SearcharxivSearch

arXiv subjects

Luca Callegaro

Publications and source records attributed to Luca Callegaro.

At least 19 recordsLinked to original sources

Traceable In Situ Microwave Power Measurement at the Cryogenic Device Plane in a Dilution Refrigerator

Accurate knowledge of the microwave power delivered to a cryogenic device under test (DUT) is essential for the characterization and operation of superconducting quantum circuits. However, this information is difficult to obtain inside dilution refrigerators because of distributed attenuation, impedance mismatch, switch-path repeatability, and temperature-dependent microwave components. This paper presents an in situ measurement method for RF power at the cryogenic device plane. The method uses a custom variable temperature stage (VTS) as a cryogenic thermal-transfer element. The TVS is alternately heated by a four-wire DC heater and by microwave power dissipated in a 20 dB pass-through attenuator. By fitting the thermal transients and comparing the corresponding steady-state temperatures, the absorbed microwave power is inferred from a directly measured DC electrical power through an AC/DC substitution procedure. The finite reflection and transmission of the attenuator are then accounted for by cryogenic two-port scattering-parameter measurements based on a switch-assisted Short--Open--Load--Reciprocal calibration, so that the result is referred to the DUT reference plane. The system is demonstrated in a dilution refrigerator with powers between -43 and -58 dBm at the DUT input plane. The demonstrated relative standard uncertainty ranges from about 2% at -43.9 dBm to about 40% at -57.6 dBm. The proposed approach combines thermal RF power transfer, cryogenic S-parameter correction, and uncertainty evaluation in a measurement architecture compatible with quantum-device experiments, providing a practical route toward traceable microwave-power calibration at millikelvin stages.

physics.ins-det

Device-Agnostic Microwave Noise Metrology for Nonlinear Cryogenic Quantum Devices

Microwave devices capable of near-quantum-limited signal processing are essential components in the toolbox of solid-state quantum technologies. The manipulation and readout of single-photon microwave signals through amplifiers, mixers, isolators, etc. must fulfill strict requirements in terms of signal integrity to ensure reliable operation. These active microwave quantum devices operate in complex cryo-electronic setups. This poses challenges to their characterization, since all relevant figures of merit must be expressed at the reference planes of their ports. Even though cryogenic S-parameter calibration is non-trivial, metrological approaches are converging toward rigorous methods. Furthermore, preserving signal integrity must be quantified via absolute noise levels at the ports of the Device Under Test (DUT), requiring an absolute power reference. In this work, we present an in situ noise metrology protocol based on substituting a controllable noise source for the DUT. We motivate this choice by showing that placing the noise source at the DUT input impacts the separability of the calibration from the DUT characteristics. Our proposed architecture combines Planck spectroscopy using a Variable Temperature Stage with Short-Open-Load-Reciprocal scattering-parameter calibration, so that noise and scattering quantities are referred to the same cryogenic reference planes. In this configuration, the readout-chain calibration is separated from the internal dynamics of the DUT. As a demanding use case, we apply the protocol to a Josephson Traveling Wave Parametric Amplifier and extract its gain and input-referred added noise under pump conditions activating multimode nonlinear behavior. This illustrates how our device-agnostic protocol supports portable noise characterization of nonlinear cryogenic microwave devices.

quant-ph

Towards Quantifying Two-Mode Correlation Linewidths in Quantum Circuits

This paper aims to quantify the linewidth of two-mode correlations in Traveling Wave Parametric Amplifiers (TWPAs). Artifacts induced by data acquisition and processing, such as windowing effects and acquisition time, are examined to understand their influence on the linewidth estimation of these correlations. The findings underscore the significance of acquisition parameters in optimizing two-mode correlation measurements, enhancing device characterization for quantum applications.

