3D source tracking and error detection in HDR using two independent scintillator dosimetry systems

The high dose gradients near the source characteristics of brachytherapy are equivalent to nefarious effects if unnoticed errors take place during the patient treatment. In vivo dosimetry is the only method to quantify the delivered dose. Previous studies to this one, have characterized potential detectors that can be used as in vivo dosimeter. Some of them have focused on the source tracking topic in HDR brachytherapy. The aim of this study is to perform 3D source position reconstruction by combining in vivo dosimetry measurements from two independent detector systems. The first was based on multiple (three) plastic scintillator detectors and the second on a single inorganic crystal (CsI:Tl). By combining two detector responses, we enabled the determination of the absolute source coordinates in 3D space. The method in this study proposed can be extended to the combination of different systems.

physics.med-ph↗

From conception to clinical trial: IViST -- the first multi-sensor-based platform for real-time In Vivo dosimetry and Source Tracking in HDR brachytherapy

This study aims to introduce IViST (In Vivo Source Tracking), a novel multi-sensors dosimetry platform for real-time treatment monitoring in HDR brachytherapy. IViST is a platform that comprises 3 parts: 1) an optimized and characterized multi-point plastic scintillator dosimeter (3 points mPSD; using BCF-60, BCF-12, and BCF-10 scintillators), 2) a compact assembly of photomultiplier tubes (PMTs) coupled to dichroic mirrors and filters for high-sensitivity scintillation light collection, and 3) a Python-based graphical user interface used for system management and signal processing. IViST can simultaneously measure dose, triangulate source position, and measure dwell time. By making 100 000 measurements/s, IViST samples enough data to quickly perform key QA/QC tasks such as identifying wrong individual dwell time or interchanged transfer tubes. By using 3 co-linear sensors and planned information for an implant geometry (from DICOM RT), the platform can also triangulate source position in real-time. A clinical trial is presently on-going using the IViST system.

physics.med-ph↗

Light-Generating CdSe/CdS Colloidal Quantum Dot-Doped Plastic Optical Fibers

Colloidal quantum dots (cQDs) are now a mature nanomaterial with optical properties customizable through varying size and composition. However, their use in optical devices is limited as they are not widely available in convenient forms such as optical fibers. With advances in polymerization methods incorporating nanocrystals, nanocomposite materials suitable for processing into high quality hybrid active fibers can be achieved. We demonstrate a plastic optical fiber fabrication method which ensures homogeneous dispersion of cQDs within a polymer core matrix. Loading concentrations between 10$^{11}$-10$^{13}$ CdSe/CdS cQDs per cm$^{3}$ in polystyrene were electronically imaged, confirming only sporadic sub-wavelength aggregates. Rayleigh scattering losses are therefore dominant at energies below the semiconductors' band gap, but are overtaken by a sharp CdS-related absorption onset around 525 nm facilitating cQD excitation. The redshifted photoluminescence emission is then minimally reabsorbed along the fiber with a spectrum barely affected by the polymerization and a quantum yield staying at $\sim$65$\%$ of its initial value. The latter, along with the glass transition temperature and refractive index, is independent of the cQD concentration hence yielding a proportionally increasing light output. Our cQD-doped fibers are photostable to within 5$\%$ over days showing great promise for functional material applications.

physics.app-ph↗

On the use of machine learning methods for mPSD calibration in HDR brachytherapy

Purpose: We sought to evaluate the feasibility of using machine learning algorithms for multipoint plastic scintillator detector calibration in high-dose-rate brachytherapy. Methods: The dosimetry system consisted of an optimized 1-mm-core mPSD and a compact assembly of photomultiplier tubes coupled with dichroic mirrors and filters. An $^{192}$Ir source was remotely controlled and sent to various positions in a homemade PMMA holder. Dose measurements covering a range of 0.5 to 12 cm of source displacement were carried out according to TG-43 recommendations. Individual scintillator doses were decoupled using a linear regression model, a random forest estimator, and artificial neural network algorithms. The performance of the different algorithms was evaluated using different sample sizes and distances to the source for the mPSD system calibration. Results: The decoupling methods' deviations from the expected TG-43 dose generally remained below 20%. However, the dose prediction with the three algorithms was accurate to within 7% relative to the dose predicted by the TG-43 formalism for measurements performed in the same range of distances used for calibration. The performance random forest was compromised when the predictions were done beyond the range of distances used for calibration. The dose prediction by the linear regression was less influenced by the calibration conditions than random forest, but with more significant deviations. The number of available measurements for training purposes influenced the random forest and neural network models the most. Their accuracy tended to converge toward deviation values close to 1% from a number of dwell positions greater than 100. Conclusions: In performing HDR brachytherapy dose measurements with an optimized mPSD system, ML algorithms are good alternatives for precise dose reporting and treatment assessment.

