SearcharxivSearch

arXiv subjects

Lukas Brand

Publications and source records attributed to Lukas Brand.

At least 19 recordsLinked to original sources

Multipath Channel Metrics and Detection in Vascular Molecular Communication: A Wireless-Inspired Perspective

Motivated by classical communications engineering, early works in molecular communication (MC) largely adopted established modeling and signal processing concepts from wireless electromagnetic communication systems. In the context of the human cardiovascular system (CVS), MC channel models evolved from simple unbounded and single-duct environments mimicking individual blood vessels to complex vessel network (VN) topologies, generally at the expense of analytical tractability. Up until now, this has largely prohibited rigorous communication-theoretic analysis of large-scale VNs. In this work, we leverage a recently established closed-form analytical channel model for VNs, named mixture of inverse Gaussians for hemodynamic transport (MIGHT), to conduct the first systematic communication-theoretic study of MC in complex, large-scale VNs. Based on MIGHT, we derive a Poisson channel noise model and unveil structural analogies between multipath wireless communications (MWC) and advective-diffusive MC in VNs. In particular, we establish classical MWC metrics, namely the root mean squared (RMS) delay spread, the mean excess delay, and the coherence bandwidth, for MC in VNs and derive closed-form expressions for the channel frequency response and power delay profile (PDP). Building on this characterization, we propose a VN-adapted, coherent decision-feedback (DF) detector and show how the derived multipath metrics can inform the choice of critical system parameters like the symbol duration, the sampling time, and the memory length. Additionally, we evaluate the detector's performance in different VNs exhibiting inter-symbol interference (ISI). Together, these contributions open the door to a systematic, MWC-inspired MC system design for large-scale VNs.

cs.IT

Vessel Network Topology in Molecular Communication: Insights from Experiments and Theory

The notion of synthetic molecular communication (MC) refers to the transmission of information via signaling molecules and is foreseen to enable innovative medical applications in the human cardiovascular system (CVS). Crucially, the design of such applications requires accurate and experimentally validated channel models that characterize the propagation of signaling molecules, not just in individual blood vessels, but in complex vessel networks (VNs), as prevalent in the CVS. However, experimentally validated models for MC in VNs remain scarce. To address this gap, we propose a novel channel model for MC in complex VN topologies, which captures molecular transport via advection, molecular and turbulent diffusion, as well as adsorption and desorption at the vessel walls. We specialize this model for superparamagnetic iron-oxide nanoparticles (SPIONs) as signaling molecules by introducing a new receiver (RX) model for planar coil inductive sensors, enabling end-to-end experimental validation with a dedicated SPION testbed. Validation covers a range of channel topologies, from single-vessel topologies to branched VNs with multiple paths between transmitter (TX) and RX. Additionally, to quantify how the VN topology impacts signal quality, and inspired by multi-path propagation models in conventional wireless communications, we introduce two metrics, namely molecule delay and multi-path spread. We show that these metrics link the VN structure to molecule dispersion induced by the VN and mediately to the resulting signal-to-noise ratio (SNR) at the RX. The proposed VN structure-SNR link is validated experimentally, demonstrating that the proposed framework can support tasks such as optimal sensor placement in the CVS or the identification of suitable testbed topologies for specific SNR requirements. All experimental data are openly available on Zenodo.

q-bio.QM

Modulation Schemes for Functionalized Vesicle-based MC Transmitters

Molecular communication (MC) enables information exchange through the transmission of signaling molecules (SMs) and holds promise for many innovative applications. However, most existing works in MC rely on simplified transmitter (TX) models that do not account for the physical and biochemical limitations of realistic biological hardware and environments. This work extends previous efforts toward developing models for practical MC systems by proposing a more realistic TX model that incorporates the delay in SM release and TX noise introduced by biological components. Building on this more realistic, functionalized vesicle-based TX model, we propose two novel modulation schemes specifically designed for this TX to mitigate TX-induced memory effects that arise from delayed and imperfectly controllable SM release. The proposed modulation schemes enable low-complexity receiver designs by mitigating memory effects directly at the TX. Numerical evaluations demonstrate that the proposed schemes improve communication reliability under realistic biochemical constraints, offering an important step toward physically realizable MC systems.