quant-ph

Nonlinear Behavior of Josephson Traveling Wave Parametric Amplifiers

Recent advancements in quantum technologies and advanced detection experiments have underscored the pressing need for the detection of exceedingly weak signals within the microwave frequency spectrum. Addressing this challenge, the Josephson Traveling Wave Parametric Amplifier (JTWPA) has been proposed as a cryogenic front-end amplifier capable of approaching the quantum noise limit while providing a relevant bandwidth. This research is centered on a comprehensive numerical investigation of the JTWPA, without resorting to simplifications regarding the nonlinearity of the essential components. Specifically, this study focuses on a thorough examination of the system, characterized by coupled nonlinear differential equations representing all components of the device. Proper input and output signals at the device's boundaries are considered. The analysis of the output signals undergoing the parametric amplification process involves a detailed exploration of phase-space dynamics and Fourier spectral analysis of the output voltage. This study is conducted while considering the parameters ruling the response of the device under pump and signal excitations. In addition to the expected signal amplification, the findings reveal that the nonlinear nature of the system can give rise to unforeseen phenomena, depending on the system's operational conditions, which include: the generation of pump tone harmonics, modulation of the signal gain, and incommensurate frequency generation-effects that are not easily accommodated by simplistic linearized approaches

cond-mat.supr-con

Broadband parametric amplification in DARTWARS

Superconducting parametric amplifiers offer the capability to amplify feeble signals with extremely low levels of added noise, potentially reaching quantum-limited amplification. This characteristic makes them essential components in the realm of high-fidelity quantum computing and serves to propel advancements in the field of quantum sensing. In particular, Traveling-Wave Parametric Amplifiers (TWPAs) may be especially suitable for practical applications due to their multi-Gigahertz amplification bandwidth, a feature lacking in Josephson Parametric Amplifiers (JPAs), despite the latter being a more established technology. This paper presents recent developments of the DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project, focusing on the latest prototypes of Kinetic Inductance TWPAs (KITWPAs). The project aims to develop a KITWPA capable of achieving $20\,$ dB of amplification. To enhance the production yield, the first prototypes were fabricated with half the length and expected gain of the final device. In this paper, we present the results of the characterization of one of the half-length prototypes. The measurements revealed an average amplification of approximately $9\,$dB across a $2\,$GHz bandwidth for a KITWPA spanning $17\,$mm in length.

quant-ph

Development of KI-TWPAs for the DARTWARS project

Noise at the quantum limit over a broad bandwidth is a fundamental requirement for future cryogenic experiments for neutrino mass measurements, dark matter searches and Cosmic Microwave Background (CMB) measurements as well as for fast high-fidelity read-out of superconducting qubits. In the last years, Josephson Parametric Amplifiers (JPA) have demonstrated noise levels close to the quantum limit, but due to their narrow bandwidth, only few detectors or qubits per line can be read out in parallel. An alternative and innovative solution is based on superconducting parametric amplification exploiting the travelling-wave concept. Within the DARTWARS (Detector Array Readout with Travelling Wave AmplifieRS) project, we develop Kinetic Inductance Travelling-Wave Parametric Amplifiers (KI-TWPAs) for low temperature detectors and qubit read-out. KI-TWPAs are typically operated in a threewave mixing (3WM) mode and are characterised by a high gain, a high saturation power, a large amplification bandwidth and nearly quantum limited noise performance. The goal of the DARTWARS project is to optimise the KI-TWPA design, explore new materials, and investigate alternative fabrication processes in order to enhance the overall performance of the amplifier. In this contribution we present the advancements made by the DARTWARS collaboration to produce a working prototype of a KI-TWPA, from the fabrication to the characterisation.

quant-ph

Good practice guide on the graphene-based AC-QHE realization of the farad

This Good Practice Guide provides information for the realization of the farad from the quantum Hall resistance in graphene devices by using digital impedance bridges. The fabrication and characterization of graphene quantum Hall effect devices, the cryogenic environment required to achieve the quantization conditions, the digital impedance bridges and calibration procedures are reported. The guide is a deliverable of the Joint Research Project EMPIR 18SIB07 GIQS: Graphene Impedance Quantum Standard. This project received funding from the European Metrology Programme for Innovation and Research (EMPIR) co-financed by the Participating States and from the European Unions' Horizon 2020 research and innovation programme. Funder ID: 10.13039/100014132 , Grant no: 18SIB07.

