Searcharxiv⌕ Search

arXiv subjects

Luisa Gallée

Publications and source records attributed to Luisa Gallée.

6 recordsLinked to original sources

Towards Practical Algorithm Selection for Unsupervised Domain Adaptation in Medical Imaging

Numerous unsupervised domain adaptation (UDA) algorithms exist, but for clinical practice, selecting the best-suited one along with proper hyperparameters often remains unclear, as the unlabeled deployment (target) domain prevents direct evaluation. We propose a label-free criterion that jointly selects the algorithm and hyperparameters for UDA. Given a pool of candidate models from multiple algorithms trained with different hyperparameters, our approach scores each candidate against an agreement reference, and selects the one with the highest score. The agreement reference is constructed in two levels without using target labels. First, we leverage multiple label-free selection signals, using each to nominate a model within every algorithm. Second, the nominated models are aggregated across algorithms to form a reference prediction for each unlabeled target sample. The candidate whose predictions agree most with this reference is then selected for deployment. Experimental results on four brain MRI and four chest X-ray datasets across seven clinically relevant transfer scenarios show that our method achieves better selection performance than other methods and remains effective across different algorithm pools. Our approach takes a step towards practical, label-free algorithm selection for clinical deployment of UDA.

cs.CV↗

How Far from Clinical Deployment? Evaluating the Complete Unsupervised Domain Adaptation Pipeline in Medical Imaging

Deploying unsupervised domain adaptation (UDA) in clinical practice requires choosing which algorithm to use and which of its trained models to ship. However, the deployment (target) domain is unlabeled, so models cannot be evaluated directly on it, leaving it unclear which to select. We address this by evaluating the complete UDA pipeline, considering both adaptation and label-free selection together. Our study covers eleven clinically relevant cross-domain scenarios from nine medical imaging datasets, with ten UDA algorithms and 13 label-free selection methods (validators), evaluating over 80,000 trained models in total. By this, we find that a capable adapted model usually exists, but identifying it without target labels is difficult: the validator-selected models leave a large and structural target performance gap to the best available one, with no evaluated validator consistently reliable. Towards closing it, we explore two strategies, ensembling and a small target-labeling budget; both narrow this gap but do not close it entirely. Overall, deployable UDA depends on the complete pipeline; addressing the less explored selection step could bring much of current UDA closer to clinical use.

cs.CV↗

FunnyNodules: A Customizable Medical Dataset Tailored for Evaluating Explainable AI

Densely annotated medical image datasets that capture not only diagnostic labels but also the underlying reasoning behind these diagnoses are scarce. Such reasoning-related annotations are essential for developing and evaluating explainable AI (xAI) models that reason similarly to radiologists: making correct predictions for the right reasons. To address this gap, we introduce FunnyNodules, a fully parameterized synthetic dataset designed for systematic analysis of attribute-based reasoning in medical AI models. The dataset generates abstract, lung nodule-like shapes with controllable visual attributes such as roundness, margin sharpness, and spiculation. The target class is derived from a predefined attribute combination, allowing full control over the decision rule that links attributes to the diagnostic class. We demonstrate how FunnyNodules can be used in model-agnostic evaluations to assess whether models learn correct attribute-target relations, to interpret over- or underperformance in attribute prediction, and to analyze attention alignment with attribute-specific regions of interest. The framework is fully customizable, supporting variations in dataset complexity, target definitions, class balance, and beyond. With complete ground truth information, FunnyNodules provides a versatile foundation for developing, benchmarking, and conducting in-depth analyses of explainable AI methods in medical image analysis.

cs.CV↗

Minimum Data, Maximum Impact: 20 annotated samples for explainable lung nodule classification

Classification models that provide human-interpretable explanations enhance clinicians' trust and usability in medical image diagnosis. One research focus is the integration and prediction of pathology-related visual attributes used by radiologists alongside the diagnosis, aligning AI decision-making with clinical reasoning. Radiologists use attributes like shape and texture as established diagnostic criteria and mirroring these in AI decision-making both enhances transparency and enables explicit validation of model outputs. However, the adoption of such models is limited by the scarcity of large-scale medical image datasets annotated with these attributes. To address this challenge, we propose synthesizing attribute-annotated data using a generative model. We enhance the Diffusion Model with attribute conditioning and train it using only 20 attribute-labeled lung nodule samples from the LIDC-IDRI dataset. Incorporating its generated images into the training of an explainable model boosts performance, increasing attribute prediction accuracy by 13.4% and target prediction accuracy by 1.8% compared to training with only the small real attribute-annotated dataset. This work highlights the potential of synthetic data to overcome dataset limitations, enhancing the applicability of explainable models in medical image analysis.

cs.CV↗

Hierarchical Vision Transformer with Prototypes for Interpretable Medical Image Classification

Explainability is a highly demanded requirement for applications in high-risk areas such as medicine. Vision Transformers have mainly been limited to attention extraction to provide insight into the model's reasoning. Our approach combines the high performance of Vision Transformers with the introduction of new explainability capabilities. We present HierViT, a Vision Transformer that is inherently interpretable and adapts its reasoning to that of humans. A hierarchical structure is used to process domain-specific features for prediction. It is interpretable by design, as it derives the target output with human-defined features that are visualized by exemplary images (prototypes). By incorporating domain knowledge about these decisive features, the reasoning is semantically similar to human reasoning and therefore intuitive. Moreover, attention heatmaps visualize the crucial regions for identifying each feature, thereby providing HierViT with a versatile tool for validating predictions. Evaluated on two medical benchmark datasets, LIDC-IDRI for lung nodule assessment and derm7pt for skin lesion classification, HierViT achieves superior and comparable prediction accuracy, respectively, while offering explanations that align with human reasoning.

cs.CV↗

Evaluating the Explainability of Attributes and Prototypes for a Medical Classification Model

Due to the sensitive nature of medicine, it is particularly important and highly demanded that AI methods are explainable. This need has been recognised and there is great research interest in xAI solutions with medical applications. However, there is a lack of user-centred evaluation regarding the actual impact of the explanations. We evaluate attribute- and prototype-based explanations with the Proto-Caps model. This xAI model reasons the target classification with human-defined visual features of the target object in the form of scores and attribute-specific prototypes. The model thus provides a multimodal explanation that is intuitively understandable to humans thanks to predefined attributes. A user study involving six radiologists shows that the explanations are subjectivly perceived as helpful, as they reflect their decision-making process. The results of the model are considered a second opinion that radiologists can discuss using the model's explanations. However, it was shown that the inclusion and increased magnitude of model explanations objectively can increase confidence in the model's predictions when the model is incorrect. We can conclude that attribute scores and visual prototypes enhance confidence in the model. However, additional development and repeated user studies are needed to tailor the explanation to the respective use case.

cs.CV↗