SearcharxivSearch

arXiv subjects

Lorenza Ferrari

Publications and source records attributed to Lorenza Ferrari.

7 recordsLinked to original sources

Successful irradiation campaign on PRIMA/PRIMAger KIDs detectors with DRACuLA

DRACuLA (Detector irRAdiation Cryogenic faciLity for Astrophysics) is a mobile dilution refrigerator platform developed at the Institut d'Astrophysique Spatiale (IAS) to expose sub-Kelvin detectors to particle beams at their nominal operating temperature, in the range 50-300 mK. We report on its design, beam-line integration at the Particle Therapy Research Center (PARTREC) in Groningen, and the operational performance achieved during the September 2025 irradiation campaign on Kinetic Inductance Detector (KID) arrays developed by SRON for the PRIMA mission. The detector samples were maintained at 120 mK throughout a 12-hour proton irradiation run at 184 MeV. The scientific results of this campaign are reported in the companion paper by Besnard et al.

astro-ph.IM

Assessment of PLATO Science Performance

The PLATO mission is scheduled for launch early 2027. In this paper we present an overview of the performance drivers for the mission at the time where all flight models of the cameras have been tested and integrated on the optical bench. The PLATO consortium needs an estimate of the planet detection yield to dimension the ground-based radial velocity follow-up resources. We provide updated estimates on the yield of planet detections that can be expected from the mission under certain assumptions. As of today, large uncertainties remain on the planet occurrence rates, especially for small planets in long-period orbits, and on our ability to detect these planets in the presence of stellar variability and instrumental noise. To partially overcome these limitations, we compare results using different planet occurrence rates, detectability rates, and we include an estimate on the expected contribution of stellar variability to the noise budget. The final detection yield of PLATO will provide constraints to planet occurrence rates which in turn will help constraining planet formation models.

astro-ph.EP

PRIMA: PRIMAger, a far-infrared hyperspectral and polarimetric instrument

The PRobe far-Infrared Mission for Astrophysics (PRIMA) is an infrared observatory for the next decade, currently in Phase A, with a 1.8m telescope actively cooled to 4.5K. On board, an infrared camera, PRIMAger, equipped with ultra-sensitive kinetic inductance detector (KID) arrays, will provide observers with coverage of mid-infrared to far-infrared wavelengths from 24 to 264 microns. PRIMAger will offer two imaging modes: the Hyperspectral mode will cover the 24-84 microns wavelength range with a spectral resolution R=8, while the Polarimetric mode will provide polarimetric imaging in 4 broad bands, from 80 to 264 microns. These observational capabilities have been tailored to answer fundamental astrophysical questions such as black hole and star-formation co-evolution in galaxies, the evolution of small dust grains over a wide range of redshifts, and the effects of interstellar magnetic fields in various environments, as well as to open a vast discovery space with versatile photometric and polarimetric capabilities. PRIMAger is being developed by an international collaboration bringing together French institutes (Laboratoire d'Astrophysique de Marseille and CEA) through the center National d'Etudes Spatiales (CNES, France), the Netherlands Institute for Space Research (SRON, Netherlands), and the Cardiff University (UK) in Europe, as well as the Jet Propulsion Laboratory (JPL) and Goddard Space Flight Center (GSFC) in the USA.

astro-ph.IM

Lens based Kinetic Inductance Detectors with Distributed Dual Polarised Absorbers for Far Infra-red Space-based Astronomy

Future space-based far infra-red astronomical observations require background limited detector sensitivities and scalable focal plane array solutions to realise their vast potential in observation speed. In this work, a focal plane array of lens absorber coupled Kinetic Inductance Detectors (KIDs) is proposed to fill this role. The figures of merit and design guidelines for the proposed detector concept are derived by employing a previously developed electromagnetic spectral modelling technique. Two designs operating at central frequencies of $6.98$ and $12$ THz are studied. A prototype array of the former is fabricated, and its performance is experimentally determined and validated. Specifically, the optical coupling of the detectors to incoherent distributed sources (i.e. normalised throughput) is quantified experimentally with good agreement with the estimations provided by the model. The coupling of the lens absorber prototypes to an incident plane wave, i.e. aperture efficiency, is also indirectly validated experimentally matching the expected value of $54\%$ averaged over two polarisation. The noise equivalent power of the KIDs are also measured with limiting value of $8\times10^{-20}$ $\mathrm{W/\sqrt{Hz}}$.

astro-ph.IM

Demonstration of Ultra-Sensitive KIDs for Future THz Space Borne Polarimeters

We present measurements and simulations of the polarization purity of leaky lens-antenna coupled microwave Kinetic Inductance Detectors (KIDs) at 1.5 THz. We find the integrated cross-polarization level to be at -21.5 dB for 1 f\#$\lambda$ spatial sampling. The measurements agree well with the theoretical description which is based on a combination of in-transmission simulation of the antenna feed, and an in-reception analysis of the antenna-KID system. Combined with the measured noise equivalent power of 5--7$\times$10$^{-20}$ W/$\sqrt{\mathrm{Hz}}$, these detectors are excellent candidates for large scale and high performance imaging polarimetric instruments.

astro-ph.IM

Eliminating stray radiation inside large area imaging arrays

With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the response from a point source at the pixel position is at a similar level to the stray response integrated over the entire chip area. For the antenna coupled arrays, we show that this effect can be suppressed by incorporating an on-chip stray light absorber. A similar method should be possible with the LEKID array, especially when they are lens coupled.

astro-ph.IM

Surface wave control for large arrays of microwave kinetic inductance detectors

Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field measurements of the MKID optical response versus the position on the array of a reimaged optical source. We demonstrate that the optical response of a detector in these arrays saturates off-pixel at the $\sim-30$ dB level compared to the peak pixel response. The result is that the power detected from a point source at the pixel position is almost identical to the stray response integrated over the chip area. With such a contribution, it would be impossible to measure extended sources, while the point source sensitivity is degraded due to an increase of the stray loading. However, we show that by incorporating an on-chip stray light absorber, the surface wave contribution is reduced by a factor $>$10. With the on-chip stray light absorber the point source response is close to simulations down to the $\sim-35$ dB level, the simulation based on an ideal Gaussian illumination of the optics. In addition, as a crosscheck we show that the extended source response of a single pixel in the array with the absorbing grid is in agreement with the integral of the point source measurements.

astro-ph.IM