SearcharxivSearch

arXiv subjects

Ludovico Luzzi

Publications and source records attributed to Ludovico Luzzi.

2 recordsLinked to original sources

High-Voltage Performance Testing in LAr of the PMMA Cathode Connection for the DarkSide-20k Experiment

DarkSide-20k (DS-20k) is a next-generation dual-phase liquid argon (LAr) time projection chamber (TPC) devoted to the direct-detection of dark matter. The detector is currently under construction in Hall-C at the Laboratori Nazionali del Gran Sasso, Italy, at a depth of approximately 3500 m water equivalent. The detector will instrument 49.7 t of low-radioactivity underground LAr contained within an acrylic TPC and is designed to reach a WIMP-nucleon spin-independent cross-section sensitivity down to $10^{-48}\,\mathrm{cm}^{2}$ for a WIMP mass of $0.1\,\mathrm{TeV}/c^{2}$ in a 200 tonne-year run. In DS-20k a uniform electric drift field is established in the active volume to transport ionization electrons toward the electroluminescence region, with the required high voltage delivered to the TPC cathode through a custom cable and stress-cone assembly. At the University of California, Davis, a dedicated test setup was developed to reproduce the DS-20k cathode high-voltage connection in LAr, matching the local electric-field conditions. This work summarizes the results of a comprehensive test campaign validating the operation of the DS-20k cathode HV system in LAr up to $-100$ kV.

physics.ins-det

Study of the energy calibration of the DEAP-3600 detector using $^{22}\mathrm{Na}$ source data and simulations

DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3.3 tons of LAr contained in a spherical acrylic vessel. At a WIMP mass of 100 GeV, DEAP-3600 has a projected sensitivity of $10^{-46}\,\mathrm{cm}^{2}$ for the spin-independent elastic scattering cross section of WIMPs. Radioactive sources have been used for the energy calibration and to test the detector performance. One of the most effective calibration runs has been taken with a $^{22}\mathrm{Na}$ source deployed in a tube located around the DEAP-3600 steel shell. The simultaneous emission of three $\gamma$'s by the source provides an excellent tagging for the $^{22}\mathrm{Na}$ decay. The results concerning the energy response of the detector and the agreement between data and Monte Carlo simulations in DEAP-3600 are investigated in this study.

physics.ins-det