.ins-det

A Self-Healing Magnetic-Array-Type Current Sensor with Data-Driven Identification of Abnormal Magnetic Measurement Units

Magnetic-array-type current sensors have garnered increasing popularity owing to their notable advantages, including broadband functionality, a large dynamic range, cost-effectiveness, and compact dimensions. However, the susceptibility of the measurement error of one or more magnetic measurement units (MMUs) within the current sensor to drift significantly from the nominal value due to environmental factors poses a potential threat to the measurement accuracy of the current sensor. In light of the need to ensure sustained measurement accuracy over the long term, this paper proposes an innovative self-healing approach rooted in cyber-physics correlation. This approach aims to identify MMUs exhibiting abnormal measurement errors, allowing for the exclusive utilization of the remaining unaffected MMUs in the current measurement process. To achieve this, principal component analysis (PCA) is employed to discern the primary component, arising from fluctuations of the measured current, from the residual component, attributed to the drift in measurement error. This analysis is conducted by scrutinizing the measured data obtained from the MMUs. Subsequently, the squared prediction error (SPE) statistic (also called $Q$ statistic) is deployed to individually identify any MMU displaying abnormal behavior. The experimental results demonstrate the successful online identification of abnormal MMUs without the need for a standard magnetic field sensor. By eliminating the contributions from the identified abnormal MMUs, the accuracy of the current measurement is effectively preserved.

eess.SP