cs.ET

Molecular Communication for Gastroretentive Drug Delivery

Recently, bacterial nanocellulose (BNC), a biological material produced by non-pathogenic bacteria that possesses excellent material properties for various medical applications, has received increased interest as a carrier system for drug delivery. However, the vast majority of existing studies on drug release from BNC are feasibility studies with modeling and design aspects remaining largely unexplored. To narrow this research gap, this paper proposes a novel model for the drug release from BNC. Specifically, the drug delivery system considered in this paper consists of a BNC fleece coated with a polymer. The polymer coating is used as an additional diffusion barrier, enabling the controlled release of an active pharmaceutical ingredient. The proposed physics-based model reflects the geometry of the BNC and incorporates the impact of the polymer coating on the drug release. Hence, it can be useful for designing BNC-based drug delivery systems in the future. The accuracy of the model is validated with experimental data obtained in wet lab experiments.

eess.SP

Synthetic MC via Biological Transmitters: Therapeutic Modulation of the Gut-Brain Axis

Synthetic molecular communication (SMC) is a key enabler for future healthcare systems in which Internet of Bio-Nano-Things (IoBNT) devices facilitate the continuous monitoring of a patient's biochemical signals. To close the loop between sensing and actuation, both the detection and the generation of in-body molecular communication (MC) signals is key. However, generating signals inside the human body, e.g., via synthetic nanodevices, poses a challenge in SMC, due to technological obstacles as well as legal, safety, and ethical issues. Hence, this paper considers an SMC system in which signals are generated indirectly via the modulation of a natural in-body MC system, namely the gut-brain axis (GBA). Therapeutic GBA modulation is already established as treatment for neurological diseases, e.g., drug refractory epilepsy (DRE), and performed via the administration of nutritional supplements or specific diets. However, the molecular signaling pathways that mediate the effect of such treatments are mostly unknown. Consequently, existing treatments are standardized or designed heuristically and able to help only some patients while failing to help others. In this paper, we propose to leverage personal health data, e.g., gathered by in-body IoBNT devices, to design more versatile and robust GBA modulation-based treatments as compared to the existing ones. To show the feasibility of our approach, we define a catalog of theoretical requirements for therapeutic GBA modulation. Then, we propose a machine learning model to verify these requirements for practical scenarios when only limited data on the GBA modulation exists. By evaluating the proposed model on several datasets, we confirm its excellent accuracy in identifying different modulators of the GBA. Finally, we utilize the proposed model to identify specific modulatory pathways that play an important role for therapeutic GBA modulation.

cs.LG

Closed-Loop Molecular Communication with Local and Global Degradation: Modeling and ISI Analysis

This paper presents a novel physics-based model for signal propagation in closed-loop molecular communication (MC) systems, which are particularly relevant for many envisioned biomedical applications, such as health monitoring or drug delivery within the closed-loop human cardiovascular system (CVS). Compared to open-loop systems, which are mostly considered in MC, closed-loop systems exhibit different characteristic effects influencing signaling molecule (SM) propagation. One key phenomenon are the periodic SM arrivals at the receiver (RX), leading to various types of inter-symbol interference (ISI) inherent to closed-loop system. To capture these characteristic effects, we propose an analytical model for the SM propagation inside closed-loop systems. The model accounts for arbitrary spatio-temporal SM release patterns at the transmitter (TX), and incorporates several environmental effects such as fluid flow, SM diffusion, and SM degradation. Moreover, to capture a wide range of practically relevant degradation and clearance mechanisms, the model includes both local removal (e.g., due to SM absorption into organs) and global removal (e.g., due to chemical degradation) of SMs. The accuracy of the proposed model is validated with three-dimensional (3-D) particle-based simulations (PBSs). Moreover, we utilize the proposed model to develop a rigorous characterization of the various types of ISI encountered in closed-loop MC systems.

