Searcharxiv⌕ Search

arXiv subjects

Ludovic Bellon

Publications and source records attributed to Ludovic Bellon.

52 records · Page 3Linked to original sources

Resonance frequency shift of strongly heated micro-cantilevers

In optical detection setups to measure the deflection of micro-cantilevers, part of the sensing light is absorbed, heating the mechanical probe. We present experimental evidences of a frequency shift of the resonant modes of a cantilever when the light power of the optical measurement set-up is increased. This frequency shift is a signature of the temperature rise, and presents a dependence on the mode number. An analytical model is derived to take into account the temperature profile along the cantilever, it shows that the frequency shifts are given by an average of the profile weighted by the local curvature for each resonant mode. We apply this framework to measurements in vacuum and demonstrate that huge temperatures can be reached with moderate light intensities: a thousand {\textdegree}C with little more than 10 mW. We finally present some insight into the physical phenomena when the cantilever is in air instead of vacuum.

physics.ins-det↗

Simultaneous and accurate measurement of the dielectric constant at many frequencies spanning a wide range

We present an innovative technique which allows the simultaneous measurement of the dielectric constant of a material at many frequencies, spanning a four orders of magnitude range chosen between 10 --2 Hz and 10 4 Hz. The sensitivity and accuracy are comparable to those obtained using standard single frequency techniques. The technique is based on three new and simple features: a) the precise real time correction of the amplication of a current amplier; b) the specic shape of the excitation signal and its frequency spectrum; and c) the precise synchronization between the generation of the excitation signal and the acquisition of the dielectric response signal. This technique is useful in the case of relatively fast dynamical measurements when the knowledge of the time evolution of the dielectric constant is needed.

physics.ins-det↗

Adhesion energy of single wall carbon nanotube loops on various substrates

The physics of adhesion of one-dimensional nano structures such as nanotubes, nano wires, and biopolymers on different material substrates is of great interest for the study of biological adhesion and the development of nano electronics and nano mechanics. In this paper, we present force spectroscopy experiments of a single wall carbon nanotube loop using our home-made interferometric atomic force microscope. Characteristic force plateaux during the peeling process allows us to access to quantitative values of the adhesion energy per unit length on various substrates: graphite, mica, platinum, gold and silicon. By combining a time-frequency analysis of the deflexion of the cantilever, we access to the dynamic stiffness of the contact, providing more information on the nanotube configurations and its intrinsic mechanical properties.

cond-mat.mtrl-sci↗

Measurements of mechanical thermal noise and energy dissipation in optical dielectric coatings

In recent years an increasing number of devices and experiments are shown to be limited by mechanical thermal noise. In particular sub-Hertz laser frequency stabilization and gravitational wave detectors, that are able to measure fluctuations of 1E-18 m/rtHz or less, are being limited by thermal noise in the dielectric coatings deposited on mirrors. In this paper we present a new measurement of thermal noise in low absorption dielectric coatings deposited on micro-cantilevers and we compare it with the results obtained from the mechanical loss measurements. The coating thermal noise is measured on the widest range of frequencies with the highest signal to noise ratio ever achieved. In addition we present a novel technique to deduce the coating mechanical losses from the measurement of the mechanical quality factor which does not rely on the knowledge of the coating and substrate Young moduli. The dielectric coatings are deposited by ion beam sputtering. The results presented here give a frequency independent loss angle of (4.70 $\pm$ 0.2)x1E-4 with a Young's modulus of 118 GPa for annealed tantala from 10 Hz to 20 kHz. For as-deposited silica, a weak frequency dependence (~ f^{-0.025}) is observed in this frequency range, with a Young's modulus of 70 GPa and an internal damping of (6.0 $\pm$ 0.3)x1E-4 at 16 kHz, but this value decreases by one order of magnitude after annealing and the frequency dependence disappears.

