Expected performance of the TT-PET scanner

The TT-PET collaboration is developing a small animal TOF-PET scanner based on silicon detectors featuring 30 ps RMS time resolution and intended to be inserted in an existing MRI scanner. The TT-PET scanner makes use of a stack of layers of high-Z photon-converter and 100 $\mathrm{μm}$ thick silicon sensors, to achieve a scanner with 0.5 $\mathrm{\times}$ 0.5 $\mathrm{\times}$ 0.2 $\mathrm{mm^{3}}$ granularity, with precise depth-of-interaction measurement. In this paper we present the results of the Monte Carlo studies for the expected data rate, time resolution on the TOF measurements, spatial resolution and image reconstruction with and without the use of the timing information. Most of the studies have been performed according to the international standards used to assess the performance of small-animal PET system.

physics.med-ph↗

Characterization of the demonstrator of the fast silicon monolithic ASIC for the TT-PET project

The TT-PET collaboration is developing a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 3 x 10 pixel matrix integrated with the front-end, a 50 ps binning TDC and read out logic. The chip, thinned down to 100 μm and backside metallized, was operated at a voltage of 180 V. The tests on a beam line of minimum ionizing particles show a detection efficiency greater than 99.9 % and a time resolution down to 110 ps.

physics.ins-det↗

A monolithic ASIC demonstrator for the Thin Time-of-Flight PET scanner

Time-of-flight measurement is an important advancement in PET scanners to improve image reconstruction with a lower delivered radiation dose. This article describes the monolithic ASIC for the TT-PET project, a novel idea for a high-precision PET scanner for small animals. The chip uses a SiGe Bi-CMOS process for timing measurements, integrating a fully-depleted pixel matrix with a low-power BJT-based front-end per channel, integrated on the same 100 $μ m$ thick die. The target timing resolution is 30 ps RMS for electrons from the conversion of 511 keV photons. A novel synchronization scheme using a patent-pending TDC is used to allow the synchronization of 1.6 million channels across almost 2000 different chips at picosecond-level. A full-featured demonstrator chip with a 3x10 matrix of 500x500 $μ m^{2}$ pixels was produced to validate each block. Its design and experimental results are presented here.

physics.ins-det↗

Design a TDC in SiGe for RPC's electronics Front-end for the use in a high-rate experiment

With the new generation of the RPC, it is possible to work with induced signals of hundreds $μV$, hence the front-end electronics is an important and delicate part of the detector in order to get a detectable signal. The electronic chain is made up of an amplifier, a discriminator, a TDC. The new front-end is realized with the use of silicon-germanium (SiGe) components, provided by IHP microelectronics. With this technology we can implement BJT and CMOS transistors on the same chip. The benefit of this improvement is to minimize: power consumption of the channels ($2 ÷3$ $ \frac{mW}{ch}$), noise (500 $e^-$ r.m.s), radiation hardness (10 kGy,$10^3$ $\frac{n}{cm}$) and it maximizes the speed of response electronics. In this work I will highlight the first TDC prototypes' results. The TDC uses a local oscillator, that has an oscillation range between $0.6 ÷3 $ GHz, and a the temporal jitter of 15 ps. The data output from the TDC are presented in binary in order to lighten data processing to the acquisition system. Moreover, we are studying a way to minimize system latency. This optimization involves the addition of a serializer (PISO) that sends the TDC data output to the acquisition system at 2 GHz.

physics.ins-det↗

100ps time resolution with thin silicon pixel detectors and a SiGe HBT amplifier

A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the H8 beam line at the CERN SPS. An excellent time resolution of (106+-1)ps for silicon detectors was measured with minimum ionizing particles.

physics.ins-det↗