physics.ins-det

Nonconventional Quantized Hall Resistances Obtained with $ν= 2$ Equilibration in Epitaxial Graphene $p-n$ Junctions

We have demonstrated the millimeter-scale fabrication of monolayer epitaxial graphene $p-n$ junction devices using simple ultraviolet photolithography, thereby significantly reducing device processing time compared to that of electron beam lithography typically used for obtaining sharp junctions. This work presents measurements yielding nonconventional, fractional multiples of the typical quantized Hall resistance at $ν=2$ ($R_H\approx 12906 Ω$) that take the form: $\frac{a}{b}R_H$. Here, $a$ and $b$ have been observed to take on values such 1, 2, 3, and 5 to form various coefficients of $R_H$. Additionally, we provide a framework for exploring future device configurations using the LTspice circuit simulator as a guide to understand the abundance of available fractions one may be able to measure. These results support the potential for drastically simplifying device processing time and may be used for many other two-dimensional materials.

cond-mat.mes-hall

A quantum model for rf-SQUIDs based metamaterials enabling 3WM and 4WM Travelling Wave Parametric Amplification

A quantum model for Josephson-based metamaterials working in the Three-Wave Mixing (3WM) and Four-Wave Mixing (4WM) regimes at the single-photon level is presented. The transmission line taken into account, namely Traveling Wave Josephson Parametric Amplifier (TWJPA), is a bipole composed by a chain of rf-SQUIDs which can be biased by a DC current or a magnetic field in order to activate the 3WM or 4WM nonlinearities. The model exploits a Hamiltonian approach to analytically determine the time evolution of the system both in the Heisenberg and interaction pictures. The former returns the analytic form of the gain of the amplifier, while the latter allows recovering the probability distributions vs. time of the photonic populations, for multimodal Fock and coherent input states. The dependence of the metamaterial's nonlinearities is presented in terms of circuit parameters in a lumped model framework while evaluating the effects of the experimental conditions on the model validity.

cond-mat.supr-con

A simple algorithm to find the L-curve corner in the regularisation of ill-posed inverse problems

We propose a simple algorithm to locate the "corner" of an L-curve, a function often used to select the regularisation parameter for the solution of ill-posed inverse problems. The algorithm involves the Menger curvature of a circumcircle and the golden section search method. It efficiently finds the regularisation parameter value corresponding to the maximum positive curvature region of the L-curve. The algorithm is applied to some commonly available test problems and compared to the typical way of locating the l-curve corner by means of its analytical curvature. The application of the algorithm to the data processing of an electrical resistance tomography experiment on thin conductive films is also reported.

math.NA

Comment on "Physics without determinism: Alternative interpretations of classical physics", Phys. Rev. A, 100:062107, Dec 2019

The paper "Physics without determinism: Alternative interpretations of classical physics" [Phys. Rev. A, 100:062107, Dec 2019] defines finite information quantities (FIQ). A FIQ expresses the available information about the value of a physical quantity. We show that a change in the measurement unit does not preserve the information carried by a FIQ, and therefore that the definition provided in the paper is not complete.

quant-ph

Calibration setup for ultralow-current transresistance amplifiers

We describe a calibration setup for the transresistance of low-current amplifiers, based on the capacitance-charging method. The calibration can be performed in the current range of typical interest for electron counting experiments. The setup implementation is simple and rugged, and is suitable to be embedded in larger experiments where the amplifier is employed. The calibration is traceable to units of capacitance and of time. The base relative accuracy of the implementation is in the 10^-5 range.