eess.SY

Closed-Loop Long-Term Experimental Molecular Communication System

We present a fluid-based experimental molecular communication (MC) testbed which uses media modulation. Motivated by the natural human cardiovascular system, the testbed operates in a closed-loop tube system. The proposed system is designed to be biocompatible, resource-efficient, and controllable from outside the tube. As signaling molecule, the testbed employs the green fluorescent protein variant "Dreiklang" (GFPD). GFPDs can be reversibly switched via light of different wavelengths between a bright fluorescent state and a less fluorescent state. GFPDs in solution are filled into the testbed prior to the start of information transmission and remain there for an entire experiment. For information transmission, an optical transmitter (TX) and an optical eraser (EX), which are located outside the tube, are used to write and erase the information encoded in the state of the GFPDs, respectively. At the receiver (RX), the state of the GFPDs is read out by fluorescence detection. In our testbed, due to the closed-loop setup, we observe new forms of inter-symbol interferences (ISI), which do not occur in short experiments and open-loop systems. For the testbed, we developed a communication scheme, which includes blind transmission start detection, symbol-by-symbol synchronization, and adaptive threshold detection. We comprehensively analyze our MC experiments using different performance metrics. Moreover, we experimentally demonstrate the error-free transmission of 5370 bit at a data rate of 36 $\textrm{bit}\, \textrm{min}^{\boldsymbol{-1}}$ using 8-ary modulation and the error-free binary transmission of around 90000 bit at a data rate of 12 $\textrm{bit}\, \textrm{min}^{\boldsymbol{-1}}$. For the latter experiment, data was transmitted for a period of 125 hours. All signals recorded and parts of the evaluation code are publicly available on Zenodo and Github, respectively.

cs.ET

Molecular Signal Reception in Complex Vessel Networks: The Role of the Network Topology

The notion of synthetic molecular communication (MC) refers to the transmission of information via molecules and is largely foreseen for use within the human body, where traditional electromagnetic wave (EM)-based communication is impractical. MC is anticipated to enable innovative medical applications, such as early-stage tumor detection, targeted drug delivery, and holistic approaches like the Internet of Bio-Nano Things (IoBNT). Many of these applications involve parts of the human cardiovascular system (CVS), here referred to as networks, posing challenges for MC due to their complex, highly branched vessel structures. To gain a better understanding of how the topology of such branched vessel networks affects the reception of a molecular signal at a target location, e.g., the network outlet, we present a generic analytical end-to-end model that characterizes molecule propagation and reception in linear branched vessel networks (LBVNs). We specialize this generic model to any MC system employing superparamagnetic iron-oxide nanoparticles (SPIONs) as signaling molecules and a planar coil as receiver (RX). By considering components that have been previously established in testbeds, we effectively isolate the impact of the network topology and validate our theoretical model with testbed data. Additionally, we propose two metrics, namely the molecule delay and the multi-path spread, that relate the LBVN topology to the molecule dispersion induced by the network, thereby linking the network structure to the signal-to-noise ratio (SNR) at the target location. This allows the characterization of the SNR at any point in the network solely based on the network topology. Consequently, our framework can, e.g., be exploited for optimal sensor placement in the CVS or identification of suitable testbed topologies for given SNR requirements.

cs.ET

The Chorioallantoic Membrane Model: A 3D in vivo Testbed for Design and Analysis of MC Systems

Molecular Communications (MC) research is increasingly focused on applications within the human body, such as health monitoring and drug delivery. These applications require testing in realistic and living environments. Thus, advancing experimental MC research to the next level requires the development of in vivo experimental testbeds. In this paper, we introduce the Chorioallantoic Membrane ( CAM ) model as a versatile 3D in vivo MC testbed. The CAM is a highly vascularized membrane formed in fertilized chicken eggs and has gained significance in various research fields, including bioengineering, cancer research, and drug development. Its versatility, reproducibility, and realistic biological properties make the CAM model perfectly suited for next-generation MC testbeds, facilitating the transition from proof-of-concept systems to practical applications. We provide a comprehensive introduction to the CAM model, its properties, and its applications in practical research. Additionally, we present a characterization of the CAM model as an MC system. As a preliminary experimental study, we investigate the distribution of fluorescent molecules in the closed-loop vascular system of the CAM model. We also derive an approximate analytical model for the propagation of molecules in closed-loop systems, and show that the proposed model is able to approximate molecule propagation in the CAM model.

