Improved accuracy of the reference photon calibration standards in the network of gravitational-wave observatories during the O4 observing run

The global network of gravitational wave observatories uses systems known as Photon Calibrators to provide absolute calibration via laser radiation pressure. Successive detector improvements are increasing sensitivity, enabling not only increase the detection rate but also detections with high signal to noise ratios. To optimally extract information from these detected signals, continual effort is directed at pushing the state of the art of the interferometer calibration accuracy. To improve the accuracy of the locally-maintained laser power standards for photon calibration, a new global calibration scheme was implemented by using transfer standards calibrated at both the National Institute of Standards and Tech- nology (NIST) in the US and the Physikalisch-Technische Bundesanstalt (PTB) in Germany during the recently completed fourth observing run. We report the results of a long-duration NIST-PTB bilateral comparison conducted over almost three years and the results of propagation of transfer standard calibrations to the reference power sensors maintained at each observatory.

astro-ph.IM↗

From the Virgo interferometer calibration to the bias and uncertainty of the h(t) detector strain during the O4 run

Since the first gravitational wave detection in 2015, ground-based interferometer sensitivities have significantly improved, requiring highly precise calibration to ensure accurate reconstruction of the h(t) strain signal. In this talk we will outline the Virgo interferometer calibration steps performed in preparation of the O4b run started in April 2024. We will first describe the Photon Calibrator power devices intercalibration allowing for a 0.48% precision on mirror displacement. Before explaining how the Photon Calibrator is used to calibrate every Virgo mirror actuators. We will also discuss the monitoring of the h(t) strain reconstruction during the run showing that, on the 10 Hz to 2 kHz band, the reconstructed strain achieves a precision of 2% in modulus and 30 mrad in phase. Special emphasis will be given on the newly developed frequency-dependent bias and uncertainty computation method and the resulting online unbiasing of the h(t) strain.

physics.ins-det↗