Searcharxiv⌕ Search

arXiv subjects

Lorena Escudero Sanchez

Publications and source records attributed to Lorena Escudero Sanchez.

6 recordsLinked to original sources

Submanifold Sparse Convolutional Networks for Automated 3D Segmentation of Kidneys and Kidney Tumours in Computed Tomography

Accurate delineation of kidney tumours in Computed Tomography (CT) is essential for downstream quantitative analysis and precision oncology, but manual segmentation is a specialised task, time-consuming and difficult to scale. Automated 3D segmentation remains challenging because CT scans are large volumetric images, making high-resolution dense convolutional networks computationally expensive and often dependent on downsampling or patch-based inference. We propose a two-stage 3D segmentation methodology based on voxel sparsification and submanifold sparse convolutional networks (SSCNs). Stage 1 uses a low-resolution sparse network to identify a region of interest (ROI); Stage 2 applies a high-resolution sparse network for refined segmentation within the cropped ROI. This enables native high-resolution 3D processing while reducing memory use and inference time. We evaluate the method on the KiTS23 renal cancer CT dataset using 5-fold cross-validation. Our method achieved Dice similarity coefficients of 95.8% for kidneys + masses, 85.7% for tumours + cysts, and 80.3% for tumours alone, competitive with top KiTS23 approaches. In direct comparisons on the same cross-validation folds, the proposed sparse method achieves tumour + cyst and tumour-only Dice scores comparable to, and slightly higher than, a patch-based nnU-Net baseline, while consistently requiring less VRAM and shorter inference time across the tested hardware. Across the tested GPUs, our sparse model is markedly faster than both nnU-Net and the zero-shot zoom-out/zoom-in foundation model SegVol, which localises kidneys well but underperforms on small heterogeneous lesions. Compared to an equivalent dense implementation of the same architecture, the proposed sparse approach achieves up to a 60% reduction in inference time and up to a 75% reduction in VRAM usage across both CPU and the GPU configurations tested.

cs.CV↗

Developing Predictive and Robust Radiomics Models for Chemotherapy Response in High-Grade Serous Ovarian Carcinoma

Objectives: High-grade serous ovarian carcinoma (HGSOC) is typically diagnosed at an advanced stage with extensive peritoneal metastases, making treatment challenging. Neoadjuvant chemotherapy (NACT) is often used to reduce tumor burden before surgery, but about 40% of patients show limited response. Radiomics, combined with machine learning (ML), offers a promising non-invasive method for predicting NACT response by analyzing computed tomography (CT) imaging data. This study aimed to improve response prediction in HGSOC patients undergoing NACT by integration different feature selection methods. Materials and methods: A framework for selecting robust radiomics features was introduced by employing an automated randomisation algorithm to mimic inter-observer variability, ensuring a balance between feature robustness and prediction accuracy. Four response metrics were used: chemotherapy response score (CRS), RECIST, volume reduction (VolR), and diameter reduction (DiaR). Lesions in different anatomical sites were studied. Pre- and post-NACT CT scans were used for feature extraction and model training on one cohort, and an independent cohort was used for external testing. Results: The best prediction performance was achieved using all lesions combined for VolR prediction, with an AUC of 0.83. Omental lesions provided the best results for CRS prediction (AUC 0.77), while pelvic lesions performed best for DiaR (AUC 0.76). Conclusion: The integration of robustness into the feature selection processes ensures the development of reliable models and thus facilitates the implementation of the radiomics models in clinical applications for HGSOC patients. Future work should explore further applications of radiomics in ovarian cancer, particularly in real-time clinical settings.

cs.CV↗

Intensity Normalization Techniques and Their Effect on the Robustness and Predictive Power of Breast MRI Radiomics