cs.ET

Practical Transmitters for Molecular Communication: Functionalized Nanodevices Employing Cooperative Transmembrane Transport Proteins

This paper introduces a novel optically controllable molecular communication (MC) transmitter (TX) design based on vesicular nanodevices (NDs). The NDs are functionalized for the controlled release of signaling molecules (SMs) via transmembrane proteins. The proposed design contributes to overcoming the current barrier between MC theory and practical implementation, as all components of the system are chemically realizable. The NDs possess an optical-to-chemical conversion capability, therefore, the proposed NDs can be employed as externally controllable TXs in various MC systems. The proposed ND design comprises two cooperating modules, namely an energizing module and a release module, and, depending on the specific choices for the modules, allows for the release of different types of SMs. After introducing the general system model for the proposed realistic TX design, we provide a detailed mathematical analysis of a specific TX realization. In particular, we derive both an exact and a closed-form approximate analytical solution for the concentration of the released SMs and validate our results by comparison with a numerical solution. Moreover, we model the impact of a buffering medium, which is typically present in liquid environments, e.g., in experimental settings or in in-body applications. This allows the evaluation of the feasibility of our proposed TX design in practical chemical implementations. We consider various forms of parameter randomness occurring during vesicle synthesis, i.e., deviations which are unavoidable during experiments. We show that considering random distributions of the parameter values, such as the ND size, the number of incorporated proteins on the vesicle surface, and the vesicle membrane permeability, is crucial for an adequate kinetic analysis of the system.

cs.ET

Semantic Information in MC: Chemotaxis Beyond Shannon

The recently emerged molecular communication (MC) paradigm intends to leverage communication engineering tools for the design of synthetic chemical communication systems. These systems are envisioned to operate at nanoscale and in biological environments, such as the human body, and catalyze the emergence of revolutionary applications in the context of early disease monitoring and drug targeting. Despite the abundance of theoretical (and recently also experimental) MC system designs proposed over the past years, some fundamental questions remain unresolved, hindering the breakthrough of MC in real-world applications. One of these questions is: What can be a useful measure of information in the context of MC applications? While most existing works on MC build upon the concept of syntactic information as introduced by Shannon, in this paper, we explore the framework of semantic information as introduced by Kolchinsky and Wolpert for the information-theoretic analysis of a natural MC system, namely bacterial chemotaxis. Exploiting computational agent-based modeling (ABM), we are able to quantify, for the first time, the amount of information that the considered chemotactic bacterium (CB) utilizes to adapt to and survive in a dynamic environment. In other words, we show how the flow of information between the environment and the CB is related to the effectiveness of communication. Effectiveness here refers to the adaptation of the CB to the dynamic environment in order to ensure survival. Our analysis reveals that it highly depends on the environmental conditions how much information the CB can effectively utilize for improving their survival chances. Encouraged by our results, we envision that the proposed semantic information framework can open new avenues for the development of theoretical and experimental MC system designs for future nanoscale applications.

cs.IT

Closing the Implementation Gap in MC: Fully Chemical Synchronization and Detection for Cellular Receivers

In the context of the Internet of Bio-Nano Things (IoBNT), nano-devices are envisioned to perform complex tasks collaboratively, i.e., by communicating with each other. One candidate for the implementation of such devices are engineered cells due to their inherent biocompatibility. However, because each engineered cell has only little computational capabilities, transmitter and receiver (RX) functionalities can afford only limited complexity. In this paper, we propose a simple, yet modular, architecture for a cellular RX that is capable of processing a stream of observed symbols using chemical reaction networks. Furthermore, we propose two specific detector implementations for the RX. The first detector is based on a machine learning model that is trained offline, i.e., before the cellular RX is deployed. The second detector utilizes pilot symbol-based training and is therefore able to continuously adapt to changing channel conditions online, i.e., after deployment. To coordinate the different chemical processing steps involved in symbol detection, the proposed cellular RX leverages an internal chemical timer. Furthermore, the RX is synchronized with the transmitter via external, i.e., extracellular, signals. Finally, the proposed architecture is validated using theoretical analysis and stochastic simulations. The presented results confirm the feasibility of both proposed implementations and reveal that the proposed online learning-based RX is able to perform reliable detection even in initially unknown or slowly changing channels. By its modular design and exclusively chemical implementation, the proposed RX contributes towards the realization of versatile and biocompatible nano-scale communication networks for IoBNT applications narrowing the existing implementation gap in cellular molecular communication (MC).

