SearcharxivSearch

arXiv subjects

Luis Delgadillo Franco

Publications and source records attributed to Luis Delgadillo Franco.

3 recordsLinked to original sources

Final assessment of radioactive impurities in the JUNO detector

The Jiangmen Underground Neutrino Observatory (JUNO) collaboration has completed the construction of the 20,000-ton liquid scintillator detector and the associated muon veto detector system. To meet the physics objectives, the materials used in the detector must exhibit low radioactive contamination. The single-event rate in the fiducial volume (R $<$ 17.2 m) of the scintillator is required to be approximately 7 Hz for energies above 0.7 MeV, resulting in an accidental coincidence background of about 1 event per day for reactor neutrino physics analyses. Since the beginning of the construction phase, we have screened the natural radioactivity content of thousands of materials, to select those that meet the design background budget. The radioactive impurity concentrations of the materials ultimately used in the JUNO detector are summarized in this paper. The construction of the entire detector and the subsequent filling of the liquid scintillator were completed in August 2025. From the initial data, the total count rate of natural radioactivity within the detector's fiducial volume has met the requirements and is sufficient to support the reactor antineutrino analysis.

physics.ins-det

A Low-energy Threshold and Multi-messenger Trigger System for the JUNO Experiment

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20-kiloton liquid scintillator neutrino detector, located 650 meters (1800 m.w.e.) underground in Jiangmen, Guangdong, China. JUNO is primarily designed for reactor neutrino measurements and has been taking data since 2025. With the largest mass of its kind and an excellent energy resolution, JUNO is a leading observatory for high-precision measurements of MeV neutrinos. The standard global trigger system serves as the primary trigger for JUNO. We present a newly developed multi-messenger trigger system that extends the capabilities of the global trigger by providing a lower energy threshold and an independent monitoring capability. During the 2025 operation, it achieved an effective energy threshold of approximately 110 +/- 10 keV, providing a lower threshold configuration suitable for low-energy event analysis. The system shows the potential to further reduce the threshold to well below 100 keV. Based on the multi-messenger trigger system, an astrophysical monitor has been developed to receive and process external alerts from other messengers, such as gravitational-wave observations. A Transient Neutrino Burst Monitor is integrated to detect short-time-scale neutrino burst events and enables real-time monitoring of transient astrophysical phenomena. The system is sensitive to neutrino bursts from core-collapse supernovae within a distance of about 250 kpc.

hep-ex

Embedded underwater front-end electronics for the 3-inch photomultipliers in the JUNO experiment

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20-kton liquid scintillator-based, low-radioactivity, multi-purpose neutrino detector located 693 meters (1800 m.w.e.) underground in the Guangdong province, China. To detect scintillation light produced in the target, the detector is equipped with 17,612 20-inch photomultipliers (PMTs), forming the Large PMT system (LPMT). In addition, 25,600 3-inch photomultipliers (the Small Photomultiplier System or SPMT) are deployed in the gaps between the LPMTs. This paper presents the design and performance of the underwater front-end electronics developed for the SPMT system. It details the individual electronics boards and their key components, the inter-board interfaces, the system-level design, and the firmware architecture that supports data acquisition and control. It also outlines mechanical and thermal integration, board validation procedures, and system performance metrics. The readout chain includes digitization of 128 PMT channels per unit, synchronized time-stamping, charge measurement, event packaging, and bandwidth management. Comprehensive validation confirms the system's readiness to meet JUNO's stringent physics goals. The underwater electronics achieve noise levels as low as 0.04 photoelectrons with minimal crosstalk (below 0.4%) and a bandwidth of 57 MB/s, ensuring reliable single photo-electron detection and operation under high-rate conditions. The SPMT system has now been fully integrated and installed in JUNO. Its commissioning and physics performance will be reported in a future publication.

physics.ins-det