Traceable In Situ Microwave Power Measurement at the Cryogenic Device Plane in a Dilution Refrigerator

Accurate knowledge of the microwave power delivered to a cryogenic device under test (DUT) is essential for the characterization and operation of superconducting quantum circuits. However, this information is difficult to obtain inside dilution refrigerators because of distributed attenuation, impedance mismatch, switch-path repeatability, and temperature-dependent microwave components. This paper presents an in situ measurement method for RF power at the cryogenic device plane. The method uses a custom variable temperature stage (VTS) as a cryogenic thermal-transfer element. The TVS is alternately heated by a four-wire DC heater and by microwave power dissipated in a 20 dB pass-through attenuator. By fitting the thermal transients and comparing the corresponding steady-state temperatures, the absorbed microwave power is inferred from a directly measured DC electrical power through an AC/DC substitution procedure. The finite reflection and transmission of the attenuator are then accounted for by cryogenic two-port scattering-parameter measurements based on a switch-assisted Short--Open--Load--Reciprocal calibration, so that the result is referred to the DUT reference plane. The system is demonstrated in a dilution refrigerator with powers between -43 and -58 dBm at the DUT input plane. The demonstrated relative standard uncertainty ranges from about 2% at -43.9 dBm to about 40% at -57.6 dBm. The proposed approach combines thermal RF power transfer, cryogenic S-parameter correction, and uncertainty evaluation in a measurement architecture compatible with quantum-device experiments, providing a practical route toward traceable microwave-power calibration at millikelvin stages.

physics.ins-det

Device-Agnostic Microwave Noise Metrology for Nonlinear Cryogenic Quantum Devices

Microwave devices capable of near-quantum-limited signal processing are essential components in the toolbox of solid-state quantum technologies. The manipulation and readout of single-photon microwave signals through amplifiers, mixers, isolators, etc. must fulfill strict requirements in terms of signal integrity to ensure reliable operation. These active microwave quantum devices operate in complex cryo-electronic setups. This poses challenges to their characterization, since all relevant figures of merit must be expressed at the reference planes of their ports. Even though cryogenic S-parameter calibration is non-trivial, metrological approaches are converging toward rigorous methods. Furthermore, preserving signal integrity must be quantified via absolute noise levels at the ports of the Device Under Test (DUT), requiring an absolute power reference. In this work, we present an in situ noise metrology protocol based on substituting a controllable noise source for the DUT. We motivate this choice by showing that placing the noise source at the DUT input impacts the separability of the calibration from the DUT characteristics. Our proposed architecture combines Planck spectroscopy using a Variable Temperature Stage with Short-Open-Load-Reciprocal scattering-parameter calibration, so that noise and scattering quantities are referred to the same cryogenic reference planes. In this configuration, the readout-chain calibration is separated from the internal dynamics of the DUT. As a demanding use case, we apply the protocol to a Josephson Traveling Wave Parametric Amplifier and extract its gain and input-referred added noise under pump conditions activating multimode nonlinear behavior. This illustrates how our device-agnostic protocol supports portable noise characterization of nonlinear cryogenic microwave devices.

quant-ph

Full Two-Port S-Parameters at mK Temperatures: a Calibration Strategy and Uncertainty Budget

This paper describes the developed setup and characterization approach for full two-port calibrated S-parameter measurements at cryogenic temperatures, together with a complete uncertainty budget. The system developed at the Istituto Nazionale di Ricerca Metrologica (INRiM, Italy), exploits the Short-Open-Load-Reciprocal technique to realize error-corrected cryogenic measurements within a single cooling cycle. The system operates down to mK temperatures over the 4-12 GHz band in coaxial line. Calibration standards are referenced to SI-traceable room-temperature measurements, while a numerical approach is used to evaluate the response shift of the artifacts upon cooling and to derive an additional cryogenic uncertainty contribution for the measurement uncertainty budget. Moreover, relevant measurement uncertainty contributions are evaluated according to internationally agreed procedures, and a comprehensive uncertainty budget is presented. Test measurements on a 20 dB attenuator are shown as an example. An attenuation of 20.70 +/- 0.08 dB (95% confidence interval) was obtained at 6 GHz. Full SI-traceable verification at mK temperatures remains an open challenge; however, an initial calibration verification is also presented.

physics.ins-det

Towards Quantifying Two-Mode Correlation Linewidths in Quantum Circuits

This paper aims to quantify the linewidth of two-mode correlations in Traveling Wave Parametric Amplifiers (TWPAs). Artifacts induced by data acquisition and processing, such as windowing effects and acquisition time, are examined to understand their influence on the linewidth estimation of these correlations. The findings underscore the significance of acquisition parameters in optimizing two-mode correlation measurements, enhancing device characterization for quantum applications.