physics.med-ph↗

Dosimetric performance of a multi-point plastic scintillator dosimeter as a tool for real-time source tracking in high dose rate brachytherapy

Purpose: To present the performance of a multi-point plastic scintillation detector (mPSD) as a tool in vivo dosimetry in brachytherapy. Methods: A previously optimized three-point sensor system was used for in vivo HDR brachytherapy measurements (using the scintillators BCF-60, BCF-12, and BCF-10). The light detection system of the mPSD consisted of compactly assembled photomultiplier tubes (PMTs) and dichroic mirrors and filters to achieve a highly sensitive scintillation light collection. The PMT signals were recorded using a NI-DAQ board at a rate of 100 kHz. Dose measurements covering a range of 0.5 to 10 cm from the 192Ir source were carried out according to TG-43 U1 recommendations in order to: (1) characterize the system's response in terms of angular dependence; (2) obtain the relative contribution of positioning and measurement uncertainties to the total system uncertainty; (3) assess the system's temporal resolution; and (4) track the source position in real time. Results: The positioning uncertainty dominated close to the source, whereas the measurement uncertainty dominated at larger distances. A maximum measurement uncertainty of 17 % was observed for the BCF-60 scintillator at 10 cm from the source. The average best compromise between positioning and measurement uncertainties were reached at 17.4 mm. The detector further exhibited no angular dependence. The system provided an average location with a standard deviation under 1.7 mm. The maximum observed differences between measured and expected source location was 1.82 mm. Dose deviations remained below 5% in all the explored measurement conditions. With regard to dwell time measurement accuracy, the maximum deviation observed at all distances was 0.56 s. Conclusions: The performance of the system demonstrated that it could be used for real-time dose, position and dwell time measurements during HDR brachytherapy.

physics.med-ph↗

Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy

Purpose: This study aims to optimize and characterize the response of a mPSD for in vivo dosimetry in HDR brachytherapy. Methods: An exhaustive analysis was carried out in order to obtain an optimized mPSD design that maximize the scintillation light collection produced by the interaction of ionizing photons. Several mPSD prototypes were built and tested in order to determine the appropriate order of scintillators relative to the photodetector, as well as their length as a function of the scintillation light emitted. Scintillators BCF-60, BCF-12 and BCF-10 constituted the mPSD sensitive volume.Each scintillator contribution to the total spectrum was determined by irradiations in the low energy range.For the best mPSD design, a numerical optimization was done in order to select the optical components that better match the light emission profile. The optimized dosimetric system was used for HDR brachytherapy dose determination. The system performance was quantified in term of signal to noise ratio and signal to background ratio. Results: It was determined that BCF-60 should be placed at the distal position, BCF-12 in the center and BCF-10 at proximal position with respect to the photodetector.This configuration allowed for optimized light transmission through the collecting fiber, avoiding inter-scintillator excitation and self-absorption effects.The optimized luminescence system allowed for signal deconvolution using a multispectral approach, extracting the dose to each element while taking into account Cerenkov stem effect.Differences between the mPSD measurements and TG-43 remain below 5%. In all measurement conditions, the system was able to properly differentiate the produced scintillation signal from the background one. Conclusions: A mPSD was constructed and optimized for HDR brachytherapy dosimetry, enabling real time dose determination, up to 6.5cm from the 192Ir source.

physics.med-ph↗

Investigation of the quinine sulfate dihydrate spectral properties and its effects on Cherenkov dosimetry

Recent studies have proposed that adding quinine to water while performing Cherenkov volumetric dosimetry improves the skewed percent depth dose measurement. The aim of this study was to quantify the ability of quinine to convert directional Cherenkov emission to isotropic fluorescence and evaluate its contribution to the total emitted light. Aqueous solutions of quinine were prepared with distilled water at various concentrations (0.01 to 1.2 g/L). The solutions were irradiated with photon beams at 6 and 23 MV. The dependence of the light produced as a function of sample concentration was studied using a spectrometer with a fixed integration time. Spectral measurements of the luminescent solution and the blank solution (distilled water only) were taken to deconvolve the Cherenkov and quinine contribution to the overall emission spectrum. Using a CCD camera, intensity profiles were obtained for the blank and the 1.00 g/L solutions to compare them with the dose predicted by a treatment planning system. The luminescent intensity of the samples was found to follow a logarithmic trend as a function of the quinine concentration. Based on the spectral deconvolution of the 1.00 g/L solution, 52.4% and 52.7% of the signal in the visible range results from the quinine emission at 6 and 23 MV, respectively. The remaining fraction of the spectrum is due to the Cherenkov light that has not been converted. The fraction of the Cherenkov emission produced between 250 nm and 380 nm in the water and that was absorbed by the fluorophore reached 24.8% and 9.4% respectively at 6 and 23 MV. X-ray stimulated fluorescence of the quinine was then proven to be the principal cause to the increased total light output compared to the water-only signal. This new information reinforces the direct correlation of the solution intensity to the dose deposition.

