Picosecond laser test unit for photosensor characterization at ambient and low temperatures

Accurate single photoelectron (SPE) characterization of photosensors is essential for controlling systematic uncertainties in low-light neutrino and dark matter detectors. We present a compact laboratory setup for the characterization of photosensors under controlled, low-light conditions. Specifically, we demonstrate its use with photomultiplier tubes (PMTs) operated at the SPE-level, using picosecond laser pulses and waveform digitization to determine key PMT properties. Measurements as a function of supply voltage and temperature ($-50^\circ$C to $+20^\circ$C) are performed on ET Enterprises 9821(Q)B tubes and a Hamamatsu R9980 assembly, which show exponential gain-voltage behavior and device-to-device variation. Cooling increases the gain by $\sim 0.1\,\%/^\circ$C, while the transit time spread (TTS) and peak-to-valley ratio (P/V) exhibit no clear temperature dependence. TTS decreases with voltage. Late pulses remain at the percent level and prepulses at the sub-percent level. Cable length affects both apparent gain and TTS. A model-independent, data-driven self-convolution method is introduced to quantify double photoelectron contributions from pulse charge spectra. The procedures provide a reproducible, practice-oriented reference for SPE-level PMT characterization and can be extended to other photosensor types.

physics.ins-det

PALM -- Precision Attenuation Length Measurement in Liquid Scintillators

Future neutrino experiments at low energies such as JUNO or THEIA will use large volume homogeneous liquid scintillator detectors. The optical attenuation length of the liquid is of uttermost importance for the successful realization of these experiments. At TU Munich a new optical spectrometer (Precision Attenuation Length Measurement (PALM)) has been set up in order to measure the light attenuation of liquids which can be used for these types of experiments up to around 100 m in the wavelength region between 400 nm and 1000 nm. The setup features an optical imaging system with a long focal length, which allows for in-situ monitoring of the beam stability during the measurement. The setup capability as well as the reproducibility of its results has been demonstrated at two different wavelengths of 430 nm and 500 nm.

physics.ins-det