Benchmarking CNN-based Models against Transformer-based Models for Abdominal Multi-Organ Segmentation on the RATIC Dataset

Accurate multi-organ segmentation in abdominal CT scans is essential for computer-aided diagnosis and treatment. While convolutional neural networks (CNNs) have long been the standard approach in medical image segmentation, transformer-based architectures have recently gained attention due to their ability to model long-range dependencies. In this study, we systematically benchmark the three hybrid transformer-based models UNETR, SwinUNETR, and UNETR++ against a strong CNN baseline, SegResNet, for volumetric multi-organ segmentation on the heterogeneous RATIC dataset. The dataset comprises 206 annotated CT scans from 23 institutions worldwide, covering five abdominal organs. All models were trained and evaluated under identical preprocessing and training conditions using the Dice Similarity Coefficient (DSC) as the primary metric. The results show that the CNN-based SegResNet achieves the highest overall performance, outperforming all hybrid transformer-based models across all organs. Among the transformer-based approaches, UNETR++ delivers the most competitive results, while UNETR demonstrates notably faster convergence with fewer training iterations. These findings suggest that, for small- to medium-sized heterogeneous datasets, well-optimized CNN architectures remain highly competitive and may outperform hybrid transformer-based designs.

cs.CV

Quality Concerns Caused by Quality Control -- deformation of silicon strip detector modules in thermal cycling tests

The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with the upgraded, all-silicon Inner Tracker (ITk) for its High-Luminosity upgrade (HL-LHC). The ITk will consist of a central pixel tracker and the outer strip tracker, consisting of about 19,000 strip detector modules. Each strip module is assembled from up to two sensors, and up to five flexes (depending on its geometry) in a series of gluing, wirebonding and quality control steps. During detector operation, modules will be cooled down to temperatures of about -35C (corresponding to the temperature of the support structures on which they will be mounted) after being initially assembled and stored at room temperature. In order to ensure compatibility with the detector's operating temperature range, modules are subjected to thermal cycling as part of their quality control process. Ten cycles between -35C and +40C are performed for each module, with full electrical characterisation tests at each high and low temperature point. As part of an investigation into the stress experienced by modules during cooling, it was observed that modules generally showed a change in module shape before and after thermal cycling. This paper presents a summary of the discovery and understanding of the observed changes, connecting them with excess module stress, as well as the resulting modifications to the module thermal cycling procedure.

hep-ex