quant-ph

Nonlinear Behavior of Josephson Traveling Wave Parametric Amplifiers

Recent advancements in quantum technologies and advanced detection experiments have underscored the pressing need for the detection of exceedingly weak signals within the microwave frequency spectrum. Addressing this challenge, the Josephson Traveling Wave Parametric Amplifier (JTWPA) has been proposed as a cryogenic front-end amplifier capable of approaching the quantum noise limit while providing a relevant bandwidth. This research is centered on a comprehensive numerical investigation of the JTWPA, without resorting to simplifications regarding the nonlinearity of the essential components. Specifically, this study focuses on a thorough examination of the system, characterized by coupled nonlinear differential equations representing all components of the device. Proper input and output signals at the device's boundaries are considered. The analysis of the output signals undergoing the parametric amplification process involves a detailed exploration of phase-space dynamics and Fourier spectral analysis of the output voltage. This study is conducted while considering the parameters ruling the response of the device under pump and signal excitations. In addition to the expected signal amplification, the findings reveal that the nonlinear nature of the system can give rise to unforeseen phenomena, depending on the system's operational conditions, which include: the generation of pump tone harmonics, modulation of the signal gain, and incommensurate frequency generation-effects that are not easily accommodated by simplistic linearized approaches

cond-mat.supr-con

Broadband parametric amplification in DARTWARS

Superconducting parametric amplifiers offer the capability to amplify feeble signals with extremely low levels of added noise, potentially reaching quantum-limited amplification. This characteristic makes them essential components in the realm of high-fidelity quantum computing and serves to propel advancements in the field of quantum sensing. In particular, Traveling-Wave Parametric Amplifiers (TWPAs) may be especially suitable for practical applications due to their multi-Gigahertz amplification bandwidth, a feature lacking in Josephson Parametric Amplifiers (JPAs), despite the latter being a more established technology. This paper presents recent developments of the DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project, focusing on the latest prototypes of Kinetic Inductance TWPAs (KITWPAs). The project aims to develop a KITWPA capable of achieving $20\,$ dB of amplification. To enhance the production yield, the first prototypes were fabricated with half the length and expected gain of the final device. In this paper, we present the results of the characterization of one of the half-length prototypes. The measurements revealed an average amplification of approximately $9\,$dB across a $2\,$GHz bandwidth for a KITWPA spanning $17\,$mm in length.

quant-ph

Development of KI-TWPAs for the DARTWARS project

Noise at the quantum limit over a broad bandwidth is a fundamental requirement for future cryogenic experiments for neutrino mass measurements, dark matter searches and Cosmic Microwave Background (CMB) measurements as well as for fast high-fidelity read-out of superconducting qubits. In the last years, Josephson Parametric Amplifiers (JPA) have demonstrated noise levels close to the quantum limit, but due to their narrow bandwidth, only few detectors or qubits per line can be read out in parallel. An alternative and innovative solution is based on superconducting parametric amplification exploiting the travelling-wave concept. Within the DARTWARS (Detector Array Readout with Travelling Wave AmplifieRS) project, we develop Kinetic Inductance Travelling-Wave Parametric Amplifiers (KI-TWPAs) for low temperature detectors and qubit read-out. KI-TWPAs are typically operated in a threewave mixing (3WM) mode and are characterised by a high gain, a high saturation power, a large amplification bandwidth and nearly quantum limited noise performance. The goal of the DARTWARS project is to optimise the KI-TWPA design, explore new materials, and investigate alternative fabrication processes in order to enhance the overall performance of the amplifier. In this contribution we present the advancements made by the DARTWARS collaboration to produce a working prototype of a KI-TWPA, from the fabrication to the characterisation.

quant-ph

Status of the SIMP Project: Toward the Single Microwave Photon Detection

The Italian institute for nuclear physics (INFN) has financed the SIMP project (2019-2021) in order to strengthen its skills and technologies in the field of meV detectors with the ultimate aim of developing a single microwave photon detector. This goal will be pursued by improving the sensitivity and the dark count rate of two types of photodetectors: current biased Josephson Junction (JJ) for the frequency range 10-50 GHz and Transition Edge Sensor (TES) for the frequency range 30-100 GHz. Preliminary results on materials and devices characterization are presented.

physics.ins-det

Identification of RF&MW microcalorimeter weak points by means of uncertainty analysis

