SearcharxivSearch

arXiv subjects

Lishuang Ma

Publications and source records attributed to Lishuang Ma.

2 recordsLinked to original sources

First experimental proof of PET imaging based on multi-anode MCP-PMTs with Cherenkov radiator-integrated window

Improving the coincidence time resolution (CTR) of time-of-flight positron emission tomography (TOF-PET) systems to achieve a higher signal-to-noise ratio (SNR) gain or even direct positron emission imaging (dPEI) is of paramount importance for many advanced new clinical applications of PET imaging. This places higher demands on the timing performance of all aspects of PET systems. One effective approach is to use microchannel plate photomultiplier tubes (MCP-PMTs) for prompt Cherenkov photon detection. In this study, we developed a dual-module Cherenkov PET imaging experimental platform, utilising our proprietary 8 * 8-anode Cherenkov radiator-integrated window MCP-PMTs in combination with custom-designed multi-channel electronics, and designed a specific calibration and correction method for the platform. Using this platform, a CTR of 103 ps FWHM was achieved. We overcame the limitations of single-anode detectors in previous experiments, significantly enhanced imaging efficiency and achieved module-level Cherenkov PET imaging for the first time. Imaging experiments involving radioactive sources and phantoms of various shapes and types were conducted, which preliminarily validated the feasibility and advancement of this imaging method. In addition, the effects of normalisation correction and the interaction probability between the gamma rays and the MCP on the images and experimental results were analysed and verified.

physics.ins-det

Single electron charge spectra of 8-inch high-collection-efficiency MCP-PMTs

The atomic layer deposition(ALD) coating lengthens the lifetime of microchannel plates(MCP), which are used as the electron amplifier of the photomultiplier tubes(PMT). In the Jinping Neutrino Experiment, the newly developed 8-inch MCP-PMT achieves high collection efficiency by coating with high secondary emission materials. The resulting single electron response(SER) charge distribution deviates from the Gaussian distribution in large charge regions.To understand the nature of the jumbo-charged SER, we designed a voltage-division experiment to quantify the dependence of the MCP gain on the energy of incident electrons. Combining the relationship with the Furman probabilistic model, we reproduced the SER charge spectra by an additional amplification stage on the input electrode of the first MCP. Our results favor a Gamma-Tweedie mixture to describe the SER charge spectra of the MCP-PMTs.

physics.ins-det