physics.ins-det↗

Microrheology measurements with a hanging-fiber AFM probe

A method to measure the viscosity of liquids at microscales is presented. It uses a thin glass fiber fixed on the tip of the cantilever of an extremely low noise Atomic Force Microscope (AFM), which accurately measures the cantilever {deflection}. When the fiber is dipped into the liquid the dissipation of the cantilever-fiber system increases. This dissipation, linked to the liquid viscosity, is computed from the power spectral density of the thermal fluctuations of the cantilever {deflection}. The {high sensitivity of the AFM} allows us to show the existence and to develop a model of the coupling between the dynamics of the fiber and that of the cantilever. This model {accurately} fits the experimental data. The advantages and draw-backs of the method are discussed

cond-mat.soft↗

Quadrature phase interferometer for high resolution force spectroscopy

In this article, we present a deflection measurement setup for Atomic Force Microscopy (AFM). It is based on a quadrature phase differential interferometer: we measure the optical path difference between a laser beam reflecting above the cantilever tip and a reference beam reflecting on the static base of the sensor. A design with very low environmental susceptibility and another allowing calibrated measurements on a wide spectral range are described. Both enable a very high resolution (down to $\SI{2.5E-15}{m/\sqrt{Hz}}$), illustrated by thermal noise measurements on AFM cantilevers. They present an excellent long-term stability, and a constant sensitivity independent of the optical phase of the interferometer. A quick review shows that our precision is equaling or out-performing the best results reported in the literature, but for a much larger deflection range, up to a few $\SI{}{\micro m}$.

physics.ins-det↗

Functionalized AFM probes for force spectroscopy: eigenmodes shape and stiffness calibration through thermal noise measurements

The functionalization of an Atomic Force Microscope (AFM) cantilever with a colloidal bead is a widely used technique when the geometry between the probe and the sample must be controlled, particularly in force spectroscopy. But some questions remain: how does a bead glued at the end of a cantilever influence its mechanical response ? And more important for quantitative measurements, can we still determine the stiffness of the AFM probe with traditional techniques? In this article, the influence of a colloidal mass loading on the eigenmodes shape and resonant frequency is investigated by measuring the thermal noise on rectangular AFM microcantilevers with and without a bead attached at their extremities. The experiments are performed with a home-made ultra-sensitive AFM, based on differential interferometry. The focused beam from the interferometer probes the cantilever at different positions and the spatial shapes of the modes are determined up to the fifth resonance, without external excitation. The results clearly demonstrate that the first eigenmode almost doesn't change by mass loading. However the oscillation behavior of higher resonances present a marked difference: with a particle glued at its extremity, the nodes of the mode are displaced towards the free end of the cantilever. These results are compared to an analytical model taking into account the mass and the inertial moment of the load in an Euler-Bernoulli framework, where the normalization of the eigenmodes is explicitly worked out in order to allow a quantitative prediction of the thermal noise amplitude of each mode. A good agreement between the experimental results and the analytical model is demonstrated, allowing a clean calibration of the probe stiffness.

cond-mat.mes-hall↗

Dissipation of micro-cantilevers as a function of air pressure and metallic coating

In this letter, we characterize the internal dissipation of coated micro-cantilevers through their mechanical thermal noise. Using a home-made interferometric setup, we achieve a resolution down to 1E-14m/rtHz in the measurement of their deflection. With the use of the fluctuation dissipation theorem and of the Kramers-Kronig relations, we rebuilt the full mechanical response function from the measured noise spectrum, and investigate frequency dependent dissipation as a function of the air pressure and of the nature of the metallic coatings. Using different thicknesses of gold coatings, we discuss the source of the internal viscoelastic damping.

cond-mat.mtrl-sci↗

Carbon nanotubes adhesion and nanomechanical behavior from peeling force spectroscopy

Applications based on Single Walled Carbon Nanotube (SWNT) are good example of the great need to continuously develop metrology methods in the field of nanotechnology. Contact and interface properties are key parameters that determine the efficiency of SWNT functionalized nanomaterials and nanodevices. In this work we have taken advantage of a good control of the SWNT growth processes at an atomic force microscope (AFM) tip apex and the use of a low noise (1E-13 m/rtHz) AFM to investigate the mechanical behavior of a SWNT touching a surface. By simultaneously recording static and dynamic properties of SWNT, we show that the contact corresponds to a peeling geometry, and extract quantities such as adhesion energy per unit length, curvature and bending rigidity of the nanotube. A complete picture of the local shape of the SWNT and its mechanical behavior is provided.

cond-mat.mes-hall↗

Steady state fluctuation relations for systems driven by an external random force

We experimentally study the fluctuations of the work done by an external Gaussian random force on two different stochastic systems coupled to a thermal bath: a colloidal particle in an optical trap and an atomic force microscopy cantilever. We determine the corresponding probability density functions for different random forcing amplitudes ranging from a small fraction to several times the amplitude of the thermal noise. In both systems for sufficiently weak forcing amplitudes the work fluctuations satisfy the usual steady state fluctuation theorem. As the forcing amplitude drives the system far from equilibrium, deviations of the fluctuation theorem increase monotonically. The deviations can be recasted to a single master curve which only depends on the kind of stochastic external force.