cs.ET

Closed Loop Molecular Communication Testbed: Setup, Interference Analysis, and Experimental Results

In this paper, we present a fluid-based experimental molecular communication (MC) testbed that, similar to the human cardiovascular system, operates in a closed circuit tube system. The proposed system is designed to be biocompatible, resource-efficient, and controllable from outside the tube. As signaling molecule, the testbed employs the green fluorescent protein variant "Dreiklang" (GFPD). GFPDs can be reversibly switched via light of different wavelengths between a bright fluorescent state and a less fluorescent state. Hence, this property allows for writing and erasing information encoded in the state of the GFPDs already present in the fluid via radiation from outside the tube. The concept of modulating the GFPDs existing in the channel at the transmitter for information transmission, instead of releasing new molecules, is a form of media modulation. In our testbed, due to the closed loop setup and the long experiment durations of up to 250 min, we observe new forms of inter-symbol interferences (ISI), which do not occur in short experiments and open loop systems. In particular, up to four different forms of ISI, namely channel ISI, inter-loop ISI, offset ISI, and permanent ISI, occur in the considered system. To mitigate inter-loop ISI and offset ISI, we propose a light based eraser unit. We experimentally demonstrate reliable information transmission in our testbed achieving error-free transmission of 500 bit at a data rate of 6 bit/min based on a sub-optimal low-complexity detection scheme.

cs.ET

Area Rate Efficiency in Multi-Link Molecular Communications

We consider a multi-link diffusion-based molecular communication (MC) system where multiple spatially distributed transmitter (TX)-receiver (RX) pairs establish point-to-point communication links employing the same type of signaling molecules. To exploit the full potential of such a system, an in-depth understanding of the interplay between the spatial link density and inter-link interference (ILI) and its impact on system performance is needed. In this paper, we consider a three-dimensional unbounded domain with multiple spatially distributed point-to-point non-cooperative transmission links, where both the TXs and RXs are positioned on a regular fixed grid. For this setup, we first derive an analytical expression for the channel impulse responses (CIRs) between the TXs and RXs in the system. Then, we derive the maximum likelihood (ML) detector for the RXs and show that it reduces to a threshold-based detector. Moreover, we derive an analytical expression for the corresponding detection threshold which depends on the statistics of the desired signal from the dedicated TX, the statistics of the MC channel, and the statistics of the ILI. Finally, we propose two new performance metrics, namely area rate efficiency (ARE) and area and time rate efficiency (ARTE), suitable for holistically evaluating spatially distributed multi-link MC systems. In particular, ARE and ARTE capture the tradeoff between transmission link density and achievable rate per link and the tradeoff between transmission link density, achievable rate per link, and inter-symbol interference (ISI), respectively. Hence, ARE and ARTE can be exploited to determine the optimal transmission link density for maximizing the throughput of the entire system.

cs.IT

Switchable Signaling Molecules for Media Modulation: Fundamentals, Applications, and Research Directions

Although visionary applications of molecular communication (MC), such as long-term continuous health monitoring by cooperative in-body nanomachines, have been proposed, MC is still in its infancy when it comes to practical implementation. In particular, long-term experiments and applications face issues such as depletion of signaling molecules (SMs) at the transmitter (TX) and inter-symbol interference (ISI) at the receiver (RX). To overcome these practical challenges, a new class of SMs with switchable states seems to be promising for future MC applications. In this work, we provide an overview of existing switchable SMs, and classify them according to their properties. Furthermore, we highlight how switchable SMs can be utilized as information carriers for media modulation. In addition, we present theoretical and experimental results for an end-to-end MC system employing the green fluorescent protein variant "Dreiklang" (GFPD) as switchable SM. Our experimental results show, for the first time, successful information transmission in a closed-loop pipe system using media modulation. Finally, we discuss media modulation specific challenges and opportunities.

cs.ET

Media Modulation based Molecular Communication

In conventional molecular communication (MC) systems, the signaling molecules used for information transmission are stored, released, and then replenished by a transmitter (TX). However, the replenishment of signaling molecules at the TX is challenging in practice. Furthermore, in most envisioned MC applications, e.g., in the medical field, it is not desirable to insert the TX into the MC system, as this might impair natural biological processes. In this paper, we propose the concept of media modulation based MC where the TX is placed outside the channel and utilizes signaling molecules already present inside the system. The signaling molecules can assume different states which can be switched by external stimuli. Hence, in media modulation based MC, the TX modulates information into the state of the signaling molecules. In particular, we exploit the group of photochromic molecules, which undergo light-induced reversible state transitions, for media modulation. We study the usage of these molecules for information transmission in a three-dimensional duct system, which contains an eraser, a TX, and a receiver for erasing, writing, and reading of information via external light, respectively. We develop a statistical model for the received signal which accounts for the distribution of the signaling molecules in the system, the initial states of the signaling molecules, the reliability of the state control mechanism, the randomness of irrepressible, spontaneous state switching, and the randomness of molecule propagation. We adopt a maximum likelihood detector and a threshold based detector. Furthermore, we derive analytical expressions for the optimal threshold value and the resulting bit error rate (BER), respectively. Our results reveal that media modulation enables reliable information transmission, validating it as a promising alternative to MC based on molecule emitting TXs.

q-bio.BM

Microparticle-based Controlled Drug Delivery Systems: From Experiments to Statistical Analysis and Design

Controlled drug delivery (CDD), the controlled release and delivery of therapeutic drugs inside the human body, is a promising approach to increase the efficacy of drug administration and reduce harmful side effects to the body. CDD has been a major research focus in the field of molecular communications (MC) with the goal to aid the design and optimization of CDD systems with communication theoretical analysis. However, the existing studies of CDD under the MC framework are purely theoretical, and the potential of MC for the development of practical CDD applications remains yet to be shown. This paper presents a step towards filling this research gap. Specifically, we present a novel MC-based model for a specific CDD system in which drugs are embedded into microparticles and released gradually towards the target site. It is demonstrated that the proposed model is able to faithfully reproduce experimental data. Furthermore, statistical analysis is conducted to explore the impact of the microparticle size on the drug release. The presented results reveal the sensitivity of the drug release to changes in the microparticle size. In this way, the proposed model can be used for the design of future microparticle-based CDD systems.

eess.SP

Stochastic Chemical Reaction Networks for MAP Detection in Cellular Receivers

In order to fully exploit the potential of molecular communication (MC) for intra-body communication, practically implementable cellular receivers are an important long-term goal. A variety of receiver architectures based on chemical reaction networks (CRNs) and gene-regulatory networks (GRNs) has been introduced in the literature, because cells use these concepts to perform computations in nature. However, practical feasibility is still limited by stochastic fluctuations of chemical reactions and long computation times in GRNs. Therefore, in this paper, we propose two receiver designs based on stochastic CRNs, i.e., CRNs that perform computations by exploiting the intrinsic fluctuations of chemical reactions with very low molecule counts. The first CRN builds on a recent result from chemistry that showed how Boltzmann machines (BMs), a commonly used machine learning model, can be implemented with CRNs. We show that BMs with optimal parameter values and their CRN implementations can act as maximum-a-posteriori (MAP) detectors. Furthermore, we show that BMs can be efficiently trained from simulation data to achieve close-to-MAP performance. While this approach yields a fixed CRN once deployed, our second approach based on a manually designed CRN can be trained with pilot symbols even within the cell and thus adapt to changing channel conditions. We extend the literature by showing that practical robust detectors can achieve close-to-MAP performance even without explicit channel knowledge.

cs.ET