physics.ins-det

Electrical Resistance Tomography of Conductive Thin Films

The Electrical Resistance Tomography (ERT) technique is applied to the measurement of sheet conductance maps of both uniform and patterned conductive thin films. Images of the sheet conductance spatial distribution, and local conductivity values are obtained. Test samples are tin oxide films on glass substrates, with electrical contacts on the sample boundary, some samples are deliberately patterned in order to induce null conductivity zones of known geometry while others contain higher conductivity inclusions. Four-terminal resistance measurements among the contacts are performed with a scanning setup. The ERT reconstruction is performed by a numerical algorithm based on the total variation regularization and the L-curve method. ERT correctly images the sheet conductance spatial distribution of the samples. The reconstructed conductance values are in good quantitative agreement with independent measurements performed with the van der Pauw and the four-point probe methods.

physics.ins-det

Circuit models and SPICE macro-models for quantum Hall effect devices

Quantum Hall effect (QHE) devices are a pillar of modern quantum electrical metrology. Electrical networks including one or more QHE elements can be used as quantum resistance and impedance standards. The analysis of these networks allows metrologists to evaluate the effect of the inevitable parasitic parameters on their performance as standards. This paper presents a systematic analysis of the various circuit models for QHE elements proposed in the literature, and the development of a new model. This last model is particularly suited to be employed with the analogue electronic circuit simulator SPICE. The SPICE macro-model and examples of SPICE simulations, validated by comparison with the corresponding analytical solution and/or experimental data, are provided.

physics.ins-det

On the calibration of direct-current current transformers

Modern commercial direct-current current transformers (DCCT) can measure currents up to the kA range with accuracies better than 1E-5. We discuss here a DCCT calibration method and its implementation with commercial instruments typically employed in low resistance calibration laboratories. The primary current ranges up to 2 kA; in the current range below \SI{100}{\ampere} the calibration uncertainty is better than 3E-7. An example of calibration of a high-performance DCCT specified for primary currents measurement up to 900 A is discussed in detail.

physics.ins-det

A three-arm current comparator bridge, for impedance comparisons over the complex plane

We present here the concept of three-arm current comparator impedance bridge, which allows comparisons among three unlike impedances. Its purpose is the calibration of impedances having arbitrary phase angles, against calibrated nearly-pure impedances. An analysis of the bridge optimal setting and proper operation is presented. To test the concept, a two terminal-pair digitally-assisted bridge has been realized; measurements of an air-core inductor and of an RC network versus decade resistance and capacitance standards, at kHz frequency, have been performed. The bridge measurements are compatible with previous knowledge of the standards' values with relative deviations in the 10^-5 -- 10^-6 range.

physics.ins-det

Experiences with a two terminal-pair digital impedance bridge

This paper describes the realization of a two terminal-pair digital impedance bridge and the test measurements performed with it. The bridge, with a very simple architecture, is based on a commercial two-channel digital signal synthesizer and a synchronous detector. The bridge can perform comparisons between impedances having arbitrary phase and magnitude ratio: its balance is achieved automatically in less than a minute. $R$-$C$ comparisons with calibrated standards, at kHz frequency and 100 kohm magnitude level, give ratio errors of the order of $10^{-6}$, with potential for further improvements.

physics.ins-det

Generation of reference dc currents at 1 nA level with the capacitance-charging method

The capacitance-charging method is a well-established and handy technique for the generation of dc current in the 100 pA range or lower. The method involves a capacitance standard and a sampling voltmeter, highly stable devices easy to calibrate, and it is robust and insensitive to the voltage burden of the instrument being calibrated. We propose here a range extender amplifier, which can be employed as a plug-in component in existing calibration setups, and allows the generation of currents in the 1 nA range. The extender has been employed in the INRIM setup and validated with two comparisons at 100 pA and 1 nA current level. The calibration accuracy achieved on a top-class instrument is 10 ppm at 1 nA.

physics.ins-det