Searcharxiv⌕ Search

arXiv subjects

Ljiljana Morvaj

Publications and source records attributed to Ljiljana Morvaj.

5 recordsLinked to original sources

Construction and characterization of a muon trigger detector for the PSI muEDM experiment

We present the upgraded design, construction, and beam test results for the Muon Trigger Detector (MTD) developed for the muon Electric Dipole Moment (muEDM) experiment at the Paul Scherrer Institute (PSI) in Switzerland. This experiment aims to improve the sensitivity of the muon EDM measurement by more than three orders of magnitude beyond the current limit established by the BNL Muon $g-2$ experiment. Precise identification of storable incoming muons at the entrance of the storage solenoid is essential, as the MTD must rapidly trigger a pulsed magnetic kicker to confine muons in the central region of the solenoid, where a weakly focusing magnetic field is maintained. The MTD comprises two subsystems: a \SI{0.1}{mm}-thick plastic scintillator ``gate detector'' read out by four silicon photomultipliers (SiPMs), and a \SI{5}{mm}-thick CNC-machined plastic scintillator ``active aperture detector'' read out by six SiPMs. The geometry of the active aperture detector was optimized through acceptance studies to maximize both storage efficiency and background veto efficiency. Integrated fast electronics generate an LVTTL trigger signal under an anti-coincidence condition -- a muon detected in the gate but not in the aperture -- ensuring selective triggering of storable muon events for the EDM measurement. The system was tested at the PSI $π$E1 beamline using \SI{22.5}{MeV/\textit{c}} muons under scaled-down conditions to characterize detector response and trigger performance. A Geant4 simulation incorporating detailed optical photon transport and SiPM response modeling was developed and reproduces the measured event topologies with ${\sim}97\%$ agreement. These results validate the detector design and demonstrate the MTD's readiness for deployment in the full muEDM Phase-1 setup.

physics.ins-det↗

Letter Of Intent for a future $μ^+ \to \mathrm{e}^+ γ$ experiment at the High Intensity Muon Beam facility at PSI

Searches for charged lepton flavor violation in the muon sector stand out among the most sensitive and clean probes for physics beyond the Standard Model. Currently, $μ^+ \to \mathrm{e}^+ γ$ experiments provide the best constraints in this field for a wide range of models while, in the coming years, new experiments investigating the processes of $μ^+ \to \mathrm{e}^+ \mathrm{e}^+ \mathrm{e}^-$ and $μ\to \mathrm{e}$ conversion in the nuclear field are anticipated to reach comparable or higher sensitivities. The High-Intensity Muon Beam (HIMB) facility at PSI, which is expected to deliver muon beam intensities up to two orders of magnitude higher than the existing beam lines, offers a unique opportunity to significantly enhance the sensitivity of $μ^+ \to \mathrm{e}^+ γ$ searches. The discovery potential could be substantially boosted and a sensitivity comparable to that of all the other projects could be reestablished, which is essential for discriminating among competing new-physics scenarios should an observation occur in any of the channels. In this document, we express our interest in developing a $μ^+ \to \mathrm{e}^+ γ$ experimental program at HIMB, with the goal of improving, within the next decade, the sensitivity of the $μ^+ \to \mathrm{e}^+ γ$ search by more than one order of magnitude relative to the expected final result of the current leading experiment, MEG II. This effort would ensure that PSI retains its leadership in this field.

hep-ex↗

Radiation Testing of New Readout Electronics for the CMS ECAL Barrel

In preparation of the operation of the CMS electromagnetic calorimeter (ECAL) barrel at the High Luminosity Large Hadron Collider (HL-LHC) the entire on-detector electronics will be replaced. The new readout electronics comprises 12240 very front end (VFE), 2448 front end (FE) and low voltage regulator (LVR) cards arranged into readout towers (RTs) of five VFEs, one FE and one LVR card. The results of testing one RT of final prototype cards at CERNs CHARM mixed field facility and PSIs proton irradiation facility are presented. They demonstrate the proper functioning of the new electronics in the expected radiation conditions.

hep-ex↗

Higgs rare and exotic decays

Several recent searches for exotic and rare decays of the Standard Model Higgs boson with the ATLAS and CMS detectors are presented. The searches are performed on $\sqrt{s}$=13 TeV proton-proton collisions data collected at the LHC between 2015 and 2018. The topics covered include searches for the Higgs boson decays into two pseudoscalars, $H\rightarrow aa$, in three different final states, $2b2μ$, $4b$ and $2\mu2τ$, search for lepton-flavour violating Higgs decays, $H\rightarrow μτ/ eτ$, and search for a rare $H\rightarrow \ell\ell γ$ decay. ATLAS presents evidence for the $H\rightarrow \ell\ell γ$ rare decay, amounting to an observed significance of $3.2σ$.

hep-ex↗

Searches for new resonances decaying to W, Z and H bosons with the ATLAS and CMS detectors in 13 TeV proton-proton collisions at the LHC

Searches for high-mass resonances decaying to pairs of standard model bosons using ATLAS and CMS detectors are presented. The searches use 15 - 36 $\textrm{fb}^{-1}$ of proton-proton collision data collected at the centre-of-mass energy of 13 TeV at the LHC. Many different final states have been considered and the results are interpreted in a range of theories beyond the standard model of particle physics, most common being heavy vector triplet and warped extra dimensions.

hep-ex↗