physics.med-ph↗

A GPU-based multi-criteria optimization algorithm for HDR brachytherapy

Currently in HDR brachytherapy planning, a manual fine-tuning of an objective function is necessary to obtain case-specific valid plans. This study intends to facilitate this process by proposing a patient-specific inverse planning algorithm for HDR prostate brachytherapy: GPU-based multi-criteria optimization (gMCO). Two GPU-based optimization engines including simulated annealing (gSA) and a quasi-Newton optimizer (gL-BFGS) were implemented to compute multiple plans in parallel. After evaluating the equivalence and the computation performance of these two optimization engines, one preferred optimization engine was selected for the gMCO algorithm. Five hundred sixty-two previously treated prostate HDR cases were divided into validation set (100) and test set (462). In the validation set, the number of Pareto optimal plans to achieve the best plan quality was determined for the gMCO algorithm. In the test set, gMCO plans were compared with the physician-approved clinical plans. Over 462 cases, the number of clinically valid plans was 428 (92.6%) for clinical plans and 461 (99.8%) for gMCO plans. The number of valid plans with target V100 coverage greater than 95% was 288 (62.3%) for clinical plans and 414 (89.6%) for gMCO plans. The mean planning time was 9.4 s for the gMCO algorithm to generate 1000 Pareto optimal plans. In conclusion, gL-BFGS is able to compute thousands of SA equivalent treatment plans within a short time frame. Powered by gL-BFGS, an ultra-fast and robust multi-criteria optimization algorithm was implemented for HDR prostate brachytherapy. A large-scale comparison against physician approved clinical plans showed that treatment plan quality could be improved and planning time could be significantly reduced with the proposed gMCO algorithm.

physics.med-ph↗

Technical Note: A Novel Electromagnetic-Tracked Scintillation Dosimeter for Accurate In Vivo Dosimetry in HDR Brachytherapy

Since large dose are administrated to the patient in brachytherapy treatment, ensuring the right dose is delivered is highly critical. This study presents a first step in solving the standing issue of accurately knowing the dosimeter position at all time during in vivo dosimetry. In this work, an energy independent dosimeter, namely plastic scintillation detector, is coupled to an electromagnetic (EM) sensor having sub-mm positional accuracy for real-time tracking of the dosimeter position. However, adding an EM sensor adds materials in the path to the scintillator and thus could potentially perturb the dose measurements.To confirm the perturbation presence, 4 different sensors were placed in front of the scintillator so the radiation does not arrive to it directly. Variation of the distance between the sensor and the scintillator was used to quantify the effect on the signal at 0° and 90°.To test the dependence for each sensor, the signal measurement were taken from 0° to 90° with 10$°$ increment. The 5PCBDOF sensor showed an increased signal of almost $20{\%}$ with increasing beam angle. Sensor 5DOF, 5DOFthin and 6DOFshowed no significant angle dependance.The 6DOF and 5DOFthin sensor's cable revealed no extra signal attenuation. The latter gives a smaller overall attenuation. Therefore, the 5DOFthin is chosen to be part of the novel dosimeter construction. It has a jitter error of $\pm$ 0.06 mm and a reproductibility of$ {\pm}$ 0.008 mm. In the optimal operating range, the average positional uncertainty is less than 0.2 mm. Average angle errors are at most of 1.1$°$. It is feasible to integrate an EM tracking sensor to an energy independent plastic scintillation dosimeter with minimal impact to the collected signal as well as sufficient positional accuracy to keep dose uncertainty below 5${\%}$.

physics.med-ph↗

A theoretical framework to predict the most likely ion path in particle imaging

In this work, a generic rigorous Bayesian formalism is introduced to predict the most likely path of any ion crossing a medium between two detection points. The path is predicted based on a combination of the particle scattering in the material and measurements of its initial and final position, direction and energy. The path estimate's precision is compared to the Monte Carlo simulated path. Every ion from hydrogen to carbon is simulated in two scenarios to estimate the accuracy achievable: one where the range is fixed and one where the initial velocity is fixed. In the scenario where the range is kept constant, the maximal root-mean-square error between the estimated path and the Monte Carlo path drops significantly between the proton path estimate (0.50 mm) and the helium path estimate (0.18 mm), but less so up to the carbon path estimate (0.09 mm). In the scenario where the initial velocity is kept constant, helium have systematically the minimal root-mean-square error throughout the path. As a result, helium is found to be the optimal particle for ion imaging.

physics.med-ph↗