Radiomics analysis has emerged as a promising approach for extracting quantitative features from medical images to aid in cancer diagnosis and treatment. However, radiomics research currently lacks standardization, and radiomics features can be highly dependent on the acquisition and pre-processing techniques used. In this study, we aim to investigate the effect of various intensity normalization techniques on the robustness of radiomics features extracted from MRI scans of breast cancer patients. The images used are from the publicly available I-SPY TRIAL dataset, which contains MRI scans of stage 2 or 3 breast cancer patients and from the Platinum and PARP inhibitor for Neoadjuvant treatment of Triple Negative and / or BRCA positive breast cancer (PARTNER) trial. We compared the effect of commonly used intensity normalization techniques on the robustness of radiomics features using Intraclass Correlation Coefficient (ICC) between multiple combinations of normalization approaches, identified categories that are robust and therefore could be compared between studies regardless of the pre-processing used. We were able to show that while systematic differences between MRI scanners can significantly affect many radiomics features, a combination of Bias Field correction with piecewise linear histogram normalization can mitigate some of the effects compared to other normalization methods investigated in this paper. We were able to demonstrate the importance of carefully selecting and standardizing normalization methods for accurate and reliable radiomics analysis in breast MRI scans.

physics.med-ph↗

Automated Segmentation of Computed Tomography Images with Submanifold Sparse Convolutional Networks

Quantitative cancer image analysis relies on the accurate delineation of tumours, a very specialised and time-consuming task. For this reason, methods for automated segmentation of tumours in medical imaging have been extensively developed in recent years, being Computed Tomography one of the most popular imaging modalities explored. However, the large amount of 3D voxels in a typical scan is prohibitive for the entire volume to be analysed at once in conventional hardware. To overcome this issue, the processes of downsampling and/or resampling are generally implemented when using traditional convolutional neural networks in medical imaging. In this paper, we propose a new methodology that introduces a process of sparsification of the input images and submanifold sparse convolutional networks as an alternative to downsampling. As a proof of concept, we applied this new methodology to Computed Tomography images of renal cancer patients, obtaining performances of segmentations of kidneys and tumours competitive with previous methods (~84.6% Dice similarity coefficient), while achieving a significant improvement in computation time (2-3 min per training epoch).

eess.IV↗

Calibrating Ensembles for Scalable Uncertainty Quantification in Deep Learning-based Medical Segmentation

Uncertainty quantification in automated image analysis is highly desired in many applications. Typically, machine learning models in classification or segmentation are only developed to provide binary answers; however, quantifying the uncertainty of the models can play a critical role for example in active learning or machine human interaction. Uncertainty quantification is especially difficult when using deep learning-based models, which are the state-of-the-art in many imaging applications. The current uncertainty quantification approaches do not scale well in high-dimensional real-world problems. Scalable solutions often rely on classical techniques, such as dropout, during inference or training ensembles of identical models with different random seeds to obtain a posterior distribution. In this paper, we show that these approaches fail to approximate the classification probability. On the contrary, we propose a scalable and intuitive framework to calibrate ensembles of deep learning models to produce uncertainty quantification measurements that approximate the classification probability. On unseen test data, we demonstrate improved calibration, sensitivity (in two out of three cases) and precision when being compared with the standard approaches. We further motivate the usage of our method in active learning, creating pseudo-labels to learn from unlabeled images and human-machine collaboration.

cs.LG↗

Advancing COVID-19 Diagnosis with Privacy-Preserving Collaboration in Artificial Intelligence

Artificial intelligence (AI) provides a promising substitution for streamlining COVID-19 diagnoses. However, concerns surrounding security and trustworthiness impede the collection of large-scale representative medical data, posing a considerable challenge for training a well-generalised model in clinical practices. To address this, we launch the Unified CT-COVID AI Diagnostic Initiative (UCADI), where the AI model can be distributedly trained and independently executed at each host institution under a federated learning framework (FL) without data sharing. Here we show that our FL model outperformed all the local models by a large yield (test sensitivity /specificity in China: 0.973/0.951, in the UK: 0.730/0.942), achieving comparable performance with a panel of professional radiologists. We further evaluated the model on the hold-out (collected from another two hospitals leaving out the FL) and heterogeneous (acquired with contrast materials) data, provided visual explanations for decisions made by the model, and analysed the trade-offs between the model performance and the communication costs in the federated training process. Our study is based on 9,573 chest computed tomography scans (CTs) from 3,336 patients collected from 23 hospitals located in China and the UK. Collectively, our work advanced the prospects of utilising federated learning for privacy-preserving AI in digital health.

cs.AI↗