Microcalorimeters are used by National Metrology Institutes (NMI) for the realization of the Radiofrequency and Microwaves (RF&MW) primary power standard. Since they are not available on the market, NMIs have to design their own systems. It involves the design of complex mechanical structures and of low noise data acquisition systems. Resulting setups allow precision measurements of RF&MW power by applying difficult and time consuming measurement techniques. Weaknesses to be addressed in order to improve the performance, whether in the mechanical structure or in the data acquisition electronics, are not easy to identify. Anyway, they can be found by analyzing the microcalorimeter measurement uncertainty. In recent years, several improvements have been made on the INRIM (Istituto Nazionale di Ricerca Metrologica, Italy) coaxial microcalorimeter with the aim of making its operation more stable and to reduce the measurement uncertainty. Its weak points are here analyzed by means of a comprehensive uncertainty budget. Details are also given on how uncertainty contributions have been determined. The method here applied is general and can be conveniently used in many other fields or applications provided that the analytical model is known. It is useful while designing an experiment and/or a posteriori, to identify the parts of the apparatus and of the measurement set-up that need to be optimized.

physics.ins-det

Alternative Procedures in Realizing of the High Frequency Power Standards with Microcalorimeter and Thermoelectric Power Sensors

The paper describes the realization process of the high frequency power standard based on a twin broadband microcalorimeter designed for effective efficiency measurement of coaxial power sensors with indirect heating thermocouples. The presented procedures involve microcalorimeter measurement and calibration steps, parameters computation and systematic errors correction for both long-term and accelerated algorithms. Also, a new method for determining the key parameters of high frequency power standards is proposed.

physics.ins-det

Improvement of primary power standard through international comparison feedback

The high frequency primary power standard is univocally realized by means of a coaxial microcalorimeter, at least up to 40 GHz. The coaxial microcalorimeter is a broadband measurement system adjusted for effec-tive efficiency measurement of power sensors both of bolometric and thermoelectric type. The critical point in the power standard realization is in the determination of the calibration constant g of the microcalorimeter, a frequency dependent parameter that has huge impact on the accuracy as-sessment of the standard. The paper proposes a simple but powerful way for improving this accuracy by using the reference values provided by in-ternational key-comparisons which the microcalorimeter was involved in.

physics.ins-det

Comparison between Thermoelectric and Bolometric Microwave Power Standards

In the paper, a comparison is described of the microwave power standard based on thermoelectric sensors against an analogous standard based on bolometric sensors. Measurements have been carried out with the classical twin-type microcalorimeter, fitted with N-connector test ports suitable for the frequency band 0.05 - 18 GHz. An appropriate measurand definition is given for being suitable to both standard types. A system accuracy assessment is performed applying the Gaussian error propagation through the mathematical models that interpret the microcalorimeter response in each case. The results highlight advantages and weaknesses of each power standard type.

physics.ins-det

Uncertainty Analysis for Material Measurements Using the Vector Network Analyzer

This paper presents the characterization measurements and related uncertainty evaluation of a nonmagnetic material using the Vector Network Analyzer (VNA) at microwave frequencies. The permittivity of the material under test is computed from the scattering parameters (S-parameters). The aim of the work is to highlight the different uncertainty contributions affecting the permittivity.

physics.app-ph

Improvements on INRIM Coaxial Microcalorimeter and Outcome of a Model Comparison

This paper describes hardware and software improvements of the INRIM coaxial microcalorimeter together with their outcome on the primary power standard realization in the frequency band 0.05 - 40 GHz. A better temperature and power stabilization turned out to provide an improved signal/noise ratio and a drift reduction in every working condition of the microcalorimeter. The INRIM correction model is also compared to a traditional, but faster, one in terms of measurement uncertainty. Outcomes are presented in form of a 2.92 mm thermoelectric power sensor calibration together with results that show the improved stability and repeatability of the measurement system.

physics.ins-det

RF/MW power standard realization without unitary efficiency assumption at dc/LF

Thermoelectric power sensors are widely used in commercial power meters at RF and microwaves, due to their superior robustness, stability, and accuracy if compared with other types of power sensors. Furthermore, their electrical architecture and related performance turned out to be very useful in the realization of the broadband primary power standards as alternative to resistive power sensors, i.e. bolometers. Hereby we present a comparison in term of effective efficiency of a thermoelectric sensor calibrated by applying two different methods of power substitution when used as thermal load in a coaxial microcalorimeter at RF and microwaves. The aim is to test a technology that could enable the realization of a primary RF/MW power standard independently of the assumption of unitary efficiency at the dc (or LF) reference power.

physics.ins-det

The True-Twin microcalorimeter: a proof-of-concept experiment

We present a proof-of-concept experiment to realize microwave primary power standard with a true-twin microcalorimeter. Double feeding line microcalorimeters are widely used by National Metrology Institutes. A drawback concerns the system calibration: traditional processes changes measurement conditions between system characterization and the measurement stage. Nevertheless, if the feeding lines are made twin, a measurement scheme that avoids separate characterization can be applied, equations simplify and time consumption is halved. Here we demonstrates the feasibility of the idea. The result of an effective efficiency spectroscopy of a thermoelectric power sensor is compared with figures obtained with well established methods.

physics.ins-det