cond-mat.stat-mech↗

Direct measurement of spatial modes of a micro-cantilever from thermal noise

Measurements of the deflection induced by thermal noise have been performed on a rectangular atomic force microscope cantilever in air. The detection method, based on polarization interferometry, can achieve a resolution of 1E-14 m/rtHz in the frequency range 1 kHz ? 800 kHz. The focused beam from the interferometer probes the cantilever at different positions along its length and the spatial modes' shapes are determined up to the fourth resonance, without external excitation. Results are in good agreement with theoretically expected behavior. From this analysis accurate determination of the elastic constant of the cantilever is also achieved.

cond-mat.stat-mech↗

Frequency dependence of viscous and viscoelastic dissipation in coated micro-cantilevers from noise measurement

We measure the mechanical thermal noise of soft silicon atomic force microscopy cantilevers. Using an interferometric setup, we have a resolution down to 1E-14 m/rtHz on a wide spectral range (3 Hz to 1E5 Hz). The low frequency behavior depends dramatically on the presence of a reflective coating: almost flat spectrums for uncoated cantilevers versus 1/f like trend for coated ones. The addition of a viscoelastic term in models of the mechanical system can account for this observation. Use of Kramers-Kronig relations validate this approach with a complete determination of the response of the cantilever: a power law with a small coefficient is found for the frequency dependence of viscoelasticity due to the coating, whereas the viscous damping due to the surrounding atmosphere is accurately described by the Sader model.

cond-mat.mtrl-sci↗

Thermal noise of microcantilevers in viscous fluids

We present a simple theoretical framework to describe the thermal noise of a microscopic mechanical beam in a viscous fluid: we use the Sader approach to describe the effect of the surrounding fluid (added mass and viscous drag), and the fluctuation dissipation theorem for each flexural modes of the system to derive a general expression for the power spectrum density of fluctuations. This prediction is compared with an experimental measurement on a commercial atomic force microscopy cantilever in a frequency range covering the two first resonances. A very good agreement is found on the whole spectrum, with no adjustable parameters but the thickness of the cantilever.

physics.class-ph↗

Single beam interferometric angle measurement

We present an application of a quadrature phase interferometer to the measurement of the angular position of a parallel laser beam with interferometric precision. In our experimental realization we reach a resolution of 6.8e-10 rad (1.4e-4 arcsec) for 1 kHz bandwidth in a 2e-2 rad (1 deg) range. This alternative to the optical lever technique features absolute calibration, independence of the sensitivity on the thermal drifts, and wide range of measurement at full accuracy.

physics.ins-det↗

Coupling between aging and convective motion in a colloidal glass of Laponite

We study thermal convection in a colloidal glass of Laponite in formation. Low concentration preparation are submitted to destabilizing vertical temperature gradient, and present a gradual transition from a turbulent convective state to a steady conductive state as their viscosity increases. The time spent under convection is found to depend strongly on sample concentration, decreasing exponentially with mass fraction of colloidal particles. Moreover, at fixed concentration, it also depends slightly on the pattern selected by the Rayleigh Bénard instability: more rolls maintain the convection state longer. This behavior can be interpreted with recent theoretical approaches of soft glassy material rheology.

cond-mat.soft↗

Experimental study of the Fluctuation-Dissipation-Relation during an aging process

The validity of fluctuation dissipation relations in an aging system is studied in a colloidal glass during the transition from a fluid-like to a solid-like state. The evolution of the rheological and electrical properties is analyzed in the range $1Hz - 40Hz$. It is found that at the beginning of the transition the fluctuation dissipation relation is strongly violated in electrical measurements. The amplitude and the persistence time of this violation are decreasing functions of frequency. At the lowest frequencies of the measuring range it persists for times which are about 5% of the time needed to form the colloidal glass. This phenomenology is quite close to the recent theoretical predictions done for the violation of the fluctuation dissipation relation in glassy systems. In contrast in the rheological measurements no violation of the fluctuation dissipation relation is observed. The reasons of this large difference between the electrical and rheological measurements are discussed.

cond-mat.mtrl-sci↗