SearcharxivSearch

arXiv subjects

Louis Maillard

Publications and source records attributed to Louis Maillard.

2 recordsLinked to original sources

Automatic detection of abnormal clinical EEG: comparison of a finetuned foundation model with two deep learning models

Electroencephalography (EEG) is commonly used by physicians for the diagnosis of numerous neurological disorders. Due to the large volume of EEGs requiring interpretation and the specific expertise involved, artificial intelligence-based tools are being developed to assist in their visual analysis. In this paper, we compare two deep learning models (CNN-LSTM and Transformer-based) with BioSerenity-E1, a recently proposed foundation model, in the task of classifying entire EEG recordings as normal or abnormal. The three models were trained or finetuned on 2,500 EEG recordings and their performances were evaluated on two private and one public datasets: a large multicenter dataset annotated by a single specialist (dataset A composed of n = 4,480 recordings), a small multicenter dataset annotated by three specialists (dataset B, n = 198), and the Temple University Abnormal (TUAB) EEG corpus evaluation dataset (n = 276). On dataset A, the three models achieved at least 86% balanced accuracy, with BioSerenity-E1 finetuned achieving the highest balanced accuracy (89.19% [88.36-90.41]). BioSerenity-E1 finetuned also achieved the best performance on dataset B, with 94.63% [92.32-98.12] balanced accuracy. The models were then validated on TUAB evaluation dataset, whose corresponding training set was not used during training, where they achieved at least 76% accuracy. Specifically, BioSerenity-E1 finetuned outperformed the other two models, reaching an accuracy of 82.25% [78.27-87.48]. Our results highlight the usefulness of leveraging pre-trained models for automatic EEG classification: enabling robust and efficient interpretation of EEG data with fewer resources and broader applicability.

q-bio.NC

Evaluation of Performance for Human In-Vivo Conductivity Estimation from EEG and sEEG Recorded in Simultaneous with Intracerebral Electrical Stimulation

Assigning accurate conductivity values in human head models is an essential factor for performing precise electroencephalographic (EEG) source localization and targeting of transcranial electrical stimulation (TES). Unfortunately, the literature reports diverging conductivity values of the different tissues in the human head. The current study analyzes first the performance of in-vivo conductivity estimation for different configurations concerning the localization of the electrical source and measurement. Then, it presents conductivity estimates for three epileptic patients using scalp EEG and intracerebral stereotactic EEG (sEEG) acquired in simultaneous with intracerebral electrical stimulation. The estimates of the conductivities were based on finite-element models of the human head with five tissue compartments of homogeneous and isotropic conductivities. The results of this study show that in-vivo conductivity estimation can lead to different estimated conductivities for the same patient when considering different stimulation positions, different measurement positions or different measurement modalities (sEEG or EEG). This work provides important guidelines to in-vivo conductivity estimation and explains the variability among the conductivity values which have been reported in previous studies